Incidence and predictors of vascular complications following transcatheter aortic valve implantation: A comparison of the MANTA and suture-based vascular closure devices

被引:0
|
作者
Sehgal, Kartik [1 ]
Butala, Anant D. [1 ]
Stub, Dion [1 ,2 ,3 ]
Palmer, Sonny [1 ,4 ]
Noaman, Samer [1 ]
Haji, Kawa [1 ]
Htun, Nay [1 ,2 ]
Johnston, Rozanne [1 ]
Walton, Antony [1 ,5 ]
Nanayakkara, Shane [1 ,2 ,5 ,6 ]
机构
[1] Alfred Hlth, Dept Cardiol, Melbourne, Vic, Australia
[2] Cabrini Hosp, Dept Cardiol, Melbourne, Vic, Australia
[3] Monash Univ, Sch Publ Hlth & Preventat Med, Melbourne, Vic, Australia
[4] Univ Melbourne, Dept Med, Melbourne, Vic, Australia
[5] Epworth Med Fdn, Dept Cardiol, Melbourne, Vic, Australia
[6] Monash Univ, Monash Alfred Baker Ctr Cardiovasc Res, Melbourne, Vic, Australia
关键词
aortic stenosis; transcatheter aortic valve implantation; vascular closure device; vascular complication; CLINICAL-OUTCOMES; ACCESS; MANAGEMENT; ANEMIA; IMPACT;
D O I
10.1002/ccd.31185
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundVascular complications post-transcatheter aortic valve implantation (TAVI) are common. Recent data regarding predictors of vascular complications are limited, particularly comparing newer plug-based devices versus traditional suture-based vascular closure devices (VCD).AimThe primary objective was to identify characteristics that predict a higher risk of vascular complications in TAVI patients, as judged by the VARC-3 criteria, specifically comparing risk factors between suture-based vs MANTA device closure.MethodsRetrospective analysis of patients who underwent TAVI between December 2019 and September 2023 was performed. Logistic regression and propensity score matching was performed to ascertain risk factors for vascular complications post-TAVI.ResultsOf the 1763 patients, there were 106 vascular complications (6%). There was a nonsignificant increased complication rate in MANTA vs suture-based device closure (8.3% vs 5.3%, p = 0.064). Among these, the most common complications were VCD failure (23%), pseudoaneurysm (20%) and arterial dissection (19%). Obesity (p = 0.021), anemia (p = 0.039) and MANTA device use (p = 0.027) were predictors of vascular complications. Within the MANTA cohort, novel oral anticoagulant (NOAC) use was predictive of vascular complications (p = 0.002). Among suture-based devices, obesity (p = 0.037) and anaemia (p = 0.017) were significant predictors. A propensity matched analysis derived 90 pairs of patients matched for age, gender, diabetes, peripheral arterial disease, NOAC use, anemia and obesity, identifying an average treatment effect of 0.039 (p = 0.04) when MANTA device closure was performed.ConclusionVascular complications in TAVI remain common. Identifying predictors such as MANTA device closure, obesity, anemia, and baseline NOAC use will allow for improved risk stratification and appropriate VCD selection in patients undergoing TAVI.
引用
收藏
页码:812 / 819
页数:8
相关论文
共 50 条
  • [1] Comparison of suture-based vascular closure devices in transfemoral transcatheter aortic valve implantation
    Barbanti, Marco
    Capranzano, Piera
    Ohno, Yohei
    Gulino, Simona
    Sgroi, Carmelo
    Imme, Sebastiano
    Tamburino, Claudia
    Cannata, Stefano
    Patane, Martina
    Di Stefano, Daniele
    Todaro, Denise
    Di Simone, Emanuela
    Deste, Wanda
    Gargiulo, Giuseppe
    Capodanno, Davide
    Grasso, Carmelo
    Tamburino, Corrado
    EUROINTERVENTION, 2015, 11 (06) : 690 - 697
  • [2] Clinical Research Vascular Complications in Transcatheter Aortic Valve Replacement With Plug-Based vs Suture-Based Closure Devices
    Zornitzki, Lior
    Zahler, David
    Frydman, Shir
    Itach, Tamar
    Ben-Shoshan, Jeremy
    Halkin, Amir
    Bazan, Samuel
    Arbel, Yaron
    Konigstein, Maayan
    Finkelstein, Ariel
    Banai, Shmuel
    Steinvil, Arie
    CANADIAN JOURNAL OF CARDIOLOGY, 2023, 39 (11) : 1528 - 1534
  • [3] MANTA versus ProGlide vascular closure devices in transfemoral transcatheter aortic valve implantation
    Biancari, Fausto
    Romppanen, Hannu
    Savontaus, Mikko
    Siljander, Antti
    Makikallio, Timo
    Piira, Olli-Pekka
    Piuhola, Jarkko
    Vilkki, Viivi
    Ylitalo, Antti
    Vasankari, Tuija
    Airaksinen, Juhani K. E.
    Niemela, Matti
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 263 : 29 - 31
  • [4] Clinical outcomes of MANTA vs suture-based vascular closure devices after transcatheter aortic valve replacement: An updated meta-analysis
    Doshi, Rajkumar
    Vasudev, Rahul
    Guragai, Nirmal
    Patel, Kunal Nitinkumar
    Kumar, Ashish
    Majmundar, Monil
    Doshi, Preet
    Patel, Prem
    Shah, Kalpesh
    Santana, Melvin
    Roman, Sherif
    Vallabhajosyula, Saraschandra
    Virk, Hartaj
    Bikkina, Mahesh
    Shamoon, Fayez
    INDIAN HEART JOURNAL, 2023, 75 (01) : 59 - 67
  • [5] Incidence and predictors of vascular access site complications following transfemoral transcatheter aortic valve implantation
    Fonseca, Paulo
    Almeida, Joao
    Bettencourt, Nuno
    Ferreira, Nuno
    Carvalho, Monica
    Ferreira, Wilson
    Caeiro, Daniel
    Goncalves, Helena
    Ribeiro, Jose
    Rodrigues, Alberto
    Braga, Pedro
    Gama, Vasco
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2017, 36 (10) : 747 - 753
  • [6] Vascular Complications Following Transcatheter Aortic Valve Implantation, Using MANTA (Collagen Plug-Based) versus PROSTAR (Suture-Based), from a French Single-Center Retrospective Registry
    Benic, Clement
    Nicol, Pierre Philippe
    Hannachi, Sinda
    Gilard, Martine
    Didier, Romain
    Nasr, Bahaa
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (20)
  • [7] Predictable Deployment of Suture-Based Vascular Closure Device Before Transfemoral Transcatheter Aortic Valve Replacement
    Leone, Pier Pasquale
    Scotti, Andrea
    Ludwig, Sebastian
    Sehatbakhsh, Samineh
    Assafin, Manaf
    Chau, Mei
    Spring, Alexander
    Montesino, Jesus
    Doolittle, James
    Granada, Juan F.
    Latib, Azeem
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : 485 - 486
  • [8] Comparison of Two Vascular Closure Device Strategies for Transfemoral Transcatheter Aortic Valve Replacement Using Suture-Based and Collagen-Plug-Based Techniques and Associated Vascular Complications
    Yunus, Raza
    Alzahrani, Talal
    Taoutel, Roy
    Reiner, Jonathan
    Mazhari, Ramesh
    Najam, Farzad
    Trachiotis, Gregory D.
    Krepp, Joseph
    Choi, Andrew
    Sarin, Shawn
    Nagy, Christian D.
    JOURNAL OF INVASIVE CARDIOLOGY, 2025, 37 (03):
  • [9] Comparison of MANTA versus Perclose Prostyle large-bore vascular closure devices during transcatheter aortic valve implantation
    Barbash, Israel M.
    Wasserstrum, Yishay
    Erlebach, Magdalena
    Guetta, Victor
    Ziegelmueller, Johannes
    Segev, Amit
    Fefer, Paul
    Maor, Elad
    Lange, Ruediger
    Ruge, Hendrik
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 103 (01) : 160 - 168
  • [10] Management of vascular complications following transcatheter aortic valve implantation
    Perrin, Nils
    Ellenberger, Christoph
    Licker, Marc
    Hachulla, Anne-Lise
    Cikirikcioglu, Mustafa
    Frei, Angela
    Roffi, Marco
    Noble, Stephane
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2015, 108 (10) : 491 - 501