A COMPARATIVE STUDY OF MEDIUM-SIZED MACULAR HOLE SURGERY WITH INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE VERSUS CONVENTIONAL PEELING

被引:0
|
作者
Iwasaki, Masanori [1 ]
Nakashizuka, Hiroyuki [1 ]
Tanaka, Koji [1 ]
Wakatsuki, Yu [1 ]
Onoe, Hajime [1 ]
Sakakibara, Takuya [1 ]
Nakagawa, Naoya [1 ]
Fujimiya, Taishi [1 ]
Koutari, Sawako [1 ]
Kitagawa, Yorihisa [1 ,2 ]
Takayuki, Hattori [1 ,3 ]
Mori, Ryusaburo [1 ]
Shimada, Hiroyuki [1 ,4 ]
机构
[1] Nihon Univ, Sch Med, Dept Ophthalmol, Tokyo 1018309, Japan
[2] Kobari Gen Hosp, Chiba, Japan
[3] Kasukabe Med Ctr, Kasukabe, Japan
[4] Miyahara Eye Clin, Osaka, Japan
关键词
conventional peeling; high myopia; inverted internal limiting medium-sized macular hole; membrane flap technique; posterior vitreous detachment; primary closure rate; spectral-domain optical coherence tomography; vitrectomy; VISUAL-ACUITY; CLASSIFICATION; VITRECTOMY;
D O I
10.1097/IAE.0000000000004022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The primary closure rate for medium-sized macular holes (251-400 mu m) was significantly higher in the inverted flap group than in the internal limiting membrane (ILM) peeling group (100% [119/119 eyes] vs. 94.6% [139/147 eyes]; P = 0.010). Purpose:To investigate surgical results for medium-sized (251-400 mu m) macular holes (MHs).Methods:This retrospective observational study involved 266 eyes of 262 consecutive patients who underwent internal limiting membrane (ILM) peeling (147 eyes in the ILM peeling group) or inverted ILM flap cover technique (119 eyes in the inverted flap group) for primary medium-sized full-thickness MHs. Macular hole associated with retinal detachment, recurrent MH, and traumatic MH were excluded.Results:The primary closure rate for overall medium-sized MHs was 100% (119 of 119 eyes) in the inverted flap group, which was significantly higher than that (94.6% [139/147 eyes]; P = 0.010) in the ILM peeling group. Notably, even after adjusting for the minimum MH diameter, presence of high myopia, or preexisting posterior vitreous detachment, the primary closure rate was significantly better in the inverted flap group than in the ILM peeling group (Cochran-Mantel-Haenszel test, overall adjusted P = 0.006, 0.009, 0.005, respectively). The preoperative and postoperative restoration of the outer retinal layers and visual acuity were comparable between the inverted ILM flap and ILM peeling techniques.Conclusion:Primary closure for medium-sized MHs was significantly superior in the inverted flap group than in the ILM peeling group.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 50 条
  • [1] Inverted internal limiting membrane flap technique versus complete internal limiting membrane peeling in large macular hole surgery: a comparative study
    Ramtohul, Prithvi
    Parrat, Eric
    Denis, Daniele
    Lorenzi, Umberto
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [2] Inverted internal limiting membrane flap technique versus complete internal limiting membrane peeling in large macular hole surgery: a comparative study
    Prithvi Ramtohul
    Eric Parrat
    Danièle Denis
    Umberto Lorenzi
    BMC Ophthalmology, 20
  • [3] Comparative study of conventional internal limiting membrane peeling versus temporal inverted internal limiting membrane flap for large macular hole treatment
    Kocak, Nurullah
    Yeter, Volkan
    Birinci, Hakki
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (01) : 188 - 194
  • [4] Modification of the inverted flap technique compared to conventional internal limiting membrane peeling in complete macular hole surgery
    Carballes, M. J. Crespo
    Sastre-Ibanez, M.
    Del Cura, M. Prieto
    De Hoz, R.
    Garcia-Saenz, M. C.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (06) : 2275 - 2284
  • [5] CONVENTIONAL INTERNAL LIMITING MEMBRANE PEELING VERSUS INVERTED FLAP FOR SMALL-TO-MEDIUM IDIOPATHIC MACULAR HOLE A Randomized Trial
    Ventre, Luca
    Fallico, Matteo
    Longo, Antonio
    Parisi, Guglielmo
    Russo, Andrea
    Bonfiglio, Vincenza
    Marolo, Paola
    Caselgrandi, Paolo
    Avitabile, Teresio
    Borrelli, Enrico
    Reibaldi, Michele
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (12): : 2251 - 2257
  • [6] Vitrectomy in Small idiopathic MAcuLar hoLe (SMALL) study: conventional internal limiting membrane peeling versus inverted flap
    Fallico, Matteo
    Caselgrandi, Paolo
    Marolo, Paola
    Parisi, Guglielmo
    Borrelli, Enrico
    Ricardi, Federico
    Gelormini, Francesco
    Ceroni, Luca
    Reibaldi, Michele
    EYE, 2024, 38 (17) : 3334 - 3340
  • [7] Anatomical outcome of temporal inverted flap technique versus conventional internal limiting membrane peeling for large macular hole treatment
    Fathy, Khaled
    Magdy, Ahmed
    Shama, Ahmed
    Souka, Ahmed
    ALEXANDRIA JOURNAL OF MEDICINE, 2024, 60 (01) : 327 - 335
  • [8] Multilayered inverted internal limiting membrane flap technique versus standard internal limiting membrane peeling for large macular holes: A comparative study
    Agrawal, Vishal
    Jindal, Khushbu
    Dhakad, Yogendra
    Rathore, Priyanka
    Khilnani, Kamlesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (03) : 909 - 913
  • [9] Comparison of the Inverted Internal Limiting Membrane Flap Technique and the Internal Limiting Membrane Peeling for Macular Hole with Retinal Detachment
    Matsumura, Takehiro
    Takamura, Yoshihiro
    Tomomatsu, Takeshi
    Arimura, Shogo
    Gozawa, Makoto
    Kobori, Akira
    Inatani, Masaru
    PLOS ONE, 2016, 11 (10):
  • [10] Conventional internal limiting membrane peeling versus temporal inverted internal limiting membrane flap for large macular holes
    Avci, Remzi
    Yildiz, Aysegul Mavi
    Yilmaz, Sami
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (02) : 679 - 687