Numerical investigation of flow boiling characteristics in narrow rectangular channels using two-fluid Eulerian CFD model covering a wide range of pressures

被引:0
|
作者
Han, Jinyu [1 ]
He, Wen [1 ]
Liu, Yao [1 ]
Gao, Deyang [1 ]
Zhao, Chenru [1 ]
Bo, Hanliang [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Adv Nucl Energy Technol Cooperat Innovat Ctr, Key Lab Adv Nucl Engn & Safety,Minist Educ, Beijing 100084, Peoples R China
关键词
CFD; Flow boiling; Wall boiling model; Narrow rectangular channel; NUCLEATION SITE DENSITY; BUBBLE DEPARTURE DIAMETER; AREA TRANSPORT-EQUATION; NET VAPOR GENERATION; CRITICAL HEAT-FLUX; 2-PHASE FLOW; INTERFACIAL AREA; VOID FRACTION; VERTICAL CHANNELS; PREDICTION;
D O I
10.1016/j.applthermaleng.2024.123982
中图分类号
O414.1 [热力学];
学科分类号
摘要
Narrow channel heat exchange technology is one of the key technologies for the development of integrated small modular reactors (SMR). The 'wall heat flux partitioning' (WHFP) model in conjunction with an Eulerian-Eulerian Multiphase Flow (EEMF) method is found to be an important tool for two-phase hydrothermal analysis. In this paper, the accuracy of the EEMF-WHFP method with various sub-models is systemically evaluated over a large database of boiling flows in narrow rectangular channels. Prediction results using a total of 9 model combinations, are compared with data from 22 experimental conditions covering a range of the mass flux of 134.2 to 2200 kgm-2s-1, the inlet fluid subcooling of 7.2 to 74.2 K, the pressure of 0.1 to 14 MPa and the heat flux of 9.54 to 1700 kWm-2 in narrow rectangular channels with gaps of 1.0 to 3.0 mm. The evolution of distributions of void fraction, wall temperature and the net vapor generation (NVG) point along the flow channel is simulated and compared with experimental data. It is found that due to the limitation of the range of applicability of sub-models, certain models produced better prediction results under different pressure ranges than others, and the recommended combinations are given according to the quantitative assessments. In addition, the ability of the model combinations to predict the NVG point, as well as the flow structure and boiling process in narrow channels is investigated. The critical local void fraction near the wall at the NVG point is quantitatively estimated based on numerical results. The research conclusions in this paper can be used in thermal-hydraulic calculations in a wide range of operating pressures covering the applications of compact heat exchangers, flat plate fuels, climbing/falling film plate evaporators and the cooling of microelectronics, among other applications.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Numerical Investigation of Flow Boiling Characteristics Using Two-Fluid Eulerian CFD Model in Narrow Rectangular Channel
    Han, Jinyu
    Liu, Yao
    Zhao, Chenru
    Bo, Hanliang
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (10): : 3151 - 3159
  • [2] Prediction of subcooled flow boiling characteristics using two-fluid Eulerian CFD model
    Braz Filho, Francisco A.
    Ribeiro, Guilherme B.
    Caldeira, Alexandre D.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2016, 308 : 30 - 37
  • [3] Numerical investigation of hydrogen flow boiling based on two-fluid model
    Kuang Y.
    Sun L.
    Wang W.
    Zhuan R.
    Zhang L.
    [J]. Huagong Xuebao/CIESC Journal, 2021, 72 : 184 - 193
  • [4] Numerical investigation of boiling flow of nitrogen in a vertical tube using the two-fluid model
    Li, Xiangdong
    Wang, Rongshun
    Huang, Rongguo
    Shi, Yumei
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) : 2425 - 2432
  • [5] Investigation of Wall Boiling Closure, Momentum Closure and Population Balance Models for Refrigerant Gas-Liquid Subcooled Boiling Flow in a Vertical Pipe Using a Two-Fluid Eulerian CFD Model
    Shaparia, Nishit
    Pelay, Ugo
    Bougeard, Daniel
    Levasseur, Aurelien
    Francois, Nicolas
    Russeil, Serge
    [J]. ENERGIES, 2024, 17 (17)
  • [6] CFD simulation of upward subcooled boiling flow of refrigerant-113 using the two-fluid model
    Chen, Erfeng
    Li, Yanzhong
    Cheng, Xianghua
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (11-12) : 2508 - 2517
  • [7] Validation of two-fluid Eulerian CFD modeling for microbubble drag reduction across a wide range of Reynolds numbers
    Kunz, Robert F.
    Gibeling, Howard J.
    Maxey, Martin R.
    Tryggvason, Gretar
    Fontaine, Arnold A.
    Petrie, Howard L.
    Ceccio, Steven L.
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (01): : 66 - 79
  • [8] Numerical modeling of slug flow initiation in a horizontal channels using a two-fluid model
    Ansari, M. R.
    Shokri, V.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2011, 32 (01) : 145 - 155
  • [9] Validation of the Eulerian-Eulerian Two-Fluid Method and the RPI Wall Partitioning Model Predictions in OpenFOAM with Respect to the Flow Boiling Characteristics within Conventional Tubes and Micro-Channels
    Vontas, Konstantinos
    Pavarani, Marco
    Miche, Nicolas
    Marengo, Marco
    Georgoulas, Anastasios
    [J]. ENERGIES, 2023, 16 (13)
  • [10] Numerical investigation of two-phase flow characteristics of subcooled boiling in IC engine cooling passages using a new 3D two-fluid model
    Hua, Shiyang
    Huang, Ronghua
    Zhou, Pei
    [J]. APPLIED THERMAL ENGINEERING, 2015, 90 : 648 - 663