Degradation of Seismic Performance of Thin Steel Plate Shear Walls in Earthquakes

被引:0
|
作者
Du, Yipeng [1 ]
Zhang, Min [1 ]
Cao, Yifang [2 ]
Xue, Lei [3 ]
机构
[1] Southwest Petr Univ, Sch Civil Engn & Geomat, Chengdu 610500, Peoples R China
[2] Univ Sydney, Sch Civil Engn, Sydney, NSW 2050, Australia
[3] China Railway First Survey & Design Inst Grp Co Lt, Xian 710043, Peoples R China
基金
中国国家自然科学基金;
关键词
steel plate wall; quasistatic test; earthquake damage; performance degradation; failure mode;
D O I
10.3390/buildings14040888
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel plate shear walls (SPSWs) are widely used in earthquake-prone areas, and they usually undergo multiple earthquakes throughout their service lives. The performances of SPSWs under a single shot of an earthquake have been widely studied, although the secondary seismic performance of earthquake-damaged structures remains unclear. Damage to an SPSW structure during an earthquake is difficult to evaluate. In this study, the degradation of the seismic performance of SPSWs during earthquakes was investigated. A test specimen was subjected to a two-stage quasistatic load. The plastic development and failure modes of SPSW specimens were investigated. The degradation of bearing capacity, stiffness, and energy dissipation performance was analyzed. On the basis of the experimental investigation, finite-element models introducing the ductile damage criterion and the cyclic constitutive model of steel were established. The degradation of the seismic performance of SPSWs under secondary earthquakes was studied. The results indicate that the stiffness of the SPSWs degrades more significantly than the bearing capacity. The larger the height-to-thickness ratio of the embedded plate, the more obvious the decrease in the bearing capacity, and the smaller the decrease in stiffness. With the increase in the maximum lateral displacement reached by the structure in an earthquake, and as the pinch phenomenon of the hysteresis curve of the SPSW becomes more serious, the energy dissipation capacity shows a uniform downward trend.
引用
收藏
页数:20
相关论文
共 50 条
  • [2] SEISMIC RESISTANCE OF STEEL PLATE SHEAR WALLS
    ROBERTS, TM
    ENGINEERING STRUCTURES, 1995, 17 (05) : 344 - 351
  • [3] Seismic Performance of Flat Steel Plate Shear Walls with Atmospheric Corrosion
    Ma, Xiaoming
    Hu, Yi
    Cheng, Xinyuan
    Jiang, Liqiang
    Li, Yun
    Zheng, Hong
    BUILDINGS, 2022, 12 (11)
  • [4] Seismic performance of corrugated steel plate concrete composite shear walls
    Wang, Wei
    Ren, Yingzi
    Han, Bin
    Ren, Tan
    Liu, Gewei
    Liang, Yujian
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (01):
  • [5] SHEAR ANALYSIS OF THIN STEEL PLATE SHEAR WALLS
    Esfandiar, R.
    Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 528 - 533
  • [6] Seismic performance of composite plate shear walls
    Dey, Sandip
    Bhowmick, Anjan K.
    STRUCTURES, 2016, 6 : 59 - 72
  • [7] Seismic performance of slit steel plate shear walls strengthened by FRP laminate
    Du, Yipeng
    Liao, Xin
    Shao, Yongbo
    Zhang, Min
    Wu, Changgen
    Cao, Yifang
    JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [8] Seismic performance assessment of steel plate shear walls equipped with passive dampers
    Ahmed, Mohammed M.
    Mamazizi, Arman
    Soltanabadi, Reza
    Jalali, Himan Hojat
    STRUCTURES, 2023, 55 : 1204 - 1218
  • [9] Nonlinear seismic performance of code designed perforated steel plate shear walls
    Barua, Kallol
    Bhowmick, Anjan K.
    STEEL AND COMPOSITE STRUCTURES, 2019, 31 (01): : 85 - 98
  • [10] Improving seismic performance of composite steel plate shear walls containing openings
    Meghdadaian, Mohammad
    Ghalehnovi, Mansour
    JOURNAL OF BUILDING ENGINEERING, 2019, 21 : 336 - 342