A training centre for intraocular pressure metrology

被引:0
|
作者
Prazak, Dominik [1 ]
Suchy, Vitezslav [1 ]
Safarikova-Pstroszova, Marketa [1 ,2 ]
Drbalkova, Katerina [1 ,2 ]
Sedlak, Vaclav [1 ,2 ]
Alisic, Sejla [3 ]
Bescupscii, Anatolii [4 ]
Kacarski, Vanco [5 ]
机构
[1] Czech Metrol Inst, Okruzni 31, Brno 63800, Czech Republic
[2] Slovak Univ Technol Bratislava, Fac Mech Engn, Bratislava 81231, Slovakia
[3] Inst Mjeriteljstvo Bosne & Hercegovine, Branilaca Sarajeva 25, Sarajevo 71000, Bosnia & Herceg
[4] IP Inst Natl Metrol, Eugen Coca 28, Kishinev 2064, Moldova
[5] Bur Metrol, Bull Jane Sandanski 109a, Skopje 1000, North Macedonia
来源
ACTA IMEKO | 2022年 / 11卷 / 04期
关键词
Training centre; metrological traceability; eye-tonometer; intraocular pressure; TONOMETERS; STANDARDS; GLAUCOMA; APPLANATION; QUALITY; CORNEA;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The eye-tonometers are the important medical devices with measuring function which are necessary for the screenings of the intraocular hypertension (a serious risk factor for the glaucoma). However, it is not an easy task to ensure their correct metrological traceability. There is needed not only a wide range of various equipment but also the relevant know-how. Hence, a training centre for this quantity was established at the Czech Metrology Institute (CMI) within the framework of a smart specialisation concept for the intraocular pressure (IOP) metrology. The paper briefly outlines its history, scope, methodologies and future development plans.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Mindfulness Training reduces Intraocular Pressure in Glaucoma
    Wiebrecht, Axel
    DEUTSCHE ZEITSCHRIFT FUR AKUPUNKTUR, 2019, 62 (02): : 145 - 145
  • [2] Effects Of Resistance Training And High-intensity Interval Training On Intraocular Pressure
    Conte, Marcelo
    Ciolac, Emmanuel Gomes
    Rosa, Morgana Rabelo
    Cozza, Heitor
    Caldara, Andre Athanazio
    Storti, Lucas Ruiz
    Baldin, Alexandre Duarte
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 98 - 99
  • [3] Influence of the breathing pattern during resistance training on intraocular pressure
    Vera, Jesus
    Perez-castilla, Alejandro
    Redondo, Beatriz
    Carlos De La Cruz, Juan
    Jimenez, Raimundo
    Garcia-Ramos, Amador
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2020, 20 (02) : 157 - 165
  • [4] Effect of the level of effort during resistance training on intraocular pressure
    Vera, Jesus
    Jimenez, Raimundo
    Redondo, Beatriz
    Torrejon, Alejandro
    De Moraes, Carlos Gustavo
    Garcia-Ramos, Amador
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2019, 19 (03) : 394 - 401
  • [5] Intraocular pressure variation after submaximal strength test in resistance training
    Conte, Marcelo
    Scarpi, Marinho Jorge
    Rossin, Reginaldo Alexandre
    Beteli, Helio Rubens
    Lopes, Rodrigo Gustavo
    Marcos, Haroldo Leao
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (03) : 351 - 354
  • [6] Exercise Training Reverses Blood and Intraocular Pressure in Rats With Metabolic Disturbances
    Castro, Emerson F., Sr.
    Ferreira, Domingos M.
    Mostarda, Cristiano T.
    Souza, Pamella R.
    Souza, Leandro E.
    Moreira, Edson D.
    da Silva, Maikon B.
    Irigoyen, Maria C.
    Krieger, Eduardo M.
    HYPERTENSION, 2011, 58 (05) : E170 - E170
  • [7] DYNAMIC PRESSURE METROLOGY
    BEAN, VE
    METROLOGIA, 1994, 30 (06) : 737 - 741
  • [9] Personnel training requirements for metrology
    Rosson, H
    METROLOGY - AT THE THRESHOLD OF THE CENTURY ARE WE READY?, 1999, : 171 - 180
  • [10] Personalizing Intraocular Pressure: Target Intraocular Pressure in the Setting of 24-Hour Intraocular Pressure Monitoring
    Sit, Arthur J.
    Pruet, Christopher M.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2016, 5 (01): : 17 - 22