Four-Bolt Unstiffened End-Plate Moment Connections with 36-in.-Deep Beams for Intermediate Moment Frames

被引:0
|
作者
Mercado-Celin, Maria A. [1 ]
Eatherton, Matthew R. [1 ]
Murray, Thomas M. [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Blacksburg, VA 24061 USA
来源
ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION | 2024年 / 61卷 / 01期
关键词
end-plate moment connection; intermediate moment frame; lateral-torsional buckling; beam net section fracture; moderately; ductile section;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Previous testing has shown that four-bolt extended, unstiffened end-plate moment connections can be used with beams up to 24 in. deep and develop sufficiently ductile performance to satisfy seismic qualification. It is desirable to extend this depth limit to allow deeper beams for intermediate moment frames. Three moment connection specimens using built-up 36-in.-deep beams with a four-bolt extended, unstiffened end- plate moment connection were tested to determine if they satisfy the intermediate moment frame qualification criteria given in AISC 341-16 (2016a). The web of the specimens satisfied the moderately ductile section criteria for web slenderness, which is required for intermediate moment frames, but not highly ductile section criteria required for special moment frames. All three specimens passed qualification criteria for intermediate moment frames (IMFs) as given in AISC 341-16 by retaining at least 80% of the nominal plastic moment strength through 2% story drift. The observed failure modes included lateral torsional buckling of the specimen, flange local buckling, net section fracture of the beam flange, and failure of the beam flange-to-beam web fillet weld. The results of these tests support current moderately ductile limits associated with lateral bracing and cross-section slenderness, given that the associated specimens reached IMF qualification criteria but not special moment frame (SMF) criteria. It was concluded that four-bolt extended, unstiffened end-plate moment connections satisfy intermediate moment frame requirements with a beam depth of 36 in. and that a modification is needed for beam web to flange welds in built- up sections near the moment connection.
引用
收藏
页码:47 / 58
页数:12
相关论文
共 50 条
  • [1] Four-Bolt Unstiffened End-Plate Moment Connections with 36-in.-Deep Beams for Intermediate Moment Frames
    Mercado-Celin M.A.
    Eatherton M.R.
    Murray T.M.
    Engineering Journal, 2024, 61 (01): : 47 - 58
  • [2] FE modeling of four-bolt, tubular moment end-plate connections
    Wheeler, AT
    Clarke, MJ
    Hancock, GJ
    JOURNAL OF STRUCTURAL ENGINEERING, 2000, 126 (07) : 816 - 822
  • [3] An Unstiffened Eight-Bolt Extended End-Plate Moment Connection for Special and Intermediate Moment Frames
    Morrison, Machel L.
    Schweizer, Doug Q.
    Quayyum, Shahriar
    Hassan, Tasnim
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (07)
  • [4] Experiments and Analysis of Unstiffened Eight-Bolt End-Plate Moment Connections for Seismic Applications
    Morrison, Machel
    Suarez, Sergio
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (04)
  • [5] The plastic and the ultimate resistance of four-bolt extended end-plate connections
    Ozkilic, Yasin Onuralp
    Topkaya, Cem
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 181
  • [6] Low cycle fatigue life prediction using a four-bolt extended unstiffened end plate moment connection
    Lim, Chemin
    Choi, Wonchang
    Sumner, Emmett A.
    ENGINEERING STRUCTURES, 2012, 41 : 373 - 384
  • [7] Seismic analysis of eight-bolt unstiffened end plate moment connections
    Quayyum, Shahriar
    Morrison, Machel L.
    Hassan, Tasnim
    Kohany, Timothy R.
    STRUCTURAL ENGINEERING AND MECHANICS, 2025, 93 (02) : 95 - 113
  • [8] Adopting flexibility of the end-plate connections in steel moment frames
    Ghassemieh, M.
    Baei, M.
    Kari, A.
    Goudarzi, A.
    Laefer, D. F.
    STEEL AND COMPOSITE STRUCTURES, 2015, 18 (05): : 1215 - 1237
  • [9] Structural Reliability Assessment of Steel Four-Bolt Unstiffened Extended End-Plate Connections Using Monte Carlo Simulation and Artificial Neural Networks
    Hamidreza Abbasianjahromi
    Somayeh Shojaeikhah
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2021, 45 : 111 - 123
  • [10] Structural Reliability Assessment of Steel Four-Bolt Unstiffened Extended End-Plate Connections Using Monte Carlo Simulation and Artificial Neural Networks
    Abbasianjahromi, Hamidreza
    Shojaeikhah, Somayeh
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2021, 45 (01) : 111 - 123