Treatment of azo dye-containing wastewater in a combined UASB-EMBR system: Performance evaluation and membrane fouling study

被引:0
|
作者
Belli, Tiago Jose [1 ]
Dalbosco, Vlade [2 ]
Bassin, Joao Paulo [3 ]
Lunelli, Karina [1 ]
da Costa, Rayra Emanuelly [2 ]
Lapolli, Flavio Rubens [2 ]
机构
[1] Santa Catarina State Univ, Civil Engn Dept, BR-89140000 Ibirama, SC, Brazil
[2] Univ Fed Santa Catarina, Environm Engn Program, PPGEA, BR-88040900 Florianopolis, SC, Brazil
[3] Univ Fed Rio de Janeiro, Chem Engn Program, COPPE, POB 68502, Rio De Janeiro, RJ, Brazil
关键词
Membrane bioreactor; Upflow anaerobic sludge blanket reactor; Azo dye; Electrocoagulation; Membrane fouling; ELECTROCOAGULATION PROCESS; TEXTILE WASTEWATERS; ELECTRIC-CURRENT; RETENTION TIME; DECOLORIZATION; BIOREACTOR; REMOVAL; BIODEGRADATION; DEGRADATION; REACTOR;
D O I
10.1016/j.jenvman.2024.121701
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work investigated the treatment of azo dye-containing wastewater in an upflow anaerobic sludge blanket (UASB) reactor combined with an electro-membrane bioreactor (EMBR). Current densities of 20 A m- 2 and electric current exposure mode of 6 ' ON/30 ' OFF were applied to compare the performance of the EMBR to a conventional membrane bioreactor (MBR). The results showed that dye (Drimaren Red CL-7B) removal occurred predominantly in the UASB reactor, which accounted for 57% of the total dye removal achieved by the combined system. When the MBR was assisted by electrocoagulation, the overall azo dye removal efficiency increased from 60.5 to 67.1%. Electrocoagulation batch tests revealed that higher decolorization rates could be obtained with a current density of 50 A m- 2. Over the entire experimental period, the combined UASB-EMBR system exhibited excellent performance in terms of chemical oxygen demand (COD) and NH4+-N removal, with average efficiencies above 97%, while PO43--P was only consistently removed when the electrocoagulation was used. Likewise, a consistent reduction in the absorption spectrum of aromatic amines was observed when the MBR was electrochemically assisted. In addition to improving the pollutants removal, the use of electrocoagulation reduced the membrane fouling rate by 68% (0.25-0.08 kPa d-1), while requiring additional energy consumption and operational costs of 1.12 kWh m- 3 and 0.32 USD m- 3, respectively. Based on the results, it can be concluded that the combined UASB-EMBR system emerges as a promising technological approach for textile wastewater treatment.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Combined chemical and biological treatment of azo dye-containing wastewaters
    Liakou, S
    Zissi, U
    Kornaros, M
    Lyberatos, G
    [J]. CHEMICAL ENGINEERING COMMUNICATIONS, 2003, 190 (5-8) : 645 - 661
  • [2] Permselective membrane fouling during azo dye wastewater treatment
    Oduor, Peter G.
    Santos, Xiana
    Abwawo, Jared
    Dunham, Jeffery
    [J]. CLEAN-SOIL AIR WATER, 2008, 36 (02) : 171 - 179
  • [3] Performance of a ZVI-UASB reactor for azo dye wastewater treatment
    Zhang, Yaobin
    Jing, Yanwen
    Zhang, Jingxin
    Sun, Lifang
    Quan, Xie
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2011, 86 (02) : 199 - 204
  • [4] Operation of integrated sequencing batch membrane bioreactor treating dye-containing wastewater at different SRTs: study of overall performance and fouling behavior
    Zonoozi, M. Hasani
    Moghaddam, M. R. Alavi
    Maknoon, R.
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (08) : 5931 - 5942
  • [5] Operation of integrated sequencing batch membrane bioreactor treating dye-containing wastewater at different SRTs: study of overall performance and fouling behavior
    M. Hasani Zonoozi
    M. R. Alavi Moghaddam
    R. Maknoon
    [J]. Environmental Science and Pollution Research, 2015, 22 : 5931 - 5942
  • [6] Enhanced treatment performance of coking wastewater and reduced membrane fouling using a novel EMBR
    Jiang, Bei
    Du, Cong
    Shi, Shengnan
    Tan, Liang
    Li, Meidi
    Liu, Jiaxin
    Xue, Lanlan
    Ji, Xiangyu
    [J]. BIORESOURCE TECHNOLOGY, 2017, 229 : 39 - 45
  • [7] The use of eggshell membrane for the treatment of dye-containing wastewater: Batch, kinetics and reusability studies
    Saratale, Rijuta Ganesh
    Sun, Qianzhe
    Munagapati, Venkata Subbaiah
    Saratale, Ganesh Dattatraya
    Park, Jinhee
    Kim, Dong-Su
    [J]. CHEMOSPHERE, 2021, 281 (281)
  • [8] Evaluation of the treatment performance of lab-scaled vertical flow constructed wetlands in removal of organic compounds, color and nutrients in azo dye-containing wastewater
    Dogdu, Gamze
    Yalcuk, Arda
    [J]. INTERNATIONAL JOURNAL OF PHYTOREMEDIATION, 2016, 18 (02) : 171 - 183
  • [9] RETRACTED: Characteristics of membrane fouling of dye wastewater treatment by combined MBR (Retracted Article)
    Lou Yunpeng
    Tian Qing
    Xin Yiying
    Yang Bo
    Li Fang
    [J]. 2011 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL SCIENCE-ICEES 2011, 2011, 11
  • [10] Performance analysis of a combined system of membrane bioreactor and worm reactor: Wastewater treatment, sludge reduction and membrane fouling
    Tian, Yu
    Lu, Yaobin
    Li, Zhipeng
    [J]. BIORESOURCE TECHNOLOGY, 2012, 121 : 176 - 182