Patient-Specific Dosimetry Evaluations in Theranostics Software for Internal Radiotherapy

被引:0
|
作者
Grassi, Elisa [1 ]
Finocchiaro, Domenico [2 ]
Fioroni, Federica [1 ]
Andl, George [3 ]
Filice, Angelina [4 ]
Versari, Annibale [4 ]
El Ouati, Ayman [5 ]
Spezi, Emiliano [6 ]
Iori, Mauro [1 ]
机构
[1] Azienda USL IRCCS Reggio Emilia, Med Phys Unit, I-42123 Reggio Emilia, Italy
[2] Univ Hosp Modena, Med Phys Unit, I-41124 Modena, Italy
[3] Varian Med Syst Inc, 3100 Hansen Way, Palo Alto, CA 94304 USA
[4] Azienda USL IRCCS Reggio Emilia, Nucl Med Unit, I-42123 Reggio Emilia, Italy
[5] Univ Modena & Reggio Emilia, Dept Phys, I-41125 Modena, Italy
[6] Cardiff Univ, Sch Engn, Cardiff CF24 3AA, Wales
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 16期
关键词
internal radiotherapy; dosimetry; Lu-177; theranostics; software; QUALITY-ASSURANCE; THERAPY; VALIDATION;
D O I
10.3390/app14167345
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In Internal Radiotherapy, radiopharmaceutical dosimetry provides an accurate estimation of absorbed radiation doses to organs at risk and tumours. In this paper Velocity Theranostics (Varian Medical Systems), is investigated. Its performances are compared to OLINDA 2.0 in both an anthropomorphic phantom and a group of patients. Velocity Theranostics was evaluated with a cohort of patients (15) treated with Lu-177 radiolabelled peptides. The absorbed doses were calculated for the liver, spleen and kidneys, separately with OLINDA 2.0 and Velocity Theranostics using the same set of images. To reduce the contribution of Time-integrated activities (TIAs) on the results and to merely compare the dose calculation algorithms, the OLINDA 2.0 absorbed doses were calculated using the TIA values calculated in Velocity Theranostics. The absorbed doses from Velocity Theranostics were found to be correlated with the doses from OLINDA 2.0 with the TIAs from Theranostics (Lin's coefficient = 0.894 and R-2 = 0.9531). Absorbed doses from Velocity Theranostics are reliable at least as reliable as those for OLINDA 2.0, with many advantages regarding accuracy of calculations and robustness. In conclusion, the personalisation of dosimetry may be totally fulfilled by computational systems for absorbed dose in internal radiotherapy, equipped with a complete workflow and borrowed from external radiotherapy.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Theranostics and Patient-Specific Dosimetry
    Bednarz, Bryan
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2023, 33 (03) : 317 - 326
  • [2] Patient-specific internal radionuclide dosimetry
    Tsougos, Ioannis
    Loudos, George
    Georgoulias, Panagiotis
    Theodorou, Kiki
    Kappas, Constantin
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (02) : 97 - 106
  • [3] Future trends for patient-specific dosimetry methodology in molecular radiotherapy
    Gustafsson, Johan
    Taprogge, Jan
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 115
  • [4] Evaluation of a patient-specific Monte Carlo software for CT dosimetry
    Myronakis, Marios
    Perisinakis, Kostas
    Tzedakis, Antonis
    Gourtsoyianni, Sofia
    Damilakis, John
    [J]. RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 248 - 255
  • [5] Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance
    Narayanasamy, Ganesh
    Zalman, Travis
    Ha, Chul S.
    Papanikolaou, Niko
    Stathakis, Sotirios
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 329 - 338
  • [6] Implementation and evaluation of patient-specific three-dimensional internal dosimetry
    Kolbert, KS
    Sgouros, G
    Scott, AM
    Bronstein, JE
    Malane, RA
    Zhang, JJ
    Kalaigian, H
    McNamara, S
    Schwartz, L
    Larson, SM
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (02) : 301 - 308
  • [7] Patient-Specific Alpha Particle Dosimetry Using Radiopharmaceutical Assessment Platform for Internal Dosimetry (RAPID)
    Marsh, I. R.
    Besemer, A. E.
    Bednarz, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E699 - E699
  • [8] Development of Image-Based Patient-Specific Dosimetry Technique for Internal Radiotherapy (IRT) for Neuroendocrine Tumours: A Preliminary Report
    Birkenfeld, B.
    Listewnik, M. H.
    Zorga, P.
    Piwowarska-Bilska, H.
    Grimes, J.
    Shcherbinin, S.
    Celler, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S429 - S429
  • [9] PATIENT-SPECIFIC DOSIMETRY IN RADIONUCLIDE THERAPY
    Lyra, Maria
    Lagopati, Nefeli
    Charalambatou, Paraskevi
    Vamvakas, Ioannis
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 258 - 263
  • [10] Patient-Specific Dosimetry for Photodynamic Therapy
    Finlay, Jarod C.
    Li, Jun
    Zhou, Xiaodong
    Zhu, Timothy C.
    [J]. PROCEEDINGS OF LIGHT-ACTIVATED TISSUE REGENERATION AND THERAPY CONFERENCE, 2008, 12 : 115 - +