Design and adaptability analysis of filling rate of a self-insulation wall considering thermal performance, benefit-cost, and cold-winter and hot-summer climate

被引:0
|
作者
Hu, Wentao [1 ]
Nickolaevich, Alekhin Vladimir [1 ]
Huang, Yue [2 ]
Xiao, Shuoting [1 ]
机构
[1] Ural Fed Univ, Inst Civil Engn & Architecture, 19 Mira st, Ekaterinburg 620002, Russia
[2] Ural Fed Univ, Ural Inst Humanities, 51 Lenina st, Ekaterinburg 620002, Russia
关键词
Self-insulated wall; Insulation materials; Thermal performance; Comparative test method; Benefit-cost analysis method; OPTIMIZATION;
D O I
10.1016/j.cscm.2024.e03256
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The filling rate of different insulation materials significantly affects three influencing factors of self-insulating walls: insulation performance, benefit-cost, and climate adaptability. However, considering only one or two influencing factors of a self-insulating wall cannot satisfy the comprehensive needs of building users. Therefore, this experiment comprehensively considered three influencing factors to design five types of self-insulating wall models with different filling rates (0 %, 25 %, 50 %, 75 %, and 100 %) to obtain the best filling rate scheme for insulation materials. EnergyPlus software was used to simulate the operating state of the self-insulating walls. A comparative analysis of the thermal performance and economic benefit indices indicated that compared to Type (A-1), the average inner surface temperatures of Types (B-1), (C-1), (D-1), and (E-1) increased by 1.49 %, 2.72 %, 3.56 %, and 4.47 %, respectively, indicating that an increase in the filling rate of the insulation materials improved the insulation performance of the self-insulation wall. With the same increase in the filling rate of 25 %, the energy consumption of type (B-1) decreased by 8.66 KWh/m2, and the decrease range was the largest (i.e., by 7.65 %), indicating that Type (B-1) offered the best value for money in terms of energy savings and material costs. The EPS filling rate of Type (B-1) is 25 % and the thickness is 30 mm, which best meets the requirements of the economic thickness value of thermal insulation material (dEPS >= 27 mm), which also indicating that Type (B-1) can satisfy the comprehensive requirements of thermal insulation performance and cost savings in hot-summer and cold-winter climates, so Type (B-1) is the best filling scheme.
引用
收藏
页数:12
相关论文
共 24 条
  • [1] The Effects of Courtyards on the Thermal Performance of a Vernacular House in a Hot-Summer and Cold-Winter Climate
    Hao, Shimeng
    Yu, Changming
    Xu, Yuejia
    Song, Yehao
    [J]. ENERGIES, 2019, 12 (06):
  • [2] Thermal performance of phase-change wall of a hotel building under hot-summer and cold-winter climate
    Tong, Jiaping
    Wang, Yalin
    Qiu, Zhongzhu
    Zhang, Jingkui
    Li, Shengnan
    Li, Chunying
    Jiao, Zizhuang
    Chen, Ling
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2024,
  • [3] ANALYSIS OF THE ECONOMICAL THICKNESS OF THERMAL INSULATION LAYER OF THE BUILDING ENVELOPE IN THE HOT-SUMMER AND COLD-WINTER ZONE
    Guo, Yonghui
    Zhang, Guoqiang
    Zhou, Jin
    Xie, Mingjing
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1455 - 1463
  • [4] Quantitative Study of Using Piloti for Passive Climate Adaptability in a Hot-Summer and Cold-Winter City in China
    Zhou, Zeng
    Deng, Qinli
    Yang, Guang
    Lin, Yaolin
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (10)
  • [5] A FIELD STUDY OF THERMAL COMFORT IN RESIDENTIAL BUILDINGS IN WINTER IN THE HOT-SUMMER AND COLD-WINTER CLIMATE REGION
    Li, Junge
    Liu, Jiaping
    Yang, Liu
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1152 - 1159
  • [6] Thermal performance of a novel solar thermal facade system in a hot-summer and cold-winter zone
    A, Yongga
    Li, Nianping
    Long, Jibo
    He, Yingdong
    [J]. SOLAR ENERGY, 2020, 204 (204) : 106 - 114
  • [7] Performance-Based Evaluation of Courtyard Design in China's Cold-Winter Hot-Summer Climate Regions
    Xu, Xiaodong
    Luo, Fenlan
    Wang, Wei
    Hong, Tianzhen
    Fu, Xiuzhang
    [J]. SUSTAINABILITY, 2018, 10 (11):
  • [8] The effects of urban microclimate on outdoor thermal sensation and neutral temperature in hot-summer and cold-winter climate
    Liu, Weiwei
    Zhang, Yingxia
    Deng, Qihong
    [J]. ENERGY AND BUILDINGS, 2016, 128 : 190 - 197
  • [9] Research on Climate Adaptability of Energy Conservation Building with Renewable Energy Sources in Hot-summer and Cold-winter Zone of China
    Hui Zhang
    Zhuang Yu
    [J]. RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6, 2014, 448-453 : 1289 - 1296
  • [10] Daylighting and energy performance of window with transparent insulation slats combined with building shading in the hot-summer and cold-winter zone
    Li, Qingsong
    Zhang, Ling
    Wang, Xuchao
    Su, Xiaosong
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2024, 114