Predictive power of PTV volume for choosing manual or automatic planning in lung stereotactic body radiotherapy

被引:0
|
作者
Duan, Yanhua [1 ,2 ]
Feng, Aihui [1 ,2 ]
Liu, Ning [3 ,4 ]
Shao, Yan [2 ]
Kong, Qing [1 ]
Zhou, Tao [3 ,4 ]
Xu, Zhiyong [2 ]
机构
[1] Fudan Univ, Inst Modern Phys, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Shanghai Chest Hosp, Dept Radiat Oncol, Shanghai, Peoples R China
[3] Univ Sci & Technol China, Affiliated Hosp USTC 1, Dept Radiotherapy, Div Life Sci & Med, Hefei, Anhui, Peoples R China
[4] Anhui Prov Canc Hosp, Dept Radiotherapy, Hefei, Anhui, Peoples R China
关键词
Lung cancer; SBRT; PTV volume; Automatic plan; Manual plan; Cut-off point; RADIATION-THERAPY; CANCER; SBRT;
D O I
10.1016/j.jrras.2024.100973
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: This study investigated the role of Planning Target Volume (PTV) in determining the suitability of manual and automatic Stereotactic Body Radiation Therapy (SBRT) planning for lung cancer patients. Methods: We retrospectively created manual and automatic lung SBRT plans for ninety-eight patients using the Pinnacle 16.2 Treatment Planning System (TPS). The superior plan, whether manual or automatic, was selected for each patient through a combined index. Receiver Operating Characteristic (ROC) analysis was used to assess the predictive potential of the PTV volume in determining the superior plan and to establish a cutoff value. Patients were then stratified into two groups based on this value, and dosimetric variances were evaluated. Results: The ROC analysis highlighted the PTV volume's proficiency in predicting the superior choice between manual and automatic lung SBRT plans (Area Under Curve (AUC): 0.918, p = 0.005). The delineated cutoff value was set at 22.675 cc. For PTV volumes below this threshold, automatic plans surpassed manual plans in the Conformity Index (CI), Gradient Index (GI), and lung doses. Conversely, for PTV volumes exceeding 22.675 cc, manual plans exhibited improved results in the Heterogeneity Index (HI), GI, and dosimetric metric of heart and lung. Conclusion: The PTV volume is a significant determinant in guiding the optimal selection between manual and automatic lung SBRT plans with the Pinnacle TPS. Automatic plans are recommended for patients with PTV volumes below 22.675 cc, and manual plans for those above this threshold.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Planning target volume (PTV) reduction for gated stereotactic body radiotherapy(SBRT) of lung tumors
    Kraus, K.
    Wilkens, J. J.
    Oechsner, M.
    Combs, S. E.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S893 - S893
  • [2] PTV vs ITV Based VMAT Plan on Stereotactic Body-Radiotherapy of Lung Tumors: Is PTV a Good Surrogate of Setup Uncertainties for Planning?
    Liang, X.
    Zheng, D.
    Mamalui-hunter, M.
    Flampouri, S.
    Hoppe, B.
    Mendenhall, N.
    Li, Z.
    MEDICAL PHYSICS, 2018, 45 (06) : E527 - E527
  • [3] Assessment of PTV Margin for Image Guided Stereotactic Body Radiotherapy for Lung Cancer
    Wong, T. P.
    Saini, J.
    Chen, F.
    Rao, M.
    Cao, D.
    Ye, J.
    Afghan, M.
    Wu, J.
    Shepard, D.
    Mehta, V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S788 - S788
  • [4] A method for optimizing planning target volume margins for patients receiving lung stereotactic body radiotherapy
    Wierzbicki, Marcin
    Mathew, Lindsay
    Swaminath, Anand
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (19):
  • [5] Volume Dose Prescription in Stereotactic Body Radiotherapy for Lung Cancer
    Terahara, A.
    Saotome, N.
    Miyamoto, K.
    Omori, M.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S207 - S207
  • [6] Stereotactic body radiotherapy (SBRT) for primary lung cancer at a dose of 50 Gy per 5 fractions to the periphery of the planning target volume (PTV) calculated by a superposition algorithm
    Takeda, A.
    Sanuki, N.
    Kunieda, E.
    Ohashi, T.
    Oku, Y.
    Takeda, T.
    Shigematsu, N.
    Kubo, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S624 - S625
  • [7] SGRT-based stereotactic body radiotherapy for lung cancer setup accuracy and PTV margins
    Guo, Hailiang
    Wu, Weiwei
    Zhang, Huaiwen
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5481 - S5483
  • [8] SGRT-based stereotactic body radiotherapy for lung cancer setup accuracy and margin of the PTV
    Guo, Hai-Liang
    Wu, Wei-Wei
    Huan, Yan
    Zhang, Huai-Wen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (03):
  • [9] Choosing the optimal gated window for defining target volume in lung stereotactic ablative radiotherapy
    Nardone, V.
    Sangiovanni, A.
    Scala, F.
    Mormile, M.
    D'Onofrio, I.
    Giugliano, F.
    Vitale, C.
    Muto, M.
    Reginelli, A.
    Cappabianca, S.
    Guida, C.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (02): : 429 - 435
  • [10] Respiratory Motion-Encompassing Planning Target Volume (ME-PTV) for Stereotactic Body Radiation Therapy (SBRT) of Lung Cancer
    Hossain, M.
    Shaikh, T. A.
    Jin, L.
    Turaka, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S897 - S897