Inter-rater reliability of the dynamic neuromuscular stabilization diaphragm tests among individuals with non-specific low back pain and neck pain

被引:0
|
作者
Sannasi, Rajasekar [1 ]
Morris, Craig E. [2 ]
Busch, Andrew [3 ]
Noronha, Thrishala [1 ]
Krishna, Vidhya [1 ]
Stribrny, Martin [4 ,5 ]
Kobesova, Alena [4 ,5 ]
机构
[1] Srinivas Univ, Inst Physiotherapy, Mangaluru, Karnataka, India
[2] Rehabil Prague Sch, Prague, Czech Republic
[3] Ohio Wesleyan Univ, Dept Hlth & Human Kinet, Delaware, OH USA
[4] Charles Univ Prague, Fac Med 2, Dept Rehabil & Sports Med, Prague, Czech Republic
[5] Univ Hosp Motol, Prague, Czech Republic
关键词
Diaphragm; Postural-respiratory function; Postural stabilization; Inter-rater; Reliability; Back pain; Neck pain; POSTURAL CONTROL; MECHANISM; MOVEMENT; BALANCE;
D O I
10.1016/j.msksp.2024.102949
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: The Dynamic Neuromuscular Stabilization (DNS) diaphragm test and intra-abdominal pressure regulation test (IAPRT) are qualitative clinical tests that assess postural stability provided by the diaphragm. Objective: Evaluate the inter -rater reliability of the diaphragm test and IAPRT between an experienced and novice DNS clinician among individuals with non-specific low back pain (LBP) and neck pain. Methods: Forty-five participants with non-specific LBP and/or neck pain were assessed by an experienced and novice DNS physiotherapist in the diaphragm test and IAPRT, and scored on a visual analog scale (VAS) according to five different criteria. Results: Moderate reliability was noted when assessing LBP and neck pain patients in the diaphragm test and IAPRT (p < 0.001). Moderate reliability also existed when assessing only LBP (p < 0.001) or neck pain (p = 0.002, p = 0.009) independently. Patients with lower pain (NPRS score of 5 or < ) demonstrated lower intra-class correlation coefficients, yet still moderate reliability in the diaphragm test (p = 0.004) and IAPRT (p = 0.001). Patients with higher pain (NPRS score of 6 or > ) demonstrated greater intra-class correlation coefficients, with the diaphragm test resulting in good reliability (p < 0.001). Conclusions: The diaphragm test and IAPRT demonstrate moderate reliability between an experienced and novice DNS clinician when evaluating LBP and neck pain patients, with a greater degree of reliability noted in patients suffering from higher reported pain.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Intra-rater and inter-rater reliability of neutral and target lumbar positioning tests in subjects with and without non-specific lower back pain
    Reddy, Ravi Shankar
    Alahmari, Khalid A.
    Samuel, Paul Silvian
    Tedla, Jaya Shanker
    Kakaraparthi, Venkata Nagaraj
    Rengaramanujam, Kanagaraj
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2021, 34 (02) : 289 - 299
  • [2] Inter-rater reliability of pressure biofeedback unit among individuals with and without chronic low back pain
    Khan, Muhammad
    Zafar, Hamayun
    Gilani, Syed Amir
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (04) : 987 - 991
  • [3] Inter-rater reliability of three standardized functional tests in patients with low back pain
    Tidstrand, Johan
    Horneij, Eva
    BMC MUSCULOSKELETAL DISORDERS, 2009, 10
  • [4] Inter-rater reliability of three standardized functional tests in patients with low back pain
    Johan Tidstrand
    Eva Horneij
    BMC Musculoskeletal Disorders, 10
  • [5] Inter-rater reliability of classification systems in chronic low back pain populations
    Flavell, Carol
    Gordon, Susan
    Marshman, Laurence
    Watt, Kerrianne
    PHYSICAL THERAPY REVIEWS, 2014, 19 (03) : 204 - 212
  • [6] Inter-rater reliability of McKenzie assessment in patients with neck pain
    Dionne, Carol P.
    Bybee, Ronald F.
    Tomaka, Joe
    PHYSIOTHERAPY, 2006, 92 (02) : 75 - 82
  • [7] Inter-Rater Reliability of Neck Reflex Points in Women with Chronic Neck Pain
    Weinschenk, Stefan
    Goellner, Richard
    Hollmann, Markus W.
    Hotz, Lorenz
    Picardi, Susanne
    Hubbert, Katharina
    Strowitzki, Thomas
    Meuser, Thomas
    FORSCHENDE KOMPLEMENTARMEDIZIN, 2016, 23 (04): : 223 - 229
  • [8] Intra- and Inter-Rater Reliability of Three Measurements for Assessing Tactile Acuity in Individuals with Chronic Low Back Pain
    Wang, Juan
    Chen, Changcheng
    Peng, Mengsi
    Wang, Yizu
    Wu, Bao
    Zheng, Yili
    Wang, Xueqiang
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2020, 2020
  • [9] Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review
    Jonsson, Anders
    Rasmussen-Barr, Eva
    PHYSIOTHERAPY THEORY AND PRACTICE, 2018, 34 (03) : 165 - 180
  • [10] Intra- and inter-rater reliability, standard error of measurement, and minimal detectable change of the cranio-cervical flexion test in individuals with non-specific chronic neck pain
    Broisler, Camila N.
    Gaban, Giovanna L. N. A.
    Vivaldini, Maria R. S.
    Nunes, Giovanna S.
    Selistre, Luiz F. A.
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2025, 76