Effect of intrastromal corneal ring segments on in vivo corneal biomechanics in keratoconus: 1-year results

被引:0
|
作者
Vinciguerra, Riccardo [1 ,2 ]
Fernandez-Vega-Cueto, Luis [2 ,3 ]
Roberts, Cynthia J. [4 ]
Poo-Lopez, Arancha [2 ,3 ]
Eliasy, Ashkan [5 ]
Merayo-Lloves, Jesus [2 ,3 ]
Elsheikh, Ahmed [5 ,6 ,7 ,8 ]
Madrid-Costa, David [3 ]
Lisa, Carlos [2 ,3 ]
Alfonso, Jose F. [2 ,3 ]
机构
[1] Human San Pio X Hosp, Via Francesco Nava 31, Milan, Italy
[2] Univ Oviedo, Sch Med, Surg Dept, Asturias, Spain
[3] Fernandez Vega Ophthalmol Inst, Oviedo, Spain
[4] Ohio State Univ, Dept Ophthalmol & Visual Sci, Dept Biomed Engn, Columbus, OH USA
[5] Univ Liverpool, Sch Engn, Liverpool, England
[6] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Beijing, Peoples R China
[7] Moorfields Eye Hosp NHS Fdn Trust, Biomed Res Ctr Ophthalmol, London, England
[8] UCL Inst Ophthalmol, London, England
来源
关键词
COLLAGEN CROSS-LINKING; PROGRESSIVE KERATOCONUS; IMPLANTATION; PARAMETERS;
D O I
10.1097/j.jcrs.0000000000001298
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the 1-year effects of the implantation of intrastromal corneal ring segments (ICRS) in keratoconus (KC) on the dynamic corneal response (DCR) parameters obtained with the Corvis. Setting: Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design: Prospective, single-center, clinical study. Methods: Included were patients who underwent ICRS implantation for KC over a period of 1 year. On the day of the surgery and at least 6 months after ICRS implantation, the following measurements were made: corrected distance and uncorrected distance visual acuity, corneal tomography indices with the Pentacam, biomechanically corrected intraocular pressure and the Corvis DCRs (integrated inverse concave radius, deformation amplitude ratio, stiffness parameter at first applanation, stress-strain index [SSI] and the highest concavity radius). Results: 30 eyes were included with a mean follow-up time of 15 months. Statistical analysis showed that ICRS implantation induced significant improvements in corneal biomechanics measurements between preoperative and long-term follow-up as demonstrated by a significant increase in SSI (P = .003). To confirm that this difference was actually induced due to a stiffening between early postoperative (previously published) and long-term an additional t-test was done between month 1 and late follow-up which confirmed a significant stiffening in the value of SSI (P = .01). Conclusions: Patients implanted with ICRS alone for KC showed a significantly stiffer response due to increased structural support compared with preoperative values and 1 month postoperative.
引用
收藏
页码:1258 / 1263
页数:6
相关论文
共 50 条
  • [1] Intrastromal corneal ring segments for keratoconus: results and correlation with preoperative corneal biomechanics
    Ambrosio, Renato, Jr.
    Borges, Jose Salgado
    Costa-Ferreira, Claudia
    Coelho, Vinicius
    da Silva, Renata Siqueira
    Valbon, Bruno
    Siqueira, Jorge Augusto
    Velarde, Guillermo Coca
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (02) : 89 - 99
  • [2] Additional Intrastromal Corneal Ring Segments in Keratoconus
    Hashemi, Hassan
    Nabavi, Amin
    Bayat, Reza
    Mohebbi, Masoumeh
    CORNEA, 2018, 37 (05) : 574 - 579
  • [3] Intrastromal corneal ring segments for management of keratoconus
    Ganesh, Sri
    Shetty, Rohit
    D'Souza, Sharon
    Ramachandran, Sarika
    Kurian, Mathew
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (08) : 451 - 455
  • [4] Intrastromal corneal ring segments for treating keratoconus
    Zadnik, Karla
    Money, Sarah
    Lindsley, Kristina
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (05):
  • [5] Intrastromal corneal ring segments delay corneal grafting in patients with keratoconus
    Beniz, Luiz Arthur F.
    Queiroz, Gustavo H.
    Queiroz, Carlos F.
    Lopes, Wanessa L.
    Moraes, Leiser F.
    Beniz, Jose
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2016, 79 (01) : 30 - 32
  • [6] Combination of corneal crosslinking and intrastromal corneal ring segments for the treatment of keratoconus
    Zhang, Zhen-Yong
    Zhang, Xing-Ru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10): : 1878 - 1879
  • [7] Tonometry after Intrastromal Corneal Ring Segments for Keratoconus
    Arribas-Pardo, Paula
    Mendez-Hernandez, Carmen
    Cuina-Sardina, Ricardo
    Manuel Benitez-del-Castillo, Jose
    Garcia-Feijoo, Julian
    OPTOMETRY AND VISION SCIENCE, 2017, 94 (10) : 986 - 992
  • [8] KeraRing Intrastromal Corneal Ring Segments for Correction of Keratoconus
    Gharaibeh, Almutez M.
    Muhsen, Sana' M.
    AbuKhader, Ilham B.
    Ababneh, Osama H.
    Abu-Ameerh, Mohammed A.
    Albdour, Muawyah D.
    CORNEA, 2012, 31 (02) : 115 - 120
  • [9] Ferrara intrastromal corneal ring segments for severe keratoconus
    Miranda, D
    Sartori, M
    Francesconi, C
    Allemann, N
    Ferrara, P
    Campos, M
    JOURNAL OF REFRACTIVE SURGERY, 2003, 19 (06) : 645 - 653
  • [10] Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus
    Dauwe, Caroline
    Touboul, David
    Roberts, Cynthia J.
    Mahmoud, Ashraf M.
    Kerautret, Julien
    Fournier, Pierre
    Malecaze, Francois
    Colin, Joseph
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10): : 1761 - 1767