A Comparative Evaluation of Surface Hardness and Nanomechanical Properties of Nickel-Titanium Orthodontic Wires: An In Vitro Study

被引:0
|
作者
Santhakumari, Prasanth Prathapan [1 ]
Raja, Vighnesh Varma [2 ]
Kalarickal, Biju [3 ]
Parambil, Mohamed Haris Thavalam [4 ]
Sebastian, Joseph [3 ]
Cheeramelil, Jacob [3 ]
机构
[1] Indira Gandhi Inst Dent Sci, Dept Orthodont & Dentofacial Orthoped, Kothamangalam, India
[2] Annoor Dent Coll & Hosp, Dept Orthodont & Dentofacial Orthoped, Muvattupuzha, India
[3] Mar Baselios Dent Coll, Dept Orthodont & Dentofacial Orthoped, Kothamangalam, India
[4] Educare Inst Dent Sci, Dept Orthodont & Dentofacial Orthoped, Malappuram, India
关键词
surface hardness; niti wires; nanoindentation; nanohardness; coated archwires; ROUGHNESS; ARCHWIRES;
D O I
10.7759/cureus.64284
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The study aimed to evaluate the influence of various surface coatings (epoxy, Teflon, and rhodium) on the surface roughness (SR) and nanomechanical characteristics of nickel-titanium (NiTi) archwires. The study compared these coated archwires to uncoated ones from a single manufacturer, which served as a control. Materials and methods: There were 15 rectangular samples of four distinct archwires measuring 0.17 x 0.25. These were ultrasonically treated with an alkaline solution at 60 degrees C for 15 minutes before being rinsed with distilled water to remove precipitates. With an orthodontic soft wire cutter, the straight buccal sections of coated and uncoated archwires were cut into 20 mm lengths. A three-dimensional optical noncontact surface profilometer evaluated the surface. Profilometers use contact scanning white light interferometry. Using the Vision64 software (Bruker Corporation, San Jose, CA), the profilometer's nanolens atomic force microscopy module has a completely automated turret with programmed X, Y, and Z motions. Images were taken in five random locations. Five average measurements matched specimen SR. A nanoindenter with a Berkovich diamond indenter measured nanohardness (NH) and elastic modulus (EM). The experimental results were analyzed using the Statistical Package for the Social Sciences software version 26.0 (SPSS Inc., Chicago, IL). To examine mean differences at 5% significance, analysis of variance and Tukey's post hoc test were applied for SR, NH, and EM. Results: Wires coated with epoxy had the highest SR (1.499 +/- 0.082), followed by Teflon (0.811 +/- 0.023) and rhodium (0.308 +/- 0.024). The SR of the control group was 0.289 +/- 0.027. Significant differences in SR were found (p < 0.0001). Except for the comparison between rhodium and the control group (p = 0.684), all intergroup comparisons of SR showed significant differences (p < 0.0001). The rhodium-coated wires exhibited the highest NH (0.185 +/- 0.014), and the epoxy group had the lowest (0.147 +/- 0.017). Variations in NH were significant between the study groups (p < 0.0001). The epoxy, Teflon, and rhodium groups showed significant differences against the control group (p < 0.0001) in intergroup comparisons for NH. The Teflon group had the highest EM (5.367 +/- 0.379), and the epoxy group had the lowest (5.012 +/- 0.498). The EM of the control group was 56.946 +/- 0.737. Results indicate considerable EM changes between the groups (p < 0.05). Comparisons between experimental and control groups showed significant differences (p < 0.0001). Conclusion: The study's findings indicate that the SR of rhodium-coated archwires is substantially comparable to that of uncoated archwires. However, Teflon-, rhodium-, and epoxy-coated archwires had significantly different NH and EM compared to uncoated ones. Further, uncoated archwires have higher NH and EM.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Evaluation of nanomechanical properties, surface roughness, and color stability of esthetic nickel-titanium orthodontic archwires
    Alsanea, Jamal A.
    Al Shehri, Hassan
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2019, 9 (01): : 33 - 39
  • [2] Comparison of the mechanical properties of orthodontic nickel-titanium wires
    Kayser, D
    Bourauel, C
    Braumann, B
    Jäger, A
    BIOMEDIZINISCHE TECHNIK, 2002, 47 (12): : 334 - 342
  • [3] Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires
    Katic, Visnja
    Curkovic, Helena Otmacic
    Semenski, Damir
    Barsic, Gorana
    Marusic, Katarina
    Spalj, Stjepan
    ANGLE ORTHODONTIST, 2014, 84 (06) : 1041 - 1048
  • [4] Load Deflection Characteristics of Orthodontic Gummetal® Wires in Comparison with Nickel-Titanium Wires: An In Vitro Study
    Sabbagh, Hisham
    Janjic Rankovic, Mila
    Martin, Daniel
    Mertmann, Matthias
    Hoetzel, Linus
    Wichelhaus, Andrea
    Sfondrini, Maria Francesca
    MATERIALS, 2024, 17 (02)
  • [5] Surface composition and microtopography of nickel-titanium orthodontic wires.
    Bradley, TG
    Mitchell, JC
    Brantley, WA
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 346 - 346
  • [6] BENDING PROPERTIES OF SUPERELASTIC AND NONSUPERELASTIC NICKEL-TITANIUM ORTHODONTIC WIRES
    KHIER, SE
    BRANTLEY, WA
    FOURNELLE, RA
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1991, 99 (04) : 310 - 318
  • [7] Effect of coating on properties of esthetic orthodontic nickel-titanium wires
    Iijima, Masahiro
    Muguruma, Takeshi
    Brantley, William A.
    Choe, Han-Cheol
    Nakagaki, Susumu
    Alapati, Satish B.
    Mizoguchi, Itaru
    ANGLE ORTHODONTIST, 2012, 82 (02) : 319 - 325
  • [8] Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
    Kim, H
    Johnson, JW
    ANGLE ORTHODONTIST, 1999, 69 (01) : 39 - 44
  • [9] DIFFERENTIAL SCANNING CALORIMETRIC STUDY OF NICKEL-TITANIUM ORTHODONTIC WIRES
    BRADLEY, TG
    BRANTLEY, WA
    CULBERTSON, BM
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 414 - 414
  • [10] Nanomechanical evaluation of nickel-titanium surface properties after alkali and electrochemical treatments
    Chrzanowski, Wojciech
    Abou Neel, Ensanya Ali
    Armitage, David Andrew
    Lee, Kevin
    Walke, Witold
    Knowles, Jonathan Campbell
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2008, 5 (26) : 1009 - 1022