Wearable, disposable and non-enzymatic fluorescence nanosensor for monitoring sweat glucose through smartphone

被引:1
|
作者
Kansay, Vishal [1 ]
Sharma, Varun Dutt [1 ]
Srivastava, Vasu [3 ]
Batra, Neera [3 ]
Chakrabarti, S. [2 ]
Bera, M. K. [1 ]
机构
[1] Maharishi Markandeshwar, Dept Phys, MMEC, Ambala 133207, Haryana, India
[2] Maharishi Markandeshwar, MM Inst Med Sci & Res, Dept Biochem, Ambala 133207, Haryana, India
[3] Maharishi Markandeshwar, Dept Comp Sci & Engn, MMEC, Ambala 133207, Haryana, India
关键词
Carbon quantum dots; Glucose detection; Sweat sensor; Cotton thread microfluidic device; Fluorescent nanosensor; GRAPHENE QUANTUM DOTS; PAPER;
D O I
10.1016/j.microc.2024.110624
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The promise of non-invasive health monitoring has fuelled the development of wearable biosensors for in situ detection of biological analytes in sweat. This paper presents a new fluorescent nanosensor probe based on boric acid functionalized and heteroatom doped carbon quantum dots (CQDs) embedded in paper-based analytical devices and integrated with a hydrophilic cotton thread-based microfluidic channel for the development of a flexible, wearable, biocompatible, and biodegradable sweat sensor for real-time measurement of sweat glucose concentration via smartphone readout. The morphological, physiochemical, compositional, crystallinity, and optical properties of nanosensors were extensively investigated. CQD particle sizes were found to be widely dispersed, ranging from 2.6 to 7.1 nm, with an average diameter of 4.38 nm. A dual response via fluorescence and colorimetric change was demonstrated for on-site sweat glucose monitoring using a smartphone camera to capture images in RGB (red, green, and blue) format and analyse them simultaneously by a customized android app, with quantitative results displayed on the smartphone. The limit of detection value for in situ measurement of sweat glucose concentration was 1.40 to 2.00 mu M (25.25 to 36.13 mu g/dL) and the limit of quantification value was 4.67 to 6.69 mu M (84.16-120.44 mu g/dL) in the pH range of 4.5 to 7.5. The developed sensor's performance metrics were validated using a standard clinical technique, which indicates strong correlation between two methods with Pearson correlation coefficient values of 0.83 and 0.80 for non-diabetic and type- II diabetes patients, respectively. Besides, interference, spike, and recovery studies were carried out with recovery rates ranging from 96.5 to 105.8 %, demonstrating good repeatability and reproducibility. Furthermore, feasible fluorescence quenching processes have been explored. In addition, the disposable and biodegradable nature of the nanosensor probe was studied by throwing it into the soil in the natural environment, where it dissolves almost spontaneously after three weeks.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A wearable non-enzymatic sensor for continuous monitoring of glucose in human sweat
    Chen, Yuhua
    Sun, Yanghan
    Li, Yi
    Wen, Zhuo
    Peng, Xinyu
    He, Yuanke
    Hou, Yuanfang
    Fan, Jingchuan
    Zang, Guangchao
    Zhang, Yuchan
    [J]. TALANTA, 2024, 278
  • [2] Highly sensitive Non-enzymatic, Non-Invasive Disposable Electrochemical Polyaniline Nanocaps based Sweat Sensor for Glucose Monitoring
    Saraswathi, K. A.
    Reddy, M. Sai Bhargava
    Jayarambabu, N.
    Aich, Shampa
    Rao, Tumu Venkatappa
    [J]. MATERIALS LETTERS, 2023, 349
  • [3] Non-enzymatic electrochemical sensor for wearable monitoring of sweat biomarkers: A mini-review
    Liu, Yu
    Liu, Tao
    Jiang, Danfeng
    [J]. CURRENT RESEARCH IN BIOTECHNOLOGY, 2023, 6
  • [4] Continuous glucose monitoring using wearable non-enzymatic sensors in a physiological environment
    Abbasnia Tehrani, Misagh
    Ahmadi, Seyyed Hamid
    Alimohammadi, Somayeh
    Sasanpour, Pezhman
    Batvani, Neda
    Kazemi, Sayed Habib
    Kiani, Mohammad Ali
    [J]. Biosensors and Bioelectronics: X, 2024, 18
  • [5] Applications of Advanced Materials for Non-Enzymatic Glucose Monitoring: From Invasive to the Wearable Device
    Golsanamlou, Zahra
    Mahmoudpour, Mansour
    Soleymani, Jafar
    Jouyban, Abolghasem
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 53 (05) : 1116 - 1131
  • [6] Wearable, robust, non-enzymatic continuous glucose monitoring system and its in vivo investigation
    Yoon, Hyosang
    Xuan, Xing
    Jeong, Sungkwan
    Park, Jae Y.
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 117 : 267 - 275
  • [7] Non-enzymatic continuous glucose monitoring system
    [J]. Song, In-Hyouk (in-hyouk.song@txstate.edu), 2018, John Wiley and Sons Inc (13):
  • [8] Non-enzymatic continuous glucose monitoring system
    Moore, Sean
    You, Byoung Hee
    Kim, Namwon
    Park, Taehyun
    Song, In-Hyouk
    [J]. MICRO & NANO LETTERS, 2018, 13 (08): : 1079 - 1084
  • [9] A non-enzymatic flexible and wearable sensor based on thermal transfer printing technology for continuous glucose detection in sweat
    Liang, Xinshuo
    Zhang, Shuai
    Meng, Shuo
    Tan, Renjie
    Zhang, Ke
    Hu, Jinlian
    [J]. MICROCHEMICAL JOURNAL, 2024, 207
  • [10] Pt/MXene-Based Flexible Wearable Non-Enzymatic Electrochemical Sensor for Continuous Glucose Detection in Sweat
    Li, Quan-Fu
    Chen, Xu
    Wang, Hai
    Liu, Ming
    Peng, Hui-Ling
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (10) : 13290 - 13298