Comparison of Virtual Non-Contrast and True Non-Contrast CT Images Obtained by Dual-Layer Spectral CT in COPD Patients

被引:0
|
作者
Steinhardt, Manuel [1 ,2 ]
Marka, Alexander W. [1 ,2 ]
Ziegelmayer, Sebastian [1 ,2 ]
Makowski, Marcus [1 ,2 ]
Braren, Rickmer [1 ,2 ]
Graf, Markus [1 ,2 ]
Gawlitza, Joshua [1 ,2 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, D-81675 Munich, Germany
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 04期
关键词
COPD; computed tomography imaging; virtual non-contrast images; true non-contrast images; dual-layer spectral CT; emphysema quantification; lung imaging; radiation exposure; image comparison analysis;
D O I
10.3390/bioengineering11040301
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Chronic obstructive pulmonary disease (COPD) is one of the leading causes of death. Recent studies have underlined the importance of non-contrast-enhanced chest CT scans not only for emphysema progression quantification, but for correlation with clinical outcomes as well. As about 40 percent of the 300 million CT scans per year are contrast-enhanced, no proper emphysema quantification is available in a one-stop-shop approach for patients with known or newly diagnosed COPD. Since the introduction of spectral imaging (e.g., dual-energy CT scanners), it has been possible to create virtual non-contrast-enhanced images (VNC) from contrast-enhanced images, making it theoretically possible to offer proper COPD imaging despite contrast enhancing. This study is aimed towards investigating whether these VNC images are comparable to true non-contrast-enhanced images (TNC), thereby reducing the radiation exposure of patients and usage of resources in hospitals. In total, 100 COPD patients with two scans, one with (VNC) and one without contrast media (TNC), within 8 weeks or less obtained by a spectral CT using dual-layer technology, were included in this retrospective study. TNC and VNC were compared according to their voxel-density histograms. While the comparison showed significant differences in the low attenuated volumes (LAVs) of TNC and VNC regarding the emphysema threshold of -950 Houndsfield Units (HU), the 15th and 10th percentiles of the LAVs used as a proxy for pre-emphysema were comparable. Upon further investigation, the threshold-based LAVs (-950 HU) of TNC and VNC were comparable in patients with a water equivalent diameter (DW) below 270 mm. The study concludes that VNC imaging may be a viable option for assessing emphysema progression in COPD patients, particularly those with a normal body mass index (BMI). Further, pre-emphysema was generally comparable between TNC and VNC. This approach could potentially reduce radiation exposure and hospital resources by making additional TNC scans obsolete.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images
    Sauter, Andreas P.
    Muenzel, Daniela
    Dangelmaier, Julia
    Braren, Rickmer
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Noel, Peter B.
    Fingerle, Alexander A.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 104 : 108 - 114
  • [2] Association between true non-contrast and virtual non-contrast vertebral bone CT attenuation values determined using dual-layer spectral detector CT
    Ding, Yuqin
    Richter, Andreas
    Stiller, Wolfram
    Kauczor, Hans-Ulrich
    Weber, Tim Frederik
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2019, 121
  • [3] Comparison of virtual and true non-contrast images from dual-layer spectral detector computed tomography (CT) in patients with colorectal cancer
    Wen, Deying
    Pu, Qian
    Peng, Pengfei
    Yue, Xun
    Ming, Yue
    Yang, Huiyi
    Yang, Jianyang
    Zhang, Xiaodi
    Liu, Haiwei
    Yang, Lie
    Sun, Jiayu
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (09)
  • [4] Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
    Felix G. Gassert
    Claudio E. Schacky
    Christina Müller-Leisse
    Florian T. Gassert
    Gregor Pahn
    Karl-Ludwig Laugwitz
    Marcus R. Makowski
    Jonathan Nadjiri
    [J]. European Radiology, 2021, 31 : 6193 - 6199
  • [5] Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images
    Lee, Min Hee
    Park, Hee Jin
    Kim, Ji Na
    Kim, Myung Sub
    Hong, Seok Woo
    Park, Jai Hyung
    Kang, Chang Ho
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1138):
  • [6] Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
    Gassert, Felix G.
    Schacky, Claudio E.
    Mueller-Leisse, Christina
    Gassert, Florian T.
    Pahn, Gregor
    Laugwitz, Karl-Ludwig
    Makowski, Marcus R.
    Nadjiri, Jonathan
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (08) : 6193 - 6199
  • [7] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Hongwei Liang
    Silin Du
    Gaowu Yan
    Yang Zhou
    Tianyu Yang
    Zhiwei Zhang
    Chenyi Luo
    Hongfan Liao
    Yongmei Li
    [J]. Abdominal Radiology, 2023, 48 : 2596 - 2603
  • [8] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Liang, Hongwei
    Du, Silin
    Yan, Gaowu
    Zhou, Yang
    Yang, Tianyu
    Zhang, Zhiwei
    Luo, Chenyi
    Liao, Hongfan
    Li, Yongmei
    [J]. ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2596 - 2603
  • [9] Dual-Energy CT in the Assessment of Mediastinal Lymph Nodes: Comparative Study of Virtual Non-Contrast and True Non-Contrast Images
    Yoo, Seon Young
    Kim, Yookyung
    Cho, Hyun Hae
    Choi, Mi Joo
    Shim, Sung Shine
    Lee, Jeong Kyong
    Baek, Seung Yon
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (03) : 532 - 539
  • [10] Comparative study of true and virtual non-contrast imaging generated from dual-layer spectral CT in patients with upper aerodigestive tract cancer
    Mingkwansook, Varalee
    Puwametwongsa, Krittiya
    Watcharakorn, Arvemas
    Dechasasawat, Thanapat
    [J]. POLISH JOURNAL OF RADIOLOGY, 2022, 87 : E678 - E687