Quantifying the Dosimetric Impact of Proton Range Uncertainties on RBE-Weighted Dose Distributions in Intensity-Modulated Proton Therapy for Bilateral Head and Neck Cancer

被引:0
|
作者
Rana, Suresh [1 ,2 ]
Padannayil, Noufal Manthala [1 ]
Tran, Linh [3 ]
Rosenfeld, Anatoly B. [3 ]
Saeed, Hina [1 ,2 ]
Kasper, Michael [1 ]
机构
[1] Baptist Hlth South Florida, Boca Raton Reg Hosp, Lynn Canc Inst, Dept Radiat Oncol, Boca Raton, FL 33486 USA
[2] Florida Int Univ, Dept Radiat Oncol, Miami, FL 33199 USA
[3] Univ Wollongong, Ctr Med Radiat Phys CMRP, Wollongong, NSW 2522, Australia
关键词
IMPT; head and neck cancer; variable RBE; RBE-weighted dose; proton therapy; VARIABLE-RBE; BRAIN; MODEL; FRACTIONATION; RADIOTHERAPY; PROSTATE;
D O I
10.3390/curroncol31070272
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: In current clinical practice, intensity-modulated proton therapy (IMPT) head and neck cancer (HNC) plans are generated using a constant relative biological effectiveness (cRBE) of 1.1. The primary goal of this study was to explore the dosimetric impact of proton range uncertainties on RBE-weighted dose (RWD) distributions using a variable RBE (vRBE) model in the context of bilateral HNC IMPT plans. Methods: The current study included the computed tomography (CT) datasets of ten bilateral HNC patients who had undergone photon therapy. Each patient's plan was generated using three IMPT beams to deliver doses to the CTV_High and CTV_Low for doses of 70 Gy(RBE) and 54 Gy(RBE), respectively, in 35 fractions through a simultaneous integrated boost (SIB) technique. Each nominal plan calculated with a cRBE of 1.1 was subjected to the range uncertainties of +/- 3%. The McNamara vRBE model was used for RWD calculations. For each patient, the differences in dosimetric metrices between the RWD and nominal dose distributions were compared. Results: The constrictor muscles, oral cavity, parotids, larynx, thyroid, and esophagus showed average differences in mean dose (Dmean) values up to 6.91 Gy(RBE), indicating the impact of proton range uncertainties on RWD distributions. Similarly, the brachial plexus, brain, brainstem, spinal cord, and mandible showed varying degrees of the average differences in maximum dose (Dmax) values (2.78-10.75 Gy(RBE)). The Dmean and Dmax to the CTV from RWD distributions were within +/- 2% of the dosimetric results in nominal plans. Conclusion: The consistent trend of higher mean and maximum doses to the OARs with the McNamara vRBE model compared to cRBE model highlighted the need for consideration of proton range uncertainties while evaluating OAR doses in bilateral HNC IMPT plans.
引用
收藏
页码:3690 / 3697
页数:8
相关论文
共 50 条
  • [1] Dosimetric Impact of Spot Delivery Positional Uncertainties in Intensity Modulated Proton Therapy for the Head and Neck
    Zhang, B.
    Sabouri, P.
    Mossahebi, S.
    Chen, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E348 - E348
  • [2] Dosimetric Impact of Beam Size for Intensity Modulated Proton Therapy in Head and Neck Cancer
    Baba, H.
    Hotta, K.
    Tachibana, H.
    Kumagai, M.
    Sugama, Y.
    Akimoto, T.
    MEDICAL PHYSICS, 2017, 44 (06) : 2865 - 2865
  • [3] Intensity-modulated proton therapy (IMPT) versus intensity-modulated radiation therapy (IMRT) for the treatment of head and neck cancer: A dosimetric comparison
    Nguyen, My-Lien
    Cantrell, J. Nathan
    Ahmad, Salahuddin
    Henson, Christina
    MEDICAL DOSIMETRY, 2021, 46 (03) : 259 - 263
  • [4] RBE-weighted dose and its impact on the risk of acute coronary event for breast cancer patients treated with intensity modulated proton therapy
    Liu, Chunbo
    Bradley, Julie A.
    Zheng, Dandan
    Vega, Raymond B. Mailhot
    Beltran, Chris J.
    Mendenhall, Nancy
    Liang, Xiaoying
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (04):
  • [5] Reformulated McNamara RBE-weighted beam orientation optimization for intensity modulated proton therapy
    Ramesh, Pavitra
    Lyu, Qihui
    Gu, Wenbo
    Ruan, Dan
    Sheng, Ke
    MEDICAL PHYSICS, 2022, 49 (04) : 2136 - 2149
  • [6] Variance-based sensitivity analysis for uncertainties in proton therapy: A framework to assess the effect of simultaneous uncertainties in range, positioning, and RBE model predictions on RBE-weighted dose distributions
    Hofmaier, Jan
    Dedes, George
    Carlson, David J.
    Parodi, Katia
    Belka, Claus
    Kamp, Florian
    MEDICAL PHYSICS, 2021, 48 (02) : 805 - 818
  • [7] Proton grid therapy: LET and variable RBE-weighted dose distributions for interlaced beams
    Oden, J.
    Henry, T.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1063 - S1064
  • [8] Impact of Uncertainties in Robust Optimization for Head and Neck Intensity Modulated Proton Therapy
    Dogan, N.
    Padgett, K.
    Butkus, M.
    Xu, Y.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1712 - S1713
  • [9] Secondary cancer risk in head-and-neck cancer patients: A comparison of RBE-weighted proton therapy and photon therapy
    Dasiukevich, Peter
    Tattenberg, Sebastian
    Hoehr, Cornelia
    Hammi, Abdelkhalek
    MEDICAL PHYSICS, 2025,
  • [10] Unilateral and bilateral neck SIB for head and neck cancer patients Intensity-modulated proton therapy, tomotherapy, and RapidArc
    Stromberger, Carmen
    Cozzi, Luca
    Budach, Volker
    Fogliata, Antonella
    Ghadjar, Pirus
    Wlodarczyk, Waldemar
    Jamil, Basil
    Raguse, Jan D.
    Boettcher, Arne
    Marnitz, Simone
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (04) : 232 - 239