Breast density effect on the sensitivity of digital screening mammography in a UK cohort

被引:0
|
作者
Payne, Nicholas R. [1 ]
Hickman, Sarah E. [1 ,2 ]
Black, Richard [3 ]
Priest, Andrew N. [1 ,3 ]
Hudson, Sue [4 ]
Gilbert, Fiona J. [1 ,3 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Sch Clin Med, Dept Radiol, Box 218 Cambridge Biomed Campus, Cambridge CB2 0QQ, England
[2] Royal London Hosp, Dept Radiol, Barts Hlth NHS Trust, 80 Newark St, London E1 2ES, England
[3] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Dept Radiol, Cambridge, England
[4] Peel & Schriek Consulting Ltd, London, England
关键词
Mammographic breast density; Digital mammography; Early detection of cancer; CANCER; RISK; VARIABILITY; WOMEN; MRI;
D O I
10.1007/s00330-024-10951-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To assess the performance of breast cancer screening by category of breast density and age in a UK screening cohort. Methods Raw full-field digital mammography data from a single site in the UK, forming a consecutive 3-year cohort of women aged 50 to 70 years from 2016 to 2018, were obtained retrospectively. Breast density was assessed using Volpara software. Examinations were grouped by density category and age group (50-60 and 61-70 years) to analyse screening performance. Statistical analysis was performed to determine the association between density categories and age groups. Volumetric breast density was assessed as a binary classifier of interval cancers (ICs) to find an optimal density threshold. Results Forty-nine thousand nine-hundred forty-eight screening examinations (409 screen-detected cancers (SDCs) and 205 ICs) were included in the analysis. Mammographic sensitivity, SDC/(SDC + IC), decreased with increasing breast density from 75.0% for density a (p = 0.839, comparisons made to category b), to 73.5%, 59.8% (p = 0.001), and 51.3% (p < 0.001) in categories b, c, and d, respectively. IC rates were highest in the densest categories with rates of 1.8 (p = 0.039), 3.2, 5.7 (p < 0.001), and 7.9 (p < 0.001) per thousand for categories a, b, c, and d, respectively. The recall rate increased with breast density, leading to more false positive recalls, especially in the younger age group. There was no significant difference between the optimal density threshold found, 6.85, and that Volpara defined as the b/c boundary, 7.5. Conclusions The performance of screening is significantly reduced with increasing density with IC rates in the densest category four times higher than in women with fatty breasts. False positives are a particular issue for the younger subgroup without prior examinations. Clinical relevance statement In women attending screening there is significant underdiagnosis of breast cancer in those with dense breasts, most marked in the highest density category but still three times higher than in women with fatty breasts in the second highest category.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Digital mammography screening: sensitivity of the programme dependent on breast density
    Stefanie Weigel
    W. Heindel
    J. Heidrich
    H.-W. Hense
    O. Heidinger
    [J]. European Radiology, 2017, 27 : 2744 - 2751
  • [2] Digital mammography screening: sensitivity of the programme dependent on breast density
    Weigel, Stefanie
    Heindel, W.
    Heidrich, J.
    Hense, H. -W.
    Heidinger, O.
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (07) : 2744 - 2751
  • [3] The influence of breast density on the sensitivity of mammography screening
    Verbeek, A. L. M.
    [J]. EJC SUPPLEMENTS, 2004, 2 (03): : 57 - 57
  • [4] Breast density and outcome of mammography screening: a cohort study
    Olsen, A. H.
    Bihrmann, K.
    Jensen, M-B
    Vejborg, I.
    Lynge, E.
    [J]. BRITISH JOURNAL OF CANCER, 2009, 100 (07) : 1205 - 1208
  • [5] Effect of Mammographic Screening Modality on Breast Density Assessment: Digital Mammography versus Digital Breast Tomosynthesis
    Gastounioti, Aimilia
    McCarthy, Anne Marie
    Pantalone, Lauren
    Synnestvedt, Marie
    Kontos, Despina
    Conant, Emily F.
    [J]. RADIOLOGY, 2019, 291 (02) : 319 - 326
  • [6] Breast density and outcome of mammography screening: a cohort study
    A H Olsen
    K Bihrmann
    M-B Jensen
    I Vejborg
    E Lynge
    [J]. British Journal of Cancer, 2009, 100 : 1205 - 1208
  • [7] Effect of age, breast density, and family history on the sensitivity of first screening mammography
    Kerlikowske, K
    Grady, D
    Barclay, J
    Sickles, EA
    Ernster, V
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (01): : 33 - 38
  • [8] The effect of age and breast density on the sensitivity of mammography
    AM Kavanagh
    GB Byrnes
    J Hopper
    GG Giles
    DM Gertig
    JN Cawson
    G Marr
    [J]. Breast Cancer Research, 6 (Suppl 1)
  • [9] Relationship of Breast Density and Age in a Cohort of Screening Mammography Patients
    Copit, D.
    Gluskin, J.
    Fishman, M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [10] Volumetric breast density affects performance of digital screening mammography
    Wanders, Johanna O. P.
    Holland, Katharina
    Veldhuis, Wouter B.
    Mann, Ritse M.
    Pijnappel, Ruud M.
    Peeters, Petra H. M.
    van Gils, Carla H.
    Karssemeijer, Nico
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2017, 162 (01) : 95 - 103