Review of Detection Limits for Various Techniques for Bacterial Detection in Food Samples

被引:0
|
作者
Zhao, Xinyi [1 ,2 ]
Bhat, Abhijnan [1 ,3 ]
O'Connor, Christine [1 ]
Curtin, James [4 ]
Singh, Baljit [1 ,3 ]
Tian, Furong [1 ,2 ]
机构
[1] Technol Univ Dublin, Sch Food Sci & Environm Hlth, Dublin D07 ADY7, Ireland
[2] Technol Univ Dublin, FOCAS Res Inst, Dublin D08 CKP1, Ireland
[3] Technol Univ Dublin, MiCRA Biodiagnost Technol Gateway & Hlth Engn & Ma, Dublin D24 FKT9, Ireland
[4] Technol Univ Dublin, Fac Engn & Built Environm, Bolton St, Dublin D01 K822, Ireland
关键词
limit of detection (LOD); bacterial detection; LFIA; PCR; electrochemical method; REAL-TIME PCR; LATERAL FLOW IMMUNOASSAY; RESISTANT STAPHYLOCOCCUS-AUREUS; REDUCED GRAPHENE OXIDE; ESCHERICHIA-COLI O157; LABEL-FREE DETECTION; LISTERIA-MONOCYTOGENES; RAPID DETECTION; IMMUNOMAGNETIC SEPARATION; SALMONELLA-TYPHIMURIUM;
D O I
10.3390/nano14100855
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Foodborne illnesses can be infectious and dangerous, and most of them are caused by bacteria. Some common food-related bacteria species exist widely in nature and pose a serious threat to both humans and animals; they can cause poisoning, diseases, disabilities and even death. Rapid, reliable and cost-effective methods for bacterial detection are of paramount importance in food safety and environmental monitoring. Polymerase chain reaction (PCR), lateral flow immunochromatographic assay (LFIA) and electrochemical methods have been widely used in food safety and environmental monitoring. In this paper, the recent developments (2013-2023) covering PCR, LFIA and electrochemical methods for various bacterial species (Salmonella, Listeria, Campylobacter, Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli)), considering different food sample types, analytical performances and the reported limit of detection (LOD), are discussed. It was found that the bacteria species and food sample type contributed significantly to the analytical performance and LOD. Detection via LFIA has a higher average LOD (24 CFU/mL) than detection via electrochemical methods (12 CFU/mL) and PCR (6 CFU/mL). Salmonella and E. coli in the Pseudomonadota domain usually have low LODs. LODs are usually lower for detection in fish and eggs. Gold and iron nanoparticles were the most studied in the reported articles for LFIA, and average LODs were 26 CFU/mL and 12 CFU/mL, respectively. The electrochemical method revealed that the average LOD was highest for cyclic voltammetry (CV) at 18 CFU/mL, followed by electrochemical impedance spectroscopy (EIS) at 12 CFU/mL and differential pulse voltammetry (DPV) at 8 CFU/mL. LOD usually decreases when the sample number increases until it remains unchanged. Exponential relations (R-2 > 0.95) between LODs of Listeria in milk via LFIA and via the electrochemical method with sample numbers have been obtained. Finally, the review discusses challenges and future perspectives (including the role of nanomaterials/advanced materials) to improve analytical performance for bacterial detection.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] An overview of methods/techniques for the detection of Cryptosporidium in food samples
    Ahmed, Shahira A.
    Karanis, Panagiotis
    [J]. PARASITOLOGY RESEARCH, 2018, 117 (03) : 629 - 653
  • [2] An overview of methods/techniques for the detection of Cryptosporidium in food samples
    Shahira A. Ahmed
    Panagiotis Karanis
    [J]. Parasitology Research, 2018, 117 : 629 - 653
  • [3] A Review on: Various Techniques of Plant Leaf Disease Detection
    Singh, Jaskaran
    Kaur, Harpreet
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON INVENTIVE SYSTEMS AND CONTROL (ICISC 2018), 2018, : 232 - 238
  • [4] A Review on Various Techniques of Brain Tumor Boundary Detection
    Dharnia, Sunita
    Wasson, Vikas
    [J]. PROCEEDINGS OF THE 2019 6TH INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT (INDIACOM), 2019, : 713 - 718
  • [5] Systematic Review on Various Techniques of Android Malware Detection
    Dave, Dharmesh D.
    Rathod, Digvijaysinh
    [J]. COMPUTING SCIENCE, COMMUNICATION AND SECURITY, 2022, 1604 : 82 - 99
  • [6] Noninvasive techniques for detection of foreign bodies in food: A review
    Khairi, Mohd Taufiq Mohd
    Ibrahim, Sallehuddin
    Yunus, Mohd Amri Md
    Faramarzi, Mahdi
    [J]. JOURNAL OF FOOD PROCESS ENGINEERING, 2018, 41 (06)
  • [7] The need for detection of the total amount of various antioxidants in food samples.
    Sterner, A
    Wallace, S
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U80 - U80
  • [8] A comprehensive review on the detection of Staphylococcus aureus enterotoxins in food samples
    Li, Qing
    Dou, Leina
    Zhang, Yingjie
    Luo, Liang
    Yang, Huijuan
    Wen, Kai
    Yu, Xuezhi
    Shen, Jianzhong
    Wang, Zhanhui
    [J]. COMPREHENSIVE REVIEWS IN FOOD SCIENCE AND FOOD SAFETY, 2024, 23 (01) : 1 - 45
  • [9] Electrochemical sensors for improved detection of paraquat in food samples: A review
    Laghrib, F.
    Bakasse, M.
    Lahrich, S.
    El Mhammedi, M. A.
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 107
  • [10] Review of the various analytical techniques and algorithms for detection and quantification of TATP
    Pacheco-Londoño, L
    Primera, OM
    Ramírez, M
    Ruiz, O
    Hernandez-Rivera, S
    [J]. SENSORS, AND COMMAND, CONTROL, COMMUNICATIONS, AND INTELLIGENCE (C31) TECHNOLOGIES FOR HOMELAND SECURITY AND HOMELAND DEFENSE IV, PTS 1 AND 2, 2005, 5778 : 317 - 326