Association of Peri-Implant Mucosa Dimensions With Emergence Profile Angles of the Implant Prosthesis

被引:1
|
作者
Rungtanakiat, Piboon [1 ]
Thitaphanich, Natchaya [1 ]
Janda, Martin [2 ]
Strauss, Franz Josef [3 ,4 ]
Arksornnukit, Mansuang [1 ]
Mattheos, Nikos [5 ,6 ]
机构
[1] Chulalongkorn Univ, Fac Dent, Dept Prosthodont, Bangkok, Thailand
[2] Malmoe Univ, Fac Odontol, Dept Orthodont, Malmo, Sweden
[3] Univ Zurich, Ctr Dent Med, Clin Reconstruct Dent, Zurich, Switzerland
[4] Univ Finis Terrae, Fac Dent, Santiago, Chile
[5] Chulalongkorn Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Bangkok, Thailand
[6] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
来源
关键词
dental implants; emergence angle; implant supracrestal complex; peri-implant tissue; SUPRACRESTAL COMPLEX; AESTHETIC OUTCOMES; SOFT-TISSUES; HEALTH; RESTORATIONS; PLACEMENT; IMPACT; WIDTH; RISK;
D O I
10.1002/cre2.939
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The primary aim of this cross-sectional study was to investigate the association between prosthesis design and peri-implant mucosa dimensions and morphology. The secondary aim was to investigate associations between mucosal dimensions and the presence of mucositis. Materials and Methods Forty-seven patients with 103 posterior bone level implants underwent clinical and radiographic examination, including cone beam computer tomography and intraoral optical scanning. Three-dimensional models for each implant and peri-implant mucosa were constructed. Vertical mucosa height (TH), horizontal mucosa width at implant platform (TW), and 1.5 mm coronal of the platform (TW1.5), as well as mucosal emergence angle (MEA), deep angle (DA), and total contour angle (TA) were measured at six sites for each implant. Results There was a consistent correlation between peri-implant mucosa width and height (beta = 0.217, p < 0.001), with the width consistently surpassing height by a factor of 1.4-2.1. All three angles (MEA, DA, TA) were negatively associated with mucosa height (p < 0.001), while DA was negatively associated with mucosa width (TW1.5) (p < 0.001, beta = -0.02, 95% CI: -0.03, -0.01). There was a significant negative association between bleeding on probing (BoP) and mucosa width at platform (OR 0.903, 95% CI: 0.818-0.997, p = 0.043) and 1.5 coronal (OR 0.877, 95% CI: 0.778-0.989, p = 0.033). Implants with less than half sites positive for BoP (0-2/6) had significantly higher mucosa height (OR 3.51, 95% CI: 1.72-7.14, p = 0.001). Conclusions Prosthesis design can influence the dimensions of the peri-implant mucosa, with wider emergence profile angles associated with reduced peri-implant mucosa height. In particular, a wider deep angle is associated with reduced mucosa width in posterior sites. Reduced peri-implant mucosa height and width are associated with more signs of inflammation.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Dimensions of the healthy gingiva and peri-implant mucosa
    Parpaiola, Andrea
    Cecchinato, Denis
    Toia, Marco
    Bressan, Eriberto
    Speroni, Stefano
    Lindhe, Jan
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (06) : 657 - 662
  • [2] Association of prosthetic angles of the Implant Supracrestal Complex with peri-implant tissue mucositis
    Rungtanakiat, Piboon
    Thitaphanich, Natchaya
    Chengprapakorn, Wareerat
    Janda, Martin
    Arksornnukit, Mansuang
    Mattheos, Nikos
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2023, 9 (03): : 425 - 436
  • [3] Impact of implant overloading on the peri-implant bone in inflamed and non-inflamed peri-implant mucosa
    Kozlovsky, Avital
    Tal, Haim
    Laufer, Ben-Zion
    Leshem, Roy
    Rohrer, Michael D.
    Weinreb, Miron
    Artzi, Zvi
    CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (05) : 601 - 610
  • [4] The influence of peri-implant keratinized mucosa on brushing discomfort and peri-implant tissue health
    Souza, Andre B.
    Tormena, Mariana
    Matarazzo, Flavia
    Araujo, Mauricio G.
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (06) : 650 - 655
  • [5] Managing the Peri-implant Mucosa: A Clinically Reliable Method for Optimizing Soft Tissue Contours and Emergence Profile
    Parpaiola, Andrea
    Sbricoli, Luca
    Guazzo, Riccardo
    Bressan, Eriberto
    Lops, Diego
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2013, 25 (05) : 317 - 323
  • [6] Accurate transfer of peri-implant soft tissue emergence profile from the provisional crown to the final prosthesis using an emergence profile cast
    Elian, Nicolas
    Tabourian, Gerard
    Jalbout, Ziad N.
    Classi, Anthony
    Cho, Sang-Choon
    Froum, Stuart
    Tarnow, Dennis P.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2007, 19 (06) : 306 - 314
  • [7] Peri-implant skin graft for a craniofacial prosthesis
    Anastassov, GE
    Asher, ES
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (02): : 215 - 216
  • [8] Early healing of peri-implant mucosa in man
    Tomasi, Cristiano
    Tessarolo, Francesco
    Caola, Iole
    Piccoli, Federico
    Wennstrom, Jan L.
    Nollo, Giandomenico
    Berglundh, Tord
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2016, 43 (10) : 816 - 824
  • [9] The Role of Keratinized Mucosa in Peri-Implant Health
    Esper, Luis Augusto
    Ferreira, Samuel Barros, Jr.
    Fortes Kaizer, Rosane de Oliveira
    Pompeia Fraga de Almeida, Ana Lucia
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2012, 49 (02): : 167 - 170
  • [10] Reactive Fibrous Hyperplasia of Peri-implant Mucosa
    Bountaniotis, Fotios
    Tzerbos, Fotios
    Tosios, Konstantinos
    Melakopoulos, Ioannis
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (05) : 378 - 379