Data Acquisition and Intraoperative Tissue Analysis on a Mobile, Battery-Operated, Orbitrap Mass Spectrometer

被引:0
|
作者
Keating, Michael F. [1 ,2 ]
Wolfe, Charles A. [2 ]
Liebenberg, Keziah [2 ]
Montgomery, Ashley [2 ]
Porcari, Andreia M. [2 ,3 ]
Fleming, Nicole D. [4 ]
Makarov, Alexander [5 ]
Eberlin, Livia S. [2 ]
机构
[1] Univ Texas Austin, Dept Chem, Austin, TX 78712 USA
[2] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
[3] Univ Sa~o Francisco, Hlth Sci Postgrad Program, Lab Mass Spectrometry MS4Life, BR-12916900 Braganca Paulista, SP, Brazil
[4] Univ Texas MD Anderson Canc Ctr, Dept Surg, Houston, TX 77030 USA
[5] Thermo Fisher Sci, D-28199 Bremen, Germany
基金
美国国家卫生研究院;
关键词
RAPID ANALYSIS;
D O I
10.1021/acs.analchem.4c00722
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mass spectrometry has been increasingly explored in intraoperative studies as a potential technology to help guide surgical decision making. Yet, intraoperative experiments using high-performance mass spectrometry instrumentation present a unique set of operational challenges. For example, standard operating rooms are often not equipped with the electrical requirements to power a commercial mass spectrometer and are not designed to accommodate their permanent installation. These obstacles can impact progress and patient enrollment in intraoperative clinical studies because implementation of MS instrumentation becomes limited to specific operating rooms that have the required electrical connections and space. To expand our intraoperative clinical studies using the MasSpec Pen technology, we explored the feasibility of transporting and acquiring data on Orbitrap mass spectrometers operating on battery power in hospital buildings. We evaluated the effect of instrument movement including acceleration and rotational speeds on signal stability and mass accuracy by acquiring data using direct infusion electrospray ionization. Data were acquired while rolling the systems in/out of operating rooms and while descending/ascending a freight elevator. Despite these movements and operating the instrument on battery power, the relative standard deviation of the total ion current was <5% and the magnitude of the mass error relative to the internal calibrant never exceeded 5.06 ppm. We further evaluated the feasibility of performing intraoperative MasSpec Pen analysis while operating the Orbitrap mass spectrometer on battery power during an ovarian cancer surgery. We observed that the rich and tissue-specific molecular profile commonly detected from ovarian tissues was conserved when running on battery power. Together, these results demonstrate that Orbitrap mass spectrometers can be operated and acquire data on battery power while in motion and in rotation without losses in signal stability or mass accuracy. Furthermore, Orbitrap mass spectrometers can be used in conjunction to the MasSpec Pen while on battery power for intraoperative tissue analysis.
引用
下载
收藏
页码:8234 / 8242
页数:9
相关论文
共 50 条
  • [1] A BATTERY-OPERATED DATA-ACQUISITION SYSTEM
    WILLIAMS, RM
    HAUMANN, JR
    WHITE, RV
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (02) : 356 - 360
  • [2] Wireless, battery-operated data acquisition system for mobile spectrometry applications and (potentially) for the internet of things
    Fitzgerald, Ryan
    Karanassios, Vassili
    NEXT-GENERATION SPECTROSCOPIC TECHNOLOGIES X, 2017, 10210
  • [3] FREDDY BATTERY-OPERATED MOBILE SUMP CLEANER AND FILTER
    不详
    MACHINERY, 1972, 120 (3101): : 539 - &
  • [4] Progress and characterization of battery-operated microplasmas by a portable optical emission spectrometer
    Quadeer, Laiba
    Zhou, Vera
    Karanassios, Vassili
    APPLIED OPTICAL METROLOGY IV, 2021, 11817
  • [5] Quantitative-Qualitative Data Acquisition Using a Benchtop Orbitrap Mass Spectrometer
    Bateman, Kevin P.
    Kellmann, Markus
    Muenster, Helmut
    Papp, Robert
    Taylor, Lester
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (08) : 1441 - 1450
  • [6] Design and Implementation of an Orbitrap Mass Spectrometer Data Acquisition System for Atmospheric Molecule Identification
    Wang, Wei
    Li, Yongping
    ELECTRONICS, 2023, 12 (11)
  • [7] Analysis of the Operating Life for Battery-Operated Wireless Sensor Nodes
    Antolin, D.
    Medrano, N.
    Calvo, B.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 3883 - 3886
  • [8] Feasibility Study on Power Buffer for Supplying Transient Power to Battery-Operated Mobile Systems
    Bui Thien Vuong
    Noh, Myounggyu
    Park, Young-Woo
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2021, 45 (06) : 473 - 479
  • [9] Factorial Experimental Designs Elucidate Significant Variables Affecting Data Acquisition on a Quadrupole Orbitrap Mass Spectrometer
    Randall, Shan M.
    Cardasis, Helene L.
    Muddiman, David C.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (10) : 1501 - 1512
  • [10] Use of a Battery-Operated Needle Driver for Intraosseous Access by Novice Users: Skill Acquisition With Cadavers
    Levitan, Richard M.
    Bortle, Charles D.
    Snyder, Thomas A.
    Nitsch, David A.
    Pisaturo, James T.
    Butler, Kenneth H.
    ANNALS OF EMERGENCY MEDICINE, 2009, 54 (05) : 692 - 694