Multiplexed Opto-Microfluidic Biosensing: Advanced Platform for Prostate Cancer Detection

被引:3
|
作者
Funari, Riccardo [2 ]
Chu, Kang-Yu [1 ]
Shen, Amy Q. [3 ]
机构
[1] Grad Univ, Okinawa Inst Sci & Technol, Neurobiol Res Unit, Onna, Okinawa 9040495, Japan
[2] Inst Mech Intelligence, Scuola Super Sant Anna, I-56124 Pisa, Italy
[3] Grad Univ, Okinawa Inst Sci & Technol, Micro Bio Nanofluid Unit, Onna, Okinawa 9040495, Japan
来源
ACS SENSORS | 2024年 / 9卷 / 05期
基金
日本学术振兴会;
关键词
multiplex biosensing; prostate cancer diagnostics; antibody; immunosensor; LSPR; microfluidics; gold electrodeposition; MEMBRANE ANTIGEN; PSA THRESHOLD; BIOMARKERS; IMMUNOHISTOCHEMISTRY; BLOOD; ASSAY; DIAGNOSIS; CELLS; APTASENSOR; UTILITY;
D O I
10.1021/acssensors.4c00312
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cancer stands as a prominent global cause of mortality, necessitating early detection to augment survival rates and alleviate economic burdens on healthcare systems. In particular, prostate cancer (PCa), impacting 1.41 million men globally in 2020, accentuates the demand for sensitive and cost-effective detection methods beyond traditional prostate-specific antigen (PSA) testing. While clinical techniques exhibit limitations, biosensors emerge as compact, user-friendly alternatives to traditional laboratory approaches. However, existing biosensors predominantly concentrate on PSA detection, prompting the necessity for advancing toward multiplex sensing platforms. This study introduces a compact opto-microfluidic sensor featuring a substrate of gold nanospikes, fabricated via electrodeposition, for enhanced sensitivity. Embedded within a microfluidic chip, this nanomaterial enables the precise and concurrent measurement of PSA, alongside two complementary PCa biomarkers, matrix metalloproteinase-2 (MMP-2) and anti-alpha-methylacyl-CoA racemase (anti-AMACR) in diluted human plasma, offering a comprehensive approach to PSA analysis. Taking advantage of the localized surface plasmon resonance principle, this biosensor offers robustness and sensitivity in real sample analysis without the need for labeling agents. With the limit of detection at 0.22, 0.37, and 0.18 ng/mL for PSA, MMP-2, and anti-AMACR, respectively, this biosensing platform holds promise for point-of-care analysis, underscoring its potential impact on medical diagnostics.
引用
收藏
页码:2596 / 2604
页数:9
相关论文
共 50 条
  • [1] Innovative opto-microfluidic platform to manipulate liquid drops and transport micro objects
    Coppola, S.
    Vespini, V.
    Paturzo, M.
    Grilli, S.
    Ferraro, P.
    2011 IEEE PHOTONICS CONFERENCE (PHO), 2011, : 487 - 488
  • [2] Development and optimization of an integrated capillary-based opto-microfluidic device for chemiluminescence quantitative detection
    Honrado, Carlos
    Dong, Tao
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2014, 24 (12)
  • [3] Photo-Induced Electric Field Effects on Water Droplets Generated in a LiNbO3 Opto-Microfluidic Platform
    Bragato, Giovanni
    Zaltron, Annamaria
    Zanardi, Michele
    Zamboni, Riccardo
    De Ros, Maddalena
    Sada, Cinzia
    ADVANCED MATERIALS INTERFACES, 2024, 11 (12)
  • [4] Detection of antibodies against SARS-CoV-2 spike protein by gold nanospikes in an opto-microfluidic chip
    Funari, Riccardo
    Chu, Kang-Yu
    Shen, Amy Q.
    BIOSENSORS & BIOELECTRONICS, 2020, 169
  • [5] Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
    Wang, Ningquan
    Liu, Ruxiu
    Sarioglu, A. Fatih
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2017, (121):
  • [6] A smart microfluidic platform for rapid multiplexed detection of foodborne pathogens
    Azinheiro, Sarah
    Kant, Krishna
    Shahbazi, Mohammad-Ali
    Garrido-Maestu, Alejandro
    Prado, Marta
    Dieguez, Lorena
    FOOD CONTROL, 2020, 114
  • [7] Breast Cancer Diagnosis Using a Microfluidic Multiplexed Immunohistochemistry Platform
    Kim, Minseok S.
    Kim, Taemin
    Kong, Sun-Young
    Kwon, Soim
    Bae, Chae Yun
    Choi, Jaekyu
    Kim, Chul Hwan
    Lee, Eun Sook
    Park, Je-Kyun
    PLOS ONE, 2010, 5 (05):
  • [8] On-site, parallel detection of bio-analytes in water by an integrated capillary flow based opto-microfluidic device
    Pires, Nuno Miguel Matos
    Dong, Tao
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 100 - 105
  • [9] Multiplexed electrical detection of whole viruses from plasma in a microfluidic platform
    Jankelow, Aaron
    Chen, Chih-Lin
    Cowell, Thomas W.
    de los Monteros, Javier Espinosa
    Bian, Zheng
    Kindratenko, Victoria
    Koprowski, Katherine
    Darsi, Sriya
    Han, Hee-Sun
    Valera, Enrique
    Bashir, Rashid
    ANALYST, 2024, 149 (04) : 1190 - 1201
  • [10] Tunable multiplexed fluorescence biosensing platform for simultaneous and selective detection of paraquat and carbendazim pesticides
    Wang, Li
    Haruna, Suleiman A.
    Ahmad, Waqas
    Wu, Jizhong
    Chen, Quansheng
    Ouyang, Qin
    FOOD CHEMISTRY, 2022, 388