Methamphetamine detection using portable capillary electrophoresis coupled with a swab-based extraction device

被引:0
|
作者
Atia, Mostafa A. [1 ,2 ]
Kalsoom, Umme [3 ]
Ollerton, Samantha [3 ,4 ]
Haddad, Paul R. [1 ]
Breadmore, Michael C. [1 ]
机构
[1] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Sch Nat Sci, Private Bag 75, Hobart, Tas 7001, Australia
[2] Helwan Univ, Fac Pharm, Dept Analyt Chem, Cairo 11795, Egypt
[3] GreyScan, 9-435 Williamstown Rd, Port Melbourne, Vic 3207, Australia
[4] Precis Plus Consulting Ltd, 71-75 Shelton St, London WC2H 9HJ, England
关键词
Portable capillary electrophoresis; Conductivity detection; Swabbing; Clandestine laboratories; Methamphetamine; Pseudoephedrine; CONTACTLESS CONDUCTIVITY; ZONE-ELECTROPHORESIS; ORAL FLUID; DRUGS; SEPARATION; URINE; AUSTRALIA; SAMPLES;
D O I
10.1016/j.talanta.2024.126357
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methamphetamine (MA) is one of the most virulent illicit drugs that can be synthesized from household materials leading to its prevalent trafficking and local manufacturing in clandestine drug laboratories (clan labs). The significant problems of tracing MA in clan labs and monitoring drug abusers lie in the lag time between sample collection and analysis and the number of tests done. Capillary electrophoresis (CE) is a rapid separation technique amenable to miniaturization and field testing. Herein, we developed a simple transient isotachophoretic (tITP)-CE method to detect MA and its precursor pseudoephedrine (PSE) in clan labs and non-invasive biological fluids. The method was implemented on the ETD-100, a commercial fully automated portable CE instrument with an integrated swab-based extraction system. Within 2 min of insertion of the swab, MA and PSE were automatically extracted with a leading electrolyte (LE) and then separated on covalently modified capillaries. The ETD-100 showed a limit of detection (LOD) and quantification (LOQ) of MA 0.02 and 0.05 mu g/swab and 0.02 and 0.06 mu g/swab of PSE, with an enhancement factor of 118 and 328, respectively, when compared to a normal nontITP injection. The intra and inter-day relative standard deviation in terms of migration time were in the range of 0.75-1.93 % for both MA and PSE and were 2.0-2.4 % for both MA and PSE peak height. The method was demonstrated with the detection of spiked MA and PSE on different household materials as well as in noninvasive biological fluids with a recovery above 60 %.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Portable capillary electrophoresis coupled with swab-based extraction device for cleaning validation in pharmaceutical facilities
    Atia, Mostafa A.
    Amuno, Ria Marni
    Kalsoom, Umme
    Ollerton, Samantha
    Rhoden, Alan
    Haddad, Paul R.
    Breadmore, Michael C.
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1688
  • [2] Portable Microcoil NMR Detection Coupled to Capillary Electrophoresis
    Diekmann, Joana
    Adams, Kristl L.
    Klunder, Gregory L.
    Evans, Lee
    Steele, Paul
    Vogt, Carla
    Herberg, Julie L.
    ANALYTICAL CHEMISTRY, 2011, 83 (04) : 1328 - 1335
  • [3] Portable capillary electrophoresis instrument with potentiometric detection
    Kappes, T
    Hauser, PC
    ANALYTICAL COMMUNICATIONS, 1998, 35 (10): : 325 - 329
  • [4] Capillary electrophoresis coupled to biosensor detection
    Bossi, A
    Piletsky, SA
    Righetti, PG
    Turner, APF
    JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) : 143 - 153
  • [5] Chemiluminescence detection coupled to capillary electrophoresis
    Garcia-Campana, Ana M.
    Lara, Francisco J.
    Gamiz-Gracia, Laura
    Huertas-Perez, Jose F.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (08) : 973 - 986
  • [6] A novel thread-based microfluidic device for capillary electrophoresis with capacitively coupled contactless conductivity detection
    Quero, Reverson Fernandes
    Bressan, Lucas Paines
    Fracassi da Silva, Jose Alberto
    de Jesus, Dosil Pereira
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 286 : 301 - 305
  • [7] Trace determination of perchlorate using electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection
    Kiplagat, Isaac K.
    Thi Kieu Oanh Doan
    Kuban, Pavel
    Bocek, Petr
    ELECTROPHORESIS, 2011, 32 (21) : 3008 - 3015
  • [8] Recent advances in chemiluminescence detection coupled with capillary electrophoresis and microchip capillary electrophoresis
    Liu, Yuxuan
    Huang, Xiangyi
    Ren, Jicun
    ELECTROPHORESIS, 2016, 37 (01) : 2 - 18
  • [9] FLUORESCENCE DETECTION IN CAPILLARY ZONE ELECTROPHORESIS USING A CHARGE-COUPLED DEVICE WITH TIME-DELAYED INTEGRATION
    SWEEDLER, JV
    SHEAR, JB
    FISHMAN, HA
    ZARE, RN
    SCHELLER, RH
    ANALYTICAL CHEMISTRY, 1991, 63 (05) : 496 - 502
  • [10] Determination of inorganic cations in biological fluids using a hybrid capillary electrophoresis device coupled with contactless conductivity detection
    Lobo-Junior, Eulicio Oliveira
    Chagas, Cyro L. S.
    Coltro, Wendell K. T.
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (16) : 3310 - 3317