Cardiac-gated spectroscopic photoacoustic imaging for ablation-induced necrotic lesion visualization

被引:1
|
作者
Gao, Shang [1 ]
Ashikaga, Hiroshi [2 ]
Suzuki, Masahito [2 ]
Mansi, Tommaso [3 ]
Kim, Young-Ho [3 ]
Ghesu, Florin-Cristian [3 ]
Kang, Jeeun [4 ,5 ]
Boctor, Emad M. [4 ,5 ]
Halperin, Henry R. [2 ]
Zhang, Haichong K. [1 ,6 ,7 ]
机构
[1] Worcester Polytech Inst, Dept Robot Engn, 100 Inst Rd, Worcester, MA 01609 USA
[2] Johns Hopkins Univ, Dept Med, Div Cardiol, Sch Med, Baltimore, MD USA
[3] Siemens Healthineers, Digital Technol & Innovat, Princeton, NJ USA
[4] Johns Hopkins Univ, Sch Med, Dept Radiol & Radiol Sci, Baltimore, MD USA
[5] Johns Hopkins Univ, Whiting Sch Engn, Lab Computat Sensing & Robot, Baltimore, MD USA
[6] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA USA
[7] Worcester Polytech Inst, Dept Comp Sci, Worcester, MA USA
基金
美国国家卫生研究院;
关键词
cardiac ablation; cardiac gating; image-guided intervention; in vivo demonstration; spectroscopic photoacoustic imaging; ATRIAL-FIBRILLATION; IN-VIVO; CONTACT FORCE; REAL-TIME; CATHETER; PLAQUES; TOMOGRAPHY; TUMORS;
D O I
10.1002/jbio.202400126
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Radiofrequency (RF) ablation is a minimally invasive therapy for atrial fibrillation. Conventional RF procedures lack intraoperative monitoring of ablation-induced necrosis, complicating assessment of completeness. While spectroscopic photoacoustic (sPA) imaging shows promise in distinguishing ablated tissue, multi-spectral imaging is challenging in vivo due to low imaging quality caused by motion. Here, we introduce a cardiac-gated sPA imaging (CG-sPA) framework to enhance image quality using a motion-gated averaging filter, relying on image similarity. Necrotic extent was calculated based on the ratio between spectral unmixed ablated tissue contrast and total tissue contrast, visualizing as a continuous color map to highlight necrotic area. The validation of the concept was conducted in both ex vivo and in vivo swine models. The ablation-induced necrotic lesion was successfully detected throughout the cardiac cycle through CG-sPA imaging. The results suggest the CG-sPA imaging framework has great potential to be incorporated into clinical workflow to guide ablation procedures intraoperatively. This study proposed a framework for spectroscopic PA imaging in the challenging setting of a beating heart, implementing cardiac gating based on image similarity to address tissue motion during the cardiac cycle and enhance imaging quality. We assess the feasibility of the method by identifying ablation-induced lesions through spectral analysis. The study demonstrates enhanced imaging quality and accurate assessment of ablation-induced necrotic lesions on the beating heart in both ex vivo and in vivo swine models.image
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Photoacoustic frequency analysis of the ablation-induced necrosis lesion
    Gao, Shang
    Murakami, Ryo
    Zhang, Haichong K.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2024, 2024, 12842
  • [2] Clinical Impact of Cardiac-Gated PET Imaging
    Nekolla, Stephan G.
    Dinges, Julia
    Rischpler, Christoph
    PET CLINICS, 2013, 8 (01) : 69 - +
  • [3] CARDIAC-GATED PHASE MR IMAGING OF AQUEDUCTAL CSF FLOW
    MASCALCHI, M
    CIRAOLO, L
    TANFANI, G
    TAVERNI, N
    INZITARI, D
    SIRACUSA, GF
    DALPOZZO, GC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (06) : 923 - 926
  • [4] CARDIAC-GATED LOCAL COIL MR IMAGING OF THE CAROTID NECK BIFURCATION
    DANIELS, DL
    KNEELAND, JB
    FOLEY, WD
    JESMANOWICZ, A
    FRONCISZ, W
    HYDE, JS
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1986, 7 (06) : 1036 - 1037
  • [5] Photoacoustic imaging in percutaneous radiofrequency ablation: device guidance and ablation visualization
    Francis, Kalloor Joseph
    Manohar, Srirang
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):
  • [6] Spectroscopic photoacoustic imaging of radiofrequency ablation in the left atrium
    Iskander-Rizk, Sophinese
    Kruizinga, Pieter
    van der Steen, Antonius F. W.
    van Soest, Gijs
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (03): : 1309 - 1322
  • [7] Development of cardiac-gated 3-dimensional ultrasound imaging of carotid atherosclerosis
    Mallett, C.
    Gardi, L.
    Pope, J.
    Spence, J.
    Fenster, A.
    Parraga, G.
    MEDICAL PHYSICS, 2007, 34 (06) : 2332 - 2332
  • [8] OPTIMIZING ELECTROCARDIOGRAPH ELECTRODE PLACEMENT FOR CARDIAC-GATED MAGNETIC-RESONANCE-IMAGING
    DIMICK, RN
    HEDLUND, LW
    HERFKENS, RJ
    FRAM, EK
    UTZ, J
    INVESTIGATIVE RADIOLOGY, 1987, 22 (01) : 17 - 22
  • [9] Four-Dimensional Image Reconstruction Strategies in Cardiac-Gated and Respiratory-Gated PET Imaging
    Rahmim, Arman
    Tang, Jing
    Zaidi, Habib
    PET CLINICS, 2013, 8 (01) : 51 - +
  • [10] Investigation of the pulsatility of cerebrospinal fluid using cardiac-gated Intravoxel Incoherent Motion imaging
    Becker, Anton S.
    Boss, Andreas
    Klarhoefer, Markus
    Finkenstaedt, Tim
    Wurnig, Moritz C.
    Rossi, Cristina
    NEUROIMAGE, 2018, 169 : 126 - 133