Cardiorespiratory motion characteristics and their dosimetric impact on cardiac stereotactic body radiotherapy

被引:2
|
作者
Li, Guangjun [1 ,2 ]
Wang, Guangyu [3 ]
Wei, Weige [1 ,2 ]
Li, Zhibin [4 ]
Xiao, Qing [1 ,2 ]
He, Haiping [1 ,2 ]
Luo, Dashuang [1 ,2 ]
Chen, Li [5 ]
Li, Jing [1 ,2 ]
Zhang, Xiangyu [1 ,2 ]
Song, Ying [1 ,2 ]
Bai, Sen [1 ,2 ]
机构
[1] Sichuan Univ, West China Hosp, Canc Ctr, Dept Radiat Oncol, 37 Guoxue Alley, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Radiotherapy Phys & Technol, Chengdu, Sichuan, Peoples R China
[3] Sun Yat Sen Univ, Guangdong Prov Clin Res Ctr Canc, Canc Ctr, State Key Lab Oncol South China, Guangzhou, Peoples R China
[4] Soochow Univ, Affiliated Hosp 1, Inst Radiotherapy & Oncol, Dept Radiotherapy & Oncol, Suzhou, Peoples R China
[5] Soochow Univ, Affiliated Hosp 2, Dept Radiotherapy & Oncol, Suzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
4D cardiac computed tomography; 4D dose reconstruction; cardiac pulsation; refractory arrhythmias; stereotactic body radiotherapy; MODULATED ARC THERAPY; IMAGE REGISTRATION; RADIATION-THERAPY; RESPIRATORY MOTION; NONRIGID REGISTRATION; BREATHING MOTION; DOSE CALCULATION; ACUROS XB; LUNG; INTERPLAY;
D O I
10.1002/mp.17284
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Cardiac stereotactic body radiotherapy (CSBRT) is an emerging and promising noninvasive technique for treating refractory arrhythmias utilizing highly precise, single or limited-fraction high-dose irradiations. This method promises to revolutionize the treatment of cardiac conditions by delivering targeted therapy with minimal exposure to surrounding healthy tissues. However, the dynamic nature of cardiorespiratory motion poses significant challenges to the precise delivery of dose in CSBRT, introducing potential variabilities that can impact treatment efficacy. The complexities of the influence of cardiorespiratory motion on dose distribution are compounded by interplay and blurring effects, introducing additional layers of dose uncertainty. These effects, critical to the understanding and improvement of the accuracy of CSBRT, remain unexplored, presenting a gap in current clinical literature. Purpose: To investigate the cardiorespiratory motion characteristics in arrhythmia patients and the dosimetric impact of interplay and blurring effects induced by cardiorespiratory motion on CSBRT plan quality. Methods: The position and volume variations in the substrate target and cardiac substructures were evaluated in 12 arrhythmia patients using displacement maximum (DMX) and volume metrics. Moreover, a four-dimensional (4D) dose reconstruction approach was employed to examine the dose uncertainty of the cardiorespiratory motion. Results: Cardiac pulsation induced lower DMX than respiratory motion but increased the coefficient of variation and relative range in cardiac substructure volumes. The mean DMX of the substrate target was 0.52 cm (range: 0.26-0.80 cm) for cardiac pulsation and 0.82 cm (range: 0.32-2.05 cm) for respiratory motion. The mean DMX of the cardiac structure ranged from 0.15 to 1.56 cm during cardiac pulsation and from 0.35 to 1.89 cm during respiratory motion. Cardiac pulsation resulted in an average deviation of -0.73% (range: -4.01%-4.47%) in V-25 between the 3D and 4D doses. The mean deviations in the homogeneity index (HI) and gradient index (GI) were 1.70% (range: -3.10%-4.36%) and 0.03 (range: -0.14-0.11), respectively. For cardiac substructures, the deviations in D-50 due to cardiac pulsation ranged from -1.88% to 1.44%, whereas the deviations in D-max ranged from -2.96% to 0.88% of the prescription dose. By contrast, the respiratory motion led to a mean deviation of -1.50% (range: -10.73%-4.23%) in V-25. The mean deviations in HI and GI due to respiratory motion were 4.43% (range: -3.89%-13.98%) and 0.18 (range: -0.01-0.47) (p < 0.05), respectively. Furthermore, the deviations in D-50 and D-max in cardiac substructures for the respiratory motion ranged from -0.28% to 4.24% and -4.12% to 1.16%, respectively. Conclusions: Cardiorespiratory motion characteristics vary among patients, with the respiratory motion being more significant. The intricate cardiorespiratory motion characteristics and CSBRT plan complexity can induce substantial dose uncertainty. Therefore, assessing individual motion characteristics and 4D dose reconstruction techniques is critical for implementing CSBRT without compromising efficacy and safety.
引用
收藏
页码:8551 / 8567
页数:17
相关论文
共 50 条
  • [1] Dosimetric Impact of Esophagus Motion in Spine Stereotactic Body Radiotherapy
    Yang, J.
    Wang, X.
    Zhao, Z.
    Yang, J.
    Zhang, Y.
    Court, L.
    Li, J.
    Brown, P.
    Ghia, A.
    MEDICAL PHYSICS, 2016, 43 (06) : 3436 - 3436
  • [2] Dosimetric impact of esophagus motion in single fraction spine stereotactic body radiotherapy
    Wang, Xin
    Yang, Jinzhong
    Zhao, Zhongxiang
    Luo, Dershan
    Court, Laurence
    Zhang, Yongbin
    Weksberg, David
    Brown, Paul D.
    Li, Jing
    Ghia, Amol J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (11):
  • [3] The impact of emphysema on dosimetric parameters for stereotactic body radiotherapy of the lung
    Ochiai, Satoru
    Nomoto, Yoshihito
    Yamashita, Yasufumi
    Inoue, Tomoki
    Murashima, Shuuichi
    Hasegawa, Daisuke
    Kurita, Yoshie
    Watanabe, Yui
    Toyomasu, Yutaka
    Kawamura, Tomoko
    Takada, Akinori
    Ii, Noriko
    Kobayashi, Shigeki
    Sakuma, Hajime
    JOURNAL OF RADIATION RESEARCH, 2016, 57 (05) : 555 - 566
  • [4] Dosimetric impact of the respiratory motion of the liver dome in stereotactic body radiotherapy for spine metastasis: A planning study
    Okamoto, Hiroyuki
    Nonaka, Midori
    Chiba, Takahito
    Kaneda, Tomoya
    Kobayashi, Yuta
    Nakamura, Satoshi
    Nakayama, Hiroki
    Iijima, Kotaro
    Shuto, Yasunori
    Yonemura, Miki
    Oshika, Riki
    Kishida, Hironori
    Urago, Yuka
    Nishitani, Masato
    Nishina, Shuka
    Sakamoto, Takumi
    Shibata, Yoshihiro
    Goka, Tomonori
    Igaki, Hiroshi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [5] Dosimetric Impact of Intra-fraction Motion on Image Guided Stereotactic Body Radiotherapy of Spinal Metastasis
    Le, Y.
    Tryggestad, E.
    Ford, E.
    McNutt, T.
    Kleinberg, L.
    Lim, M.
    Rigamonti, D.
    Wong, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S689 - S689
  • [6] Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy
    Zhao, Bo
    Yang, Yong
    Li, Tianfang
    Li, Xiang
    Heron, Dwight E.
    Huq, M. Saiful
    MEDICAL PHYSICS, 2012, 39 (11) : 6629 - 6637
  • [7] The dosimetric impact of implants on the spinal cord dose during stereotactic body radiotherapy
    Gozde Yazici
    Sezin Yuce Sari
    Fazli Yagiz Yedekci
    Altug Yucekul
    Sumerya Duru Birgi
    Gokhan Demirkiran
    Melis Gultekin
    Pervin Hurmuz
    Muharrem Yazici
    Gokhan Ozyigit
    Mustafa Cengiz
    Radiation Oncology, 11
  • [8] Dosimetric impact of a change in breathing period on VMAT stereotactic ablative body radiotherapy
    Olding, T.
    Alexander, K. M.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [9] The dosimetric impact of implants on the spinal cord dose during stereotactic body radiotherapy
    Yazici, Gozde
    Sari, Sezin Yuce
    Yedekci, Fazli Yagiz
    Yucekul, Altug
    Birgi, Sumerya Duru
    Demirkiran, Gokhan
    Gultekin, Melis
    Hurmuz, Pervin
    Yazici, Muharrem
    Ozyigit, Gokhan
    Cengiz, Mustafa
    RADIATION ONCOLOGY, 2016, 11
  • [10] Quantifying dose uncertainties resulting from cardiorespiratory motion in intensity-modulated proton therapy for cardiac stereotactic body radiotherapy
    Wei, Weige
    Li, Zhibin
    Xiao, Qing
    Wang, Guangyu
    He, Haiping
    Luo, Dashuang
    Chen, Li
    Li, Jing
    Zhang, Xiangyu
    Qin, Taolin
    Song, Ying
    Li, Guangjun
    Bai, Sen
    FRONTIERS IN ONCOLOGY, 2024, 14