Delayed Right Ventricular Automatic Implantable Cardioverter Defibrillator (AICD) Lead Perforation Resulting in Cardiac Tamponade: A Case Study

被引:0
|
作者
Hubert, James [1 ]
Irvine, Dylan S. [1 ]
Thornton, Imani [2 ]
机构
[1] HCA Florida Westside Hosp, Anesthesiol, Plantation, FL 33324 USA
[2] HCA Florida Westside Hosp, Anesthesiol & Crit Care, Plantation, FL USA
关键词
anesthesia considerations; critical care and hospital medicine; pacemaker lead perforation; automated implantable cardiac defibrillator (aicd); anesthesiology practice;
D O I
10.7759/cureus.68996
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Automatic implantable cardioverter defibrillator (AICD) lead perforation is a rare but potentially lifethreatening complication. AICD lead perforations are rare, occurring in approximately 0.1%-0.8% of patients, most commonly within 24 hours of the implantation. ICD lead perforations can be acute (within 24 hours of implantation), subacute (between day 1 and day 30), or delayed (>30 days postimplantation). Delayed lead perforations are rare compared to acute and subacute lead perforations and are not as wellstudied because patients are often asymptomatic and are not diagnosed. Here, we report the case of a 44year-old male who presented to the emergency department with pleuritic chest pain and dyspnea onemonth status-post dual-chamber AICD. The patient demonstrated signs and symptoms of cardiac tamponade, which was confirmed with a 2D echocardiogram and computed tomography (CT) scans. Emergency pericardiocentesis was performed under general anesthesia, which restored hemodynamic stability. The right ventricular lead was repositioned and a pericardial drain was placed. The patient remained in the intensive care unit (ICU) for three days and was discharged to home on postoperative day 8.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Delayed Right Ventricular Perforation in Patient with Implantable Cardioverter - Defibrillator
    Fagundes, Alexsandro Alves
    de Magalhaes, Luiz Pereira
    Pinheiro, Jussara
    Flausino, Leonardo
    Souza, Luciano Rapold
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2010, 95 (06) : E147 - E149
  • [2] Right Ventricular Free Wall Rupture Due to Displaced Automatic Implantable Cardioverter Defibrillator (AICD) Lead
    Rao, Abhinav K.
    Herrforth, Craig
    Patel, Angeli
    Patel, Kunaal
    Lyons, Brittany
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [3] Management of Subacute and Delayed Right Ventricular Perforation With a Pacing or an Implantable Cardioverter-Defibrillator Lead
    Laborderie, Julien
    Barandon, Laurent
    Ploux, Sylvain
    Deplagne, Antoine
    Mokrani, Bilel
    Reuter, Sylvain
    Le Gal, Francois
    Jais, Pierre
    Haissaguerre, Michel
    Clementy, Jacques
    Bordachar, Pierre
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (10): : 1352 - 1355
  • [4] A CASE OF LATE RIGHT VENTRICULAR PERFORATION BY AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    Sharedalal, Parija
    Ediae, Jude
    Kutalek, Steven
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 2596 - 2596
  • [5] Cardiac computed tomography for the diagnosis of right ventricular implantable cardioverter-defibrillator lead perforation
    der Maur, Christoph Auf
    Hoffmann, Alexander
    Brink, Tom
    Erne, Paul
    EUROPEAN HEART JOURNAL, 2009, 30 (07) : 869 - 869
  • [6] Automatic Implantable Cardioverter Defibrillator Lead Dislodgement Resulting in Sudden Cardiac Death: A Case Report
    Nair, Girish M.
    Nair, Vidhya
    Healey, Jeffrey S.
    Morillo, Carlos A.
    CANADIAN JOURNAL OF CARDIOLOGY, 2014, 30 (11) : 1460.e7 - 1460.e9
  • [7] Gemella haemolysans: Rare case of automatic implantable cardioverter-defibrillator (AICD) lead infection
    Kriege, Kevin
    Wilson, Brycen
    Tate, Joshua
    SAGE OPEN MEDICAL CASE REPORTS, 2022, 10
  • [8] Asymptomatic right ventricular perforation by an implantable cardioverter defibrillator lead detected by home monitoring system
    Migliore, Federico
    Leoni, Loira
    Torregrossa, Gianluca
    Guglielmi, Cosimo
    Tarantini, Giuseppe
    Buja, Gianfranco
    Iliceto, Sabino
    Corrado, Domenico
    JOURNAL OF ELECTROCARDIOLOGY, 2010, 43 (06) : 673 - 675
  • [9] THE ROLE OF THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (AICD) IN THE TREATMENT OF MEDICALLY REFRACTORY VENTRICULAR ARRHYTHMIAS
    FERGUSON, TB
    TRENDS IN CARDIOVASCULAR MEDICINE, 1991, 1 (03) : 131 - 139
  • [10] Delayed Right Ventricular Perforation by a Transvenous Active Fixation Implantable Cardioverter-Defibrillator Lead Echocardiographic Diagnosis and Surgical Management
    Ferrero-de-Loma-Osorio, Angel
    Albors-Martin, Jose
    Ruiz-Granell, Ricardo
    Dominguez-Mafe, Eloy
    Angel Bahamonde-Romano, Jose
    Palau-Sampio, Patricia
    Boix-Garibo, Ricardo
    CIRCULATION, 2009, 119 (15) : 2112 - 2113