Determination of Ambient Air Vaporizers' Performance Based on a Study on Heat Transfer in Longitudinal Finned Tubes

被引:0
|
作者
Lisowski, Filip [1 ]
Lisowski, Edward [2 ]
机构
[1] Cracow Univ Technol, Fac Mech Engn, Dept Machine Design & Composite Struct, Al Jana Pawla II 37, PL-31864 Krakow, Poland
[2] Cracow Univ Technol, Fac Mech Engn, Dept Appl Informat, Al Jana Pawla II 37, PL-31864 Krakow, Poland
关键词
ambient air vaporizers; longitudinal finned tubes; forced convection; CFD analysis; LIQUEFIED NATURAL-GAS; FROST FORMATION; EXCHANGERS; CONVECTION; DESIGN;
D O I
10.3390/en17143579
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Ambient air vaporizers (AVVs) are the most commonly used type of heat exchanger for cryogenic regasification stations. The transfer of heat from the environment for heating the liquefied gas and its vaporization is a cost-free and efficient method. Designing ambient air vaporizers for regasification or fueling stations requires accepting the size and related thermal power of the AVV considering the operating conditions and the type of liquefied gases to be vaporized. The nominal capacity of the ambient air vaporizer depends on its design, the frosting of longitudinal finned tubes, and the airflow through the vaporizer structure. This paper presents the results of experimental studies and computational fluid dynamics (CFD) analysis on determining the heat output of AVV longitudinal finned tubes depending on their design. This experiment was conducted in order to establish a numerical model. The relation between the longitudinal finned tubes thermal power and the air flow velocity is demonstrated and the beneficial effect of forced convection is proved. The obtained results are used for verification calculations of ambient air vaporizers' performance depending on the size of the AVV, the profile cross-section, and the airflow velocity for different liquefied gases. Under conditions of forced convection, profiles with 12 equal-height fins were discovered to be the most efficient for higher airflow velocity providing up to 7% higher heat rate than profiles with 8 equal-height fins. However, at low air velocity, profiles with 8 equal-length fins showed a comparable heat output to profiles with 12 equal-length fins. Profiles with 8 and 12 unequal high fins differ in average heat output by about 28%. The profile with 12 unequal high fins turned out to be the least effective when 2D airflow was considered in this analysis.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Influence of Fins Number and Frosting on Heat Transfer through Longitudinal Finned Tubes of LNG Ambient Air Vaporizers
    Lisowski, Filip
    Lisowski, Edward
    ENERGIES, 2022, 15 (01)
  • [2] Determination of Aerodynamic Drag Coefficients of Longitudinal Finned Tubes of LNG Ambient Air Vaporizers Using CFD and Experimental Methods
    Lisowski, Filip
    Lisowski, Edward
    APPLIED SCIENCES-BASEL, 2022, 12 (21):
  • [3] Research progress on the heat transfer of ambient air LNG vaporizers
    Xu S.
    Gao W.
    Yan R.
    Zhang H.
    Wang Y.
    Yang L.
    Gao, Wenxue (wenxuegao@163.com), 1600, Natural Gas Industry Journal Agency (40): : 130 - 140
  • [4] Influence of Longitudinal Fin Tubes Arrangement in LNG Ambient Air Vaporizers on the Wind Load
    Lisowski, Filip
    Lisowski, Edward
    ENERGIES, 2022, 15 (02)
  • [5] HEAT TRANSFER AT FINNED TUBES
    不详
    KERNTECHNIK ISOTOPENTECHNIK UND CHEMIE, 1965, 7 (05): : 234 - &
  • [6] Heat transfer from finned tubes in a free flow of air
    Elchinov, VP
    Zyuzin, AP
    Kirpikov, VA
    Fedotov, VI
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 1996, 30 (02) : 196 - 199
  • [7] Performance study of spiral finned tubes on heat transfer and wake flow structure
    Yuan, Meng
    Zhang, Wenping
    Liu, Gongmin
    Zhang, Xinyu
    Yousif, Mustafa Z.
    Song, JuHun
    Lim, HeeChang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 196
  • [8] NATURAL-CONVECTION HEAT-TRANSFER ON FINNED TUBES IN AIR
    HAHNE, E
    ZHU, D
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 : 59 - 63
  • [9] Effect of blocked core-tube diameter on heat transfer performance of internally longitudinal finned tubes
    Wang Qiuwang
    Lin Mei
    Zeng Min
    HEAT TRANSFER ENGINEERING, 2008, 29 (01) : 107 - 115
  • [10] Determination of local heat transfer coefficient on the surface of longitudinally finned tubes
    Sobota, T.
    Taler, J.