Accuracy of semi-occlusive CAD/CAM titanium mesh using the reverse guided bone regeneration digital protocol: A preliminary clinical study

被引:0
|
作者
Pellegrino, Gerardo [1 ]
Vignudelli, Elisabetta [1 ,2 ]
Barausse, Carlo [1 ]
Bonifazi, Lorenzo [1 ,3 ]
Renzi, Teo [1 ]
Tayeb, Subhi [1 ]
Felice, Pietro [1 ]
机构
[1] Univ Bologna, Dept Biomed & Neuromotor Sci DIBINEM, Unit Oral Surg, Alma Mater Studiorum, Bologna, Italy
[2] Univ Brescia, Brescia, Italy
[3] Univ Bari Aldo Moro, Dept Interdisciplinary Med, Complex Unit Odontostomatol, Bari, Italy
关键词
accuracy; CAD/CAM; guided bone regeneration; preliminary results; titanium mesh; VERTICAL RIDGE AUGMENTATION; IMPLANT PLACEMENT; OSSEOINTEGRATED IMPLANTS; REHABILITATION; COMPLICATIONS; MEMBRANES; ARCHES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The reverse guided bone regeneration protocol is a digital workflow that has been introduced to reduce the complexity of guided bone regeneration and promote prosthetically guided bone reconstruction with a view to achieving optimal implant placement and prosthetic finalisation. The aim of the present study was to investigate the accuracy of this digital protocol. Materials and methods: Sixteen patients with partial edentulism in the maxilla or mandible and with vertical or horizontal bone defects were treated using the reverse guided bone regeneration protocol to achieve fixed implant rehabilitations. For each patient, a digital wax-up of the future rehabilitation was created and implant planning was carried out, then the necessary bone reconstruction was simulated virtually and the CAD/CAM titanium mesh was designed and used to perform guided bone regeneration. The computed tomography datasets from before and after guided bone regeneration were converted into 3D models and aligned digitally. The actual position of the mesh was compared to the virtual position to assess the accuracy of the digital project. Surgical and healing complications were also recorded. A descriptive analysis was conducted and a one-sample t test and Wilcoxon test were utilised to assess the statistical significance of the accuracy. The level of significance was set at 0.05. Results: A total of 16 patients with 16 treated sites were enrolled. Comparing the virtually planned mesh position with the actual position, an overall mean discrepancy between the two of 0.487 +/- 0.218 mm was achieved. No statistically significant difference was observed when comparing this to a predefined minimum tolerance (P = 0.06). No surgical complications occurred, but two healing complications were recorded (12.5%). Conclusion: Within the limitations of the present study, the reverse guided bone regeneration digital protocol seems to be able to achieve good accuracy in reproducing the content of the virtual plan. Nevertheless, further clinical comparative studies are required to confirm these results.
引用
收藏
页码:175 / 185
页数:11
相关论文
共 9 条
  • [1] Semi-occlusive CAD/CAM titanium mesh for guided bone regeneration: Preliminary clinical and histological results
    Simion, Massimo
    Pistilli, Roberto
    Vignudelli, Elisabetta
    Pellegrino, Gerardo
    Barausse, Carlo
    Bonifazi, Lorenzo
    Roccoli, Lorenzo
    Lezzi, Giovanna
    Felice, Pietro
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2023, 16 (04) : 327 - 336
  • [2] Customized CAD/CAM titanium meshes for the guided bone regeneration of severe alveolar ridge defects: Preliminary results of a retrospective clinical study in humans
    Chiapasco, Matteo
    Casentini, Paolo
    Tommasato, Grazia
    Dellavia, Claudia
    Del Fabbro, Massimo
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) : 498 - 510
  • [3] Prosthetically CAD-CAM-Guided Bone Augmentation of Atrophic Jaws Using Customized Titanium Mesh: Preliminary Results of an Open Prospective Study
    Ciocca, Leonardo
    Lizio, Giuseppe
    Baldissara, Paolo
    Sambuco, Alessandro
    Scotti, Roberto
    Corinaldesi, Giuseppe
    JOURNAL OF ORAL IMPLANTOLOGY, 2018, 44 (02) : 131 - 137
  • [4] Evaluation of surgical placement accuracy of customized CAD/CAM titanium mesh using screws-position-guided template: A retrospective comparative study
    Chen, Dan
    Zheng, Lingling
    Wang, Chao
    Huang, Yuanding
    Huang, Haitao
    Apicella, Antonio
    Hu, Guiping
    Wang, Lizhen
    Fan, Yubo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (03) : 519 - 531
  • [5] Evaluation of Risk Parameters in Bone Regeneration Using a Customized Titanium Mesh: Results of a Clinical Study
    Hartmann, Amely
    Hildebrandt, Helmut
    Schmohl, Joerg U.
    Kaemmerer, Peer W.
    IMPLANT DENTISTRY, 2019, 28 (06) : 543 - 550
  • [6] Micro-computed tomography analysis of early stage bone healing using micro-porous titanium mesh for guided bone regeneration: preliminary experiment in a canine model
    Rakhmatia, Yunia Dwi
    Ayukawa, Yasunori
    Jinno, Yohei
    Furuhashi, Akihiro
    Koyano, Kiyoshi
    ODONTOLOGY, 2017, 105 (04) : 408 - 417
  • [7] Micro-computed tomography analysis of early stage bone healing using micro-porous titanium mesh for guided bone regeneration: preliminary experiment in a canine model
    Yunia Dwi Rakhmatia
    Yasunori Ayukawa
    Yohei Jinno
    Akihiro Furuhashi
    Kiyoshi Koyano
    Odontology, 2017, 105 : 408 - 417
  • [8] Guided bone regeneration using titanium mesh to augment 3-dimensional alveolar defects prior to implant placement. A pilot study
    Lizio, Giuseppe
    Pellegrino, Gerardo
    Corinaldesi, Giuseppe
    Ferri, Agnese
    Marchetti, Claudio
    Felice, Pietro
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (06) : 607 - 621
  • [9] The Influence of Surgical Experience and Bone Density on the Accuracy of Static Computer-Assisted Implant Surgery in Edentulous Jaws Using a Mucosa-Supported Surgical Template with a Half-Guided Implant Placement Protocol-A Randomized Clinical Study
    Kivovics, Marton
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    MATERIALS, 2020, 13 (24) : 1 - 12