Sustainable and fast synthesis of zinc-phthalocyanine for gamma radiation dosimeter application

被引:1
|
作者
Vasiljevic, Bojana R. [1 ]
Odobas, Daliborka [2 ]
Vujicic, Ivica [1 ]
Filimonovic, Milica Budimir [1 ]
Smits, Krisjanis [3 ]
Mijin, Dusan [4 ]
Marinkovic, Dragana [1 ]
机构
[1] Univ Belgrade, Vinca Inst Nucl Sci, Natl Inst Republ Serbia, POB 522, Belgrade 11001, Serbia
[2] Univ Belgrade, Fac Phys Chem, Studentski Trg 12-16, Belgrade 11000, Serbia
[3] Univ Latvia, Inst Solid State Phys, Lab Opt Mat, Kengaraga St 8, LV-1063 Riga, Latvia
[4] Univ Belgrade, Fac Technol & Met, Dept Organ Chem, Karnegijeva 4, Belgrade 11000, Serbia
关键词
Zinc phthalocyanine; Microwaves; Gamma irradiation; Dosimetry; PHOTODYNAMIC THERAPY; OPTICAL-PROPERTIES; THIN-FILMS; BAND-GAP; IRRADIATION; COMPOSITE; NANOPARTICLES; TECHNOLOGIES;
D O I
10.1016/j.radphyschem.2024.111816
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In the present research, the two different systems of dye based on zinc phthalocyanine were prepared by microwave-induced synthesis and conventional methods. They were evaluated as new effective chemical-based dosimeters for gamma irradiation. The sensitivity of the prepared dosimeters was examined by studying the comparative results between them through the changes in structural and optical properties upon exposure to different gamma irradiation doses. The color bleaching of the solutions was followed spectrophotometrically. Gradual changes from blue to light yellow color of zinc phthalocyanine solution, with the increase of the gamma radiation dose, were observed due to the decomposition of the dyes based on the zinc phthalocyanine. The synthesized zinc phthalocyanine chemical-based dosimeters for measurement of gamma irradiation up to 25kGy showed excellent stability after irradiation in terms of morphology and structure, which makes them a suitable novel material as composite-based dosimeters of gamma irradiation.
引用
收藏
页数:8
相关论文
共 42 条
  • [1] Electron beam modified zinc phthalocyanine thin films for radiation dosimeter application
    Chaudhary, Nishant
    Singh, Ajay
    Aswal, D. K.
    Debnath, A. K.
    Samanta, S.
    Koiry, S. P.
    Sharma, S.
    Shah, K.
    Acharya, S.
    Muthe, K. P.
    Gadkari, S. C.
    SYNTHETIC METALS, 2017, 231 : 143 - 152
  • [2] Microwave-induced synthesis of zinc-phthalocyanine with improved photosensitizing potential
    Vasiljevic, Bojana
    Milivojevic, Dusan
    Barudzija, Tanja
    Budimir, Milica
    Mijin, Dusan
    Marinovic-Cincovic, Milena
    Marinkovic, Dragana
    MATERIALS LETTERS, 2023, 350
  • [3] Synthesis and photovoltaic properties of two new unsymmetrical zinc-phthalocyanine dyes
    Huang, Hongyan
    Cao, Zhencai
    Li, Xiangling
    Zhang, Lingjun
    Liu, Xunshan
    Zhao, Huifang
    Tan, Songting
    SYNTHETIC METALS, 2012, 162 (24) : 2316 - 2321
  • [4] Synthesis, photophysical and photobiological study of synergic photosensitizer:: Zinc-phthalocyanine with Ca2+ chelating agent
    Lunardi, Claure N.
    Rotta, Jeane. C. G.
    Tedesco, Antonio C.
    CURRENT ORGANIC CHEMISTRY, 2007, 11 (07) : 647 - 654
  • [6] Application of the Sunna dosimeter film in gamma and electron beam radiation processing
    Kovacs, A
    Baranyai, M
    Wojnarovits, L
    McLaughlin, WL
    Miller, SD
    Miller, A
    Fuochi, PG
    Lavalle, M
    Slezsak, I
    RADIATION PHYSICS AND CHEMISTRY, 2000, 57 (3-6) : 691 - 695
  • [7] A versatile radiochromic dosimeter for low-medium gamma radiation and its application to food irradiation
    Lopes, Franceline Aparecida
    Ferreira, Giovana Ribeiro
    Franco, Marcella Rocha
    Schimitberger, Thiago
    de Faria, Luiz Oliveira
    Bianchi, Rodrigo Fernando
    JOURNAL OF APPLIED POLYMER SCIENCE, 2018, 135 (13)
  • [8] New unsymmetrical zinc-phthalocyanine conjugated with one azo-dye moiety:: Synthesis via opening the fused triazole ring and spectral properties
    Micó, XA
    Vagin, SI
    Subramanian, LR
    Ziegler, T
    Hanack, M
    EUROPEAN JOURNAL OF ORGANIC CHEMISTRY, 2005, 2005 (20) : 4328 - 4337
  • [9] EFFECT OF GAMMA-RADIATION ON THE SYNTHESIS OF METHANOL OVER ZINC OXIDE
    BARRY, TI
    ROBERTS, R
    NATURE, 1959, 184 (4692) : 1061 - 1062
  • [10] APPLICATION OF CAF2 - TM (TLD-300) DOSIMETER TO THE DISCRIMINATION BETWEEN ALPHA-RADIATION, BETA-RADIATION, AND GAMMA-RADIATION
    WANG, TK
    HSU, PC
    WENG, PS
    APPLIED RADIATION AND ISOTOPES, 1989, 40 (04) : 329 - 335