Position sensitive and energy dispersive x-ray detector based on silicon strip detector technology

被引:6
|
作者
Wiacek, P. [1 ]
Dabrowski, W. [1 ]
Fink, J. [2 ]
Fiutowski, T. [1 ]
Krane, H. -G. [2 ]
Loyer, F. [2 ]
Schwamberger, A. [2 ]
Swientek, K. [1 ]
Venanzi, C. [2 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, PL-30059 Krakow, Poland
[2] Bruker AXS GmbH, D-76187 Karlsruhe, Germany
来源
关键词
Si microstrip and pad detectors; Electronic detector readout concepts (solid-state); X-ray fluorescence (XRF) systems; X-ray diffraction detectors; PERFORMANCE;
D O I
10.1088/1748-0221/10/04/P04002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new position sensitive detector with a global energy resolution for the entire detector of about 380 eV FWHM for 8.04 keV line at ambient temperature is presented. The measured global energy resolution is defined by the energy spectra summed over all strips of the detector, and thus it includes electronic noise of the front-end electronics, charge sharing effects, matching of parameters across the channels and other system noise sources. The target energy resolution has been achieved by segmentation of the strips to reduce their capacitance and by careful optimization of the front-end electronics. The key design aspects and parameters of the detector are discussed briefly in the paper. Excellent noise and matching performance of the readout ASIC and negligible system noise allow us to operate the detector with a discrimination threshold as low as 1 keV and to measure fluorescence radiation lines of light elements, down to Al K alpha of 1.49 keV, simultaneously with measurements of the diffraction patterns. The measurement results that demonstrate the spectrometric and count rate performance of the developed detector are presented and discussed in the paper.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] One dimensional detector for X-ray diffraction with superior energy resolution based on silicon strip detector technology
    Dabrowski, W.
    Fink, J.
    Fiutowski, T.
    Krane, H. -G.
    Wiacek, P.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [2] X-ray position-sensitive detector for the energy-dispersive EXAFS spectrometer
    Kovalenko, M
    Mironov, V
    Shaliapin, V
    Tiutiunnikov, S
    JOURNAL OF ALLOYS AND COMPOUNDS, 1999, 286 (1-2) : 26 - 30
  • [3] X-ray holography with a position sensitive detector
    Lausi, A
    Kopecky, M
    Busetto, E
    Savoia, A
    ACTA PHYSICA POLONICA A, 2002, 101 (05) : 621 - 628
  • [4] POSITION-SENSITIVE X-RAY DETECTOR
    GABRIEL, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (10): : 1303 - 1305
  • [5] A position sensitive X-ray detector based on scintillation mosaic
    DalFiume, D
    Labanti, C
    Mauri, A
    Gambaccini, M
    Basili, A
    Landini, G
    Solieri, M
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 757 - 759
  • [6] POSITION-SENSITIVE X-RAY DETECTOR.
    Duval, B.P.
    Barth, J.
    Deslattes, R.D.
    Henins, A.
    Luther, G.G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1983, 222 (1-2) : 274 - 278
  • [7] POSITION SENSITIVE PROPORTIONAL DETECTOR FOR X-RAY CRYSTALLOGRAPHY
    GABRIEL, A
    DUPONT, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (11): : 1600 - &
  • [8] An ''edge-on'' silicon strip detector for X-ray imaging
    Arfelli, F
    Barbiellini, G
    Bonvicini, V
    Bravin, A
    Cantatore, G
    Castelli, E
    DiMichiel, M
    Longo, R
    Olivo, A
    Pani, S
    Pontoni, D
    Poropat, P
    Prest, M
    Rashevsky, A
    Tromba, G
    Vacchi, A
    Zampa, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 874 - 880
  • [9] An ''edge-on'' silicon strip detector for X-ray imaging
    Arfelli, F
    Barbiellini, G
    Bonvicini, V
    Bravin, A
    Cantatore, G
    Castelli, E
    DiMichiel, M
    Longo, R
    Olivo, A
    Pani, S
    Pontoni, D
    Poropat, P
    Prest, M
    Rashevsky, A
    Tromba, G
    Vacchi, A
    Zampa, N
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 237 - 241
  • [10] Silicon Strip Detector with a Polyethylene Converter as a Position Sensitive Detector for Fast Neutrons
    Anokhin, Igor E.
    Zinets, O.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5263 - 5267