Pilot-scale performance of gravity-driven ultra-high flux fabric membrane systems for removing small-sized microplastics in wastewater treatment plant effluents

被引:0
|
作者
Oluwoye, Ibukun [1 ,2 ]
Tanaka, Shuhei [1 ]
Okuda, Kensuke [3 ]
机构
[1] Kyoto Univ, Grad Sch Global Environm Studies, Yoshidahonmachi, Kyoto 6068501, Japan
[2] Curtin Univ, Curtin Corros Ctr, GPO Box U1987, Perth, WA 6845, Australia
[3] Metawater R&D Ctr, Water Regenerat Technol Dev Dept, Tokyo 1010041, Japan
基金
日本学术振兴会;
关键词
Microplastic; Wastewater; Surface runoff; WWTP; Fabric membrane; Ultra -high flux; PACKING DENSITY; POLLUTION; ULTRAFILTRATION; PLASTICS; ENVIRONMENT; BIOREACTOR; SEDIMENTS;
D O I
10.1016/j.jenvman.2024.121438
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The ubiquitous nature and environmental impacts of microplastic particles and fibers demand effective solutions to remove such micropollutants from sizable point sources, including wastewater treatment plants and road runoff facilities. While advanced methods, e.g., microfiltration and ultrafiltration, have shown high removal efficiencies of small -sized microplastics (<150 mu m), the low flux encountered in these systems implies high operation costs and makes them less effective in high -capacity wastewater facilities. The issue presents new opportunities for developing cheap high -flux membrane systems, deployable in low -to high -income economies, to remove small -sized microplastic and nanoplastics in wastewater. Here, we report on developing an ultra -high flux gravity -driven fabric membrane system, assessed through a laboratory -scale filtration and large-scale performance in an actual wastewater treatment plant (WWTP). The method followed a carefully designed water sampling, pre-treatment protocol, and analytical measurements involving Fourier transform infrared (FTIR) spectroscopy and laser direct infrared (LDIR) imaging. The result shows that the ultra -high flux (permeance = 550,000 L/m(2)h & sdot;bar) fabric membrane system can effectively remove small -sized microplastics (10-300 mu m) in the secondary effluent of an actual WWTP at high efficiency greater than 96 %. The pilot system demonstrated a continuous treatment capacity of 300,000 L/day through a 1 m(2) surface area disc, with steady removal rates of microplastics. These findings demonstrate the practical, cheap, and sustainable removal of small -sized microplastics in wastewater treatment plants, and their potential value for other large-scale point sources, e.g., stormwater treatment facilities.
引用
收藏
页数:9
相关论文
共 1 条
  • [1] Performance Evaluation of a Pilot-Scale Aerobic Granular Sludge Integrated with Gravity-Driven Membrane System Treating Domestic Wastewater
    Ali, Muhammad
    Singh, Yogesh
    Fortunato, Luca
    Rehman, Zahid Ur
    Manjunath, Sarvajith
    Vrouwenvelder, Johannes S.
    Pronk, Mario
    van Loosdrecht, Mark C. M.
    Saikaly, Pascal E.
    ACS ES&T WATER, 2023, 3 (08): : 2681 - 2690