Transradial carotid artery stenting using double layer micromesh stent and novel post-dilation balloon with integrated embolic protection

被引:2
|
作者
Petkoska, Danica [1 ]
Zafirovska, Biljana [1 ]
Vasilev, Ivan [1 ]
Saylors, Elizabeth [2 ]
Sachar, Ravish [3 ]
Kedev, Sasko [1 ,4 ]
机构
[1] Univ Ss Cyril & Methodas, Univ Clin Cardiol, Med Fac, Skopje, North Macedonia
[2] Contego Med LLC, Raleigh, NC USA
[3] Univ N Carolina, North Carolina Heart & Vasc, UNC REX Healthcare, Raleigh, NC USA
[4] Univ St Cyril & Methodius, Univ Clin Cardiol, Fac Med, Intervent Cardiol Dept, Mother Teresa 17, Skopje 1000, North Macedonia
关键词
Cerebral embolic protection; Paladin device; Transradial access; Carotid stenosis; Carotid stenting; Double-layer micromesh stent; CEREBRAL PROTECTION; HIGH-RISK; REVASCULARIZATION ENDARTERECTOMY; CLINICAL-EXPERIENCE; PLAQUE PROTRUSION; PREVENTION; EMBOLIZATION; ANGIOPLASTY; DISTAL; TRIAL;
D O I
10.1016/j.carrev.2024.01.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The highest rate of embolization during carotid artery stenting occurs during post-dilation. We evaluated the ability of the Paladin system (Contego Medical, Raleigh, NC), a novel PTA balloon with an integrated 40-mu m pore filter, to collect microemboli that may pass into the cerebral circulation when used during post-dilation. Methods: 25 symptomatic patients underwent transradial CAS using the Paladin system in conjunction with the Roadsaver (Terumo Corporation, Tokyo, Japan) micromesh stent. No additional embolic protection was used. The Paladin filters were collected following the procedure and preserved in formalin for histological analysis. The contents were evaluated for particle count and size. Subjects were followed for 30 days and evaluated for major cardiac adverse events (death, stroke and MI). Secondary endpoints included procedure success, device success, access site complications according to EASY score classification, major vascular or ischemic complications at follow up and in-stent restenosis rate evaluated with duplex ultrasound. Results: Mean age of patients was 68,5 years. Type 2 aortic arch was present in 77 % of patients and type 1 and type 3 in 12 % and 11 % of patients respectively. Procedural and device success was obtained in all cases without complications. The 30-day MAE rate was 0 %. Twenty-three filters underwent histological analysis. Microscopic debris was present in 100 % of filters, and 75 % of particles were less than 100 mu m in size. The mean number of particles per filter was 3352 +/- 1567 (IQR 4300-2343), and the mean number of particles between 40-100 mu m per filter was 2499 +/- 1240 (IQR 3227-1575). Conclusion: CAS through radial approach can be safely and effectively performed using the IEP technology Paladin device and double-layer micromesh Roadsaver stent. This strategy can simplify the procedure and decrease periprocedural complications and procedural time.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 50 条
  • [1] Invited Commentary for "Transradial carotid artery stenting using double layer micromesh stent and novel post-dilation balloon with integrated embolic protection "
    Pancholy, Samir B.
    Shah, Sanjay
    Patel, Tejas M.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 63 : 52 - 53
  • [2] Double Filtration During Carotid Artery Stenting Using a Novel Post-Dilation Balloon With Integrated Embolic Protection
    Langhoff, Ralf
    Schofer, Joachim
    Scheinert, Dierk
    Schmidt, Andrej
    Sedgewick, Gerald
    Saylors, Elizabeth
    Sachar, Ravish
    Sievert, Horst
    Zeller, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) : 395 - 403
  • [3] PERFORMANCE 1 study: Novel carotid stent system with integrated post-dilation balloon and embolic protection device
    Langhoff, Ralf
    Petrov, Ivo
    Kedev, Sasko
    Milosevic, Zoran
    Schmidt, Andrej
    Scheinert, Dierk
    Schofer, Joachim
    Sievert, Horst
    Sedgewick, Gerald
    Saylors, Elizabeth
    Sachar, Ravish
    Cremonesi, Alberto
    Micari, Antonio
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 100 (06) : 1090 - 1099
  • [4] Carotid Artery Stenting without Post-dilation
    Spacek, Miloslav
    Zimolova, Petra
    Veselka, Josef
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (07): : 91S - 91S
  • [5] Carotid Artery Stenting Without Post-Dilation
    Spacek, Miloslav
    Zimolova, Petra
    Veselka, Josef
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2012, 25 (02) : 190 - 196
  • [6] Transradial Carotid Artery Stenting With Proximal Embolic Protection
    Trani, Carlo
    Burzotta, Francesco
    Coroleu, Santiago Federico
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (02) : 267 - 272
  • [7] Safety of Slender 5Fr Transradial Approach for Carotid Artery Stenting With a Novel Nitinol Double-Layer Micromesh Stent
    Kedev, Sasko
    Petkoska, Danica
    Zafirovska, Biljana
    Vasilev, Ivan
    Bertrand, Olivier F.
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 116 (06): : 977 - 981
  • [8] Successful carotid artery stenting with a double-layer micromesh stent for spontaneous extracranial internal carotid artery dissection: a case report
    Okumura, Taro
    Hattori, Kenichi
    Hatano, Hisashi
    Fujitani, Shigeru
    Wada, Kentaro
    Sato, Yoshiki
    Wakabayashi, Masahiro
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2022, 84 (02): : 462 - 469
  • [9] Double embolic protection during carotid artery stenting with persistent hypoglossal artery
    Silva, Christine F.
    Hou, Samuel Y.
    Kuehn, Anna L.
    Whitten, Richard H.
    Wakhloo, Ajay K.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (03) : e23
  • [10] Carotid Artery Stenting with Double Cerebral Embolic Protection in Symptomatic Patients
    Varbella, Ferdinando
    Tomassini, Francesco
    Gagnor, Andrea
    Gambino, Alfonso
    Pron, Paolo Giay
    Hartwig, Massimo
    Reggiani, Monica
    Amaru, Salvatore
    di Cortemiglia, Emilio Luda
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B163 - B163