Improving the transfer of dissolved oxygen in a biological Fe2+ oxidation process using a venturi jet as an intensive aeration system

被引:0
|
作者
Morell, Joan [1 ]
Guimera, Xavier [1 ]
Dorado, Antonio David [1 ]
机构
[1] Univ Politecn Catalunya UPC, Manresa Sch Engn EPSEM, Dept Min Ind & ICT Engn EMIT, Ave Bases Manresa 61-73, Manresa 08242, Spain
关键词
Venturi jet; Diffuser; Dissolved oxygen concentration; Ferrous oxidation rate; acidithiobacillus ferrooxidans; FERROUS IRON OXIDATION; IMMOBILIZED ACIDITHIOBACILLUS-FERROOXIDANS; THIOBACILLUS-FERROOXIDANS; COTTON GAUZE; WASTE; BIOOXIDATION; RECOVERY; BIOFILM; IONS; PVA;
D O I
10.1016/j.hydromet.2024.106380
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The low bio-production of Fe3+ as a leaching agent is one of the main limitations to implementing industrial bioprocesses at feasibility conditions. The main limitation of the bio-oxidation process of Fe2+ is the low oxygen transfer to the aqueous phase because of the low oxygen solubility. This study assesses the effectiveness of the venturi jet as an innovative and intensive aeration device for overcoming the oxygen limitation in a continuous ferrous oxidation process in a fixed-bed reactor with immobilized acidithiobacillus ferrooxidans, in contrast to the conventional diffuser aeration device. Firstly, the influence of the airflow and the influence of the medium concentration were determined for the following parameters for both aeration devices; Volumetric mass transfer coefficient (kLa), Standard Oxygen Transfer Rate (SOTR), Standard Aeration Efficiency (SAE), and Standard Oxygen Transfer Efficiency (SOTE). Then, both aeration devices were compared in a continuous bio-oxidation process in an up-flow packed bio-reactor (UFPB). The system performance was assessed by monitoring temperature, pH, oxidation-reduction potential, and dissolved oxygen concentration for 69 days. Findings displayed that when aerating with the diffuser, the ferrous oxidation rate was restricted by the low dissolved oxygen availability, being about 1 ppm (1 mg L- 1). Under these oxygen-limiting conditions, the maximum ferrous (Fe2+) oxidation rate was 9.09 g L- 1 h- 1. However, when aerating with the venturi jet, the dissolved oxygen concentration increased up to 2.70 mg L- 1, achieving a maximum of 29.11 g L- 1 h- 1. So, this study has demonstrated that the change in the aeration device has resulted in an improvement in the process, achieving a 3.5-fold increase in the oxidation rate. Furthermore, the venturi jet offered additional advantages over the diffuser, such as requiring less power to deliver the same amount of air, being unaffected by jarosite precipitates, and not requiring a supply of compressed air.
引用
收藏
页数:10
相关论文
共 19 条
  • [1] Baicalin Inhibits the Fenton Reaction by Enhancing Electron Transfer from Fe2+ to Dissolved Oxygen
    Nishizaki, Daisuke
    Iwahashi, Hideo
    AMERICAN JOURNAL OF CHINESE MEDICINE, 2015, 43 (01): : 87 - 101
  • [2] THE HETEROGENEOUS OXIDATION-KINETICS OF FE2+ AND MN2+ AS FOLLOWED BY DISSOLVED-OXYGEN CONSUMPTION
    MACHESKY, ML
    KILGORE, SH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 68 - GEOC
  • [3] Feasibility of an electrochemically assisted Fenton method using Fe2+/HOCl system as an advanced oxidation process
    Kishimoto, N.
    Sugimura, E.
    WATER SCIENCE AND TECHNOLOGY, 2010, 62 (10) : 2321 - 2329
  • [4] Electrochemically assisted Fenton process using Fe2+/HOCI system for the treatment of landfill leachate
    Ye, Zhihong
    Wang, Zhe
    Zhang, Hui
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [5] Accelerated Fe3+/Fe2+ cycle using atomic H* on Pd/Al2O3: A novel mechanism for an electrochemical system with particle electrode for iron sludge reduction in the Fe2+/peroxydisulfate oxidation process
    Zeng, Huabin
    Zhao, Xu
    Zhao, Feiping
    Park, Yuri
    Sillanpaa, Mika
    CHEMICAL ENGINEERING JOURNAL, 2020, 382 (382)
  • [6] A facile method for efficient synergistic oxidation of Fe2+ in phosphorus-sulfur mixed acid system with a mixture of oxygen and ozone
    Dong-yan Liu
    Wen-bo Lou
    Shi-neng Sun
    Yang Zhang
    Ying Zhang
    Shi-li Zheng
    Korean Journal of Chemical Engineering, 2022, 39 : 3323 - 3333
  • [7] A facile method for efficient synergistic oxidation of Fe2+ in phosphorus-sulfur mixed acid system with a mixture of oxygen and ozone
    Liu, Dong-yan
    Lou, Wen-bo
    Sun, Shi-neng
    Zhang, Yang
    Zhang, Ying
    Zheng, Shi-li
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2022, 39 (12) : 3323 - 3333
  • [8] Coupled photo-Fenton-biological system: effect of the Fenton parameters such as residual H2O2, Fe2+ and pH on the efficiency of biological process
    Mosteo, Rosa
    Gumy, Damien
    Pulgarin, Cesar
    WATER SCIENCE AND TECHNOLOGY, 2008, 58 (08) : 1679 - 1685
  • [9] Elemental mercury removal from flue gas using heat and Co2+/Fe2+ coactivated oxone oxidation system
    Liu, Yangxian (liuyx1984@126.com), 1600, Elsevier B.V. (348):
  • [10] Elemental mercury removal from flue gas using heat and Co2+/Fe2+ coactivated oxone oxidation system
    Liu, Yangxian
    Wang, Yan
    CHEMICAL ENGINEERING JOURNAL, 2018, 348 : 464 - 475