Development and Validation of an Automated, Real-Time Predictive Model for Postpartum Hemorrhage

被引:0
|
作者
Ende, Holly B. [1 ]
Domenico, Henry J.
Polic, Aleksandra
Wesoloski, Amber
Zuckerwise, Lisa C.
Mccoy, Allison B.
Woytash, Annastacia R.
Moore, Ryan P.
Byrne, Daniel W.
机构
[1] Vanderbilt Univ, Dept Anesthesiol, Med Ctr, Nashville, TN 37232 USA
来源
OBSTETRICS AND GYNECOLOGY | 2024年 / 144卷 / 01期
关键词
PLACENTA PREVIA; TRANEXAMIC ACID; SCORING MODEL; BLOOD-LOSS; DELIVERY; RISK; COMPLICATIONS; TRANSFUSION; PREGNANCIES; PREVENTION;
D O I
10.1097/AOG.0000000000005600
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: To develop and validate a predictive model for postpartum hemorrhage that can be deployed in clinical care using automated, real-time electronic health record (EHR) data and to compare performance of the model with a nationally published risk prediction tool. METHODS: A multivariable logistic regression model was developed from retrospective EHR data from 21,108 patients delivering at a quaternary medical center between January 1, 2018, and April 30, 2022. Deliveries were divided into derivation and validation sets based on an 80/20 split by date of delivery. Postpartum hemorrhage was defined as blood loss of 1,000 mL or more in addition to postpartum transfusion of 1 or more units of packed red blood cells. Model performance was evaluated by the area under the receiver operating characteristic curve (AUC) and was compared with a postpartum hemorrhage risk assessment tool published by the CMQCC (California Maternal Quality Care Collaborative). The model was then programmed into the EHR and again validated with prospectively collected data from 928 patients between November 7, 2023, and January 31, 2024. RESULTS: Postpartum hemorrhage occurred in 235 of 16,862 patients (1.4%) in the derivation cohort. The predictive model included 21 risk factors and demonstrated an AUC of 0.81 (95% CI, 0.79-0.84) and calibration slope of 1.0 (Brier score 0.013). During external temporal validation, the model maintained discrimination (AUC 0.80, 95% CI, 0.72-0.84) and calibration (calibration slope 0.95, Brier score 0.014). This was superior to the CMQCC tool (AUC 0.69 [95% CI, 0.67-0.70], P<.001). The model maintained performance in prospective, automated data collected with the predictive model in real time (AUC 0.82 [95% CI, 0.73-0.91]). CONCLUSION: We created and temporally validated a postpartum hemorrhage prediction model, demonstrated its superior performance over a commonly used risk prediction tool, successfully coded the model into the EHR, and prospectively validated the model using risk factor data collected in real time. Future work should evaluate external generalizability and effects on patient outcomes; to facilitate this work, we have included the model coefficients and examples of EHR integration in the article.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 50 条
  • [1] Development and validation of a predictive model for postpartum endometritis
    Wang, Xiujuan
    Shao, Hui
    Liu, Xueli
    Feng, Lili
    PLOS ONE, 2024, 19 (07):
  • [2] Development and validation of a predictive model for severe postpartum hemorrhage in women undergoing vaginal delivery: A retrospective cohort study
    Liu, Chenning
    Xu, Yunzhe
    Li, Jinsheng
    Guan, Zhihong
    Liu, Chenan
    He, Fang
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2022, 157 (02) : 353 - 358
  • [3] DEVELOPMENT AND VALIDATION OF AN AUTOMATED COMPUTER VISION ALGORITHM FOR REAL-TIME EMBRYO VIABILITY PREDICTION
    Loewke, K.
    Moussavi, F.
    Maddah, M.
    Ivani, K.
    Behr, B.
    Suraj, V.
    FERTILITY AND STERILITY, 2012, 98 (03) : S288 - S289
  • [4] Development and Validation of a Comprehensive Synchronous Machine Model for a Real-Time Environment
    Dehkordi, A. B.
    Neti, Prabhakar
    Gole, A. M.
    Maguire, T. L.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (01) : 34 - 48
  • [5] On real-time robust model predictive control
    Zeilinger, Melanie N.
    Raimondo, Davide M.
    Domahidi, Alexander
    Morari, Manfred
    Jones, Colin N.
    AUTOMATICA, 2014, 50 (03) : 683 - 694
  • [6] Real-time implementation of model predictive control
    Bleris, LG
    Kothare, MV
    ACC: PROCEEDINGS OF THE 2005 AMERICAN CONTROL CONFERENCE, VOLS 1-7, 2005, : 4166 - 4171
  • [7] Development and validation of a predictive model for the prognosis in aneurysmal subarachnoid hemorrhage
    Lai, Xiang
    Zhang, Wenbo
    Ye, Min
    Liu, Xiaoping
    Luo, Xingda
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2020, 34 (12)
  • [8] Development and validation of a time-series model for real-time thermal load estimation
    Ogunsola, Oluwaseyi T.
    Song, Li
    Wang, Gang
    ENERGY AND BUILDINGS, 2014, 76 : 440 - 449
  • [9] Validation of a quantitative system for real-time measurement of postpartum blood loss
    Kahr, Maike Katja
    Brun, Romana
    Zimmermann, Roland
    Franke, Denise
    Haslinger, Christian
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2018, 298 (06) : 1071 - 1077
  • [10] Validation of a quantitative system for real-time measurement of postpartum blood loss
    Maike Katja Kahr
    Romana Brun
    Roland Zimmermann
    Denise Franke
    Christian Haslinger
    Archives of Gynecology and Obstetrics, 2018, 298 : 1071 - 1077