BackgroundPatients requiring extraction of infected or dysfunctional cardiac implantable electronic devices (CIED) have high morbidity and mortality. The Micra (TM) leadless cardiac pacemaker (LCP) may be beneficial for patients requiring permanent pacemaker therapy after CIED extraction.MethodsThis study aimed to assess the feasibility, timing and outcomes of LCP implantation in patients who underwent CIED extraction due to infection or dysfunction. The local Micra (TM) LCP registry was reviewed for LCP implantations and CIED extractions.ResultsMicra (TM) LCP implantation was scheduled for 48 consecutive patients (21 women, 44%) undergoing CIED extraction for infection (n = 38, 79%) or dysfunction (n = 10, 21%), and feasible in 47 (98%). Complete CIED removal was feasible in 44 patients (92%) and in 37/38 patients with infected CIED (97%). Overall, 32 LCP (67%) were implanted in a single procedure: 3 (6%) before and 13 (27%) after CIED extraction. LCP were implanted in a single procedure in 24/38 patients (63%) with infected CIED and in 8/10 patients (80%) with dysfunctional CIED. The in-hospital mortality rate was 6% (n = 3), and the survival rates at 30 days, 90 days and 1 year were 94% (n = 45/48), 90% (n = 43/48), and 85% (n = 41/48), respectively. No recurrent LCP-related mortality or infections occurred during a median follow-up of 15 (interquartile range, 12-41) months.ConclusionTwo-thirds of LCPs could be implanted in a single procedure with CIED extraction; no recurrent infections were detected. Overall, Micra (TM) LCP implantation in patients requiring CIED extraction was feasible.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Micra™ leadless cardiac pacemaker implantation in patients with cardiac implantable electronic device extraction
    Kiblboeck, D.
    Blessberger, H.
    Ebner, J.
    Boetscher, J.
    Maier, J.
    Savci, M.
    Schwarz, S.
    Reiter, C.
    Buchmayr, G.
    Wichert-Schmitt, B.
    Steinwender, C.
    Saleh, K.
    WIENER KLINISCHE WOCHENSCHRIFT, 2021, 133 (SUPPL 3) : S140 - S140
  • [2] Leadless Pacemaker Implantation After Transvenous Lead Removal of Infected Cardiac Implantable Electronic Device
    Gwechenberger, M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 212 : 139 - 140
  • [3] Leadless pacemaker implantation after lead extraction for cardiac implanted electronic device infection
    Kowal, Jamia
    Crossley, George H.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (03) : 471 - 472
  • [4] Anticoagulation for patients undergoing implantation of a cardiac implantable electronic device
    Llewellyn, Jennifer
    Ezeonwumelu, Chinenyenwa
    Jackson, Lynsey
    Rao, Archana
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2022, 83 (12)
  • [5] Leadless pacemaker implantation in achondroplastic dwarfism and recurrent cardiac implantable electronic device infections: a case report
    Morani, Giovanni
    Bolzan, Bruna
    Borio, Gianluca
    Tomasi, Luca
    Ribichini, Flavio Luciano
    EUROPACE, 2018, 20 (07): : 1160 - 1160
  • [6] Leadless Cardiac Pacemaker Implantation After Lead Extraction in Patients With Severe Device Infection
    Kypta, Alexander
    Blessberger, Hermann
    Kammler, Juergen
    Lambert, Thomas
    Lichtenauer, Michael
    Brandstaetter, Walter
    Gabriel, Michael
    Steinwender, Clemens
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (09) : 1067 - 1071
  • [7] Outcomes of Leadless Pacemaker Implantation Following Transvenous Lead Removal of Infected Cardiac Implantable Electronic Device: A Systematic Review
    Tan, Min Choon
    Tan, Jian Liang
    Tay, Soon Tzeh
    Sorajja, Dan
    Scott, Luis
    Cha, Yong-Mei
    Russo, Andrea M.
    Hussein, Ayman
    Lee, Justin
    CIRCULATION, 2023, 148
  • [8] Leadless Pacemaker Infection Risk in Patients with Cardiac Implantable Electronic Device Infections: A Case Series and Literature Review
    Bertolino, Lorenzo
    Florio, Letizia Lucia
    Patauner, Fabian
    Gallo, Raffaella
    Peluso, Anna Maria
    Scafuri, Antonio
    De Vivo, Stefano
    Corrado, Carmelina
    Zampino, Rosa
    Ruocco, Giuseppe
    D'Onofrio, Antonio
    Durante-Mangoni, Emanuele
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (24)
  • [9] Outcomes of concurrent and delayed leadless pacemaker implantation following extraction of infected cardiovascular implantable electronic device
    Nadeem, Bilawal
    Sedrakyan, Surik
    Fatima, Amel
    Baig, Mirza Mehmood Ali
    Ahmed, Ali
    Sherwani, Mifrah Rahat Khan
    Wylie, John
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024,
  • [10] Assessment of adverse events stratified by timing of leadless pacemaker implantation with cardiac implantable electronic devices extraction due to infection: A systematic review and meta-analysis
    Inoue, Naoya
    Ito, Yuji
    Imaizumi, Takahiro
    Morikawa, Shuji
    Murohara, Toyoaki
    JOURNAL OF ARRHYTHMIA, 2025, 41 (01)