Performance Assessment of Two Low-Cost PM2.5 and PM10 Monitoring Networks in the Padana Plain (Italy)

被引:1
|
作者
Gualtieri, Giovanni [1 ]
Brilli, Lorenzo [1 ]
Carotenuto, Federico [1 ]
Cavaliere, Alice [2 ]
Giordano, Tommaso [1 ]
Putzolu, Simone [1 ]
Vagnoli, Carolina [1 ]
Zaldei, Alessandro [1 ]
Gioli, Beniamino [1 ]
机构
[1] CNR, Inst Bioecomony CNR IBE, Via Caproni 8, I-50145 Florence, Italy
[2] CNR, Inst Polar Sci CNR ISP, Via P Gobetti 101, I-40129 Bologna, Italy
关键词
air quality; low-cost sensor; PM2.5; PM10; PurpleAir; AirQino; Padana Plain; PURPLEAIR; SENSORS; VALLEY;
D O I
10.3390/s24123946
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two low-cost (LC) monitoring networks, PurpleAir (instrumented by Plantower PMS5003 sensors) and AirQino (Novasense SDS011), were assessed in monitoring PM2.5 and PM10 daily concentrations in the Padana Plain (Northern Italy). A total of 19 LC stations for PM2.5 and 20 for PM10 concentrations were compared vs. regulatory-grade stations during a full "heating season" (15 October 2022-15 April 2023). Both LC sensor networks showed higher accuracy in fitting the magnitude of PM10 than PM2.5 reference observations, while lower accuracy was shown in terms of RMSE, MAE and R-2. AirQino stations under-estimated both PM2.5 and PM10 reference concentrations (MB = -4.8 and -2.9 mu g/m(3), respectively), while PurpleAir stations over-estimated PM2.5 concentrations (MB = +5.4 mu g/m(3)) and slightly under-estimated PM10 concentrations (MB = -0.4 mu g/m(3)). PurpleAir stations were finer than AirQino at capturing the time variation of both PM2.5 and PM10 daily concentrations (R-2 = 0.68-0.75 vs. 0.59-0.61). LC sensors from both monitoring networks failed to capture the magnitude and dynamics of the PM2.5/PM10 ratio, confirming their well-known issues in correctly discriminating the size of individual particles. These findings suggest the need for further efforts in the implementation of mass conversion algorithms within LC units to improve the tuning of PM2.5 vs. PM10 outputs.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Performance of low-cost indoor air quality monitors for PM2.5 and PM10 from residential sources
    Wang, Zhiqiang
    Delp, William W.
    Singer, Brett C.
    [J]. BUILDING AND ENVIRONMENT, 2020, 171
  • [2] Development of Low-Cost Air Quality Stations for Next Generation Monitoring Networks: Calibration and Validation of PM2.5 and PM10 Sensors
    Cavaliere, Alice
    Carotenuto, Federico
    Di Gennaro, Filippo
    Gioli, Beniamino
    Gualtieri, Giovanni
    Martelli, Francesca
    Matese, Alessandro
    Toscano, Piero
    Vagnoli, Carolina
    Zaldei, Alessandro
    [J]. SENSORS, 2018, 18 (09)
  • [3] Comparison of three prediction strategies within PM2.5 and PM10 monitoring networks
    He, Hong-di
    Lu, Wei-zhen
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2020, 11 (03) : 590 - 597
  • [4] Sidestream cigarette smoke:: a low cost monitoring system to evaluate PM10 and PM2.5 emission factors
    Kura, B
    Weatherton, Y
    Naoum, E
    Kambham, K
    Sangameswaran, S
    [J]. Air Pollution XIII, 2005, 82 : 417 - 424
  • [5] Particulate matter in California:: Part 1 -: Intercomparison of several PM2.5, PM10-2.5, and PM10 monitoring networks
    Motallebi, N
    Taylor, CA
    Turkiewicz, K
    Croes, BE
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2003, 53 (12): : 1509 - 1516
  • [6] Evaluation of Low-Cost Sensors for Ambient PM2.5 Monitoring
    Badura, Marek
    Batog, Piotr
    Drzeniecka-Osiadacz, Anetta
    Modzel, Piotr
    [J]. JOURNAL OF SENSORS, 2018, 2018
  • [7] Comparison of PM2.5 and PM10 monitors
    Williams, R
    Suggs, J
    Rodes, C
    Lawless, P
    Zweidinger, R
    Kwok, R
    Creason, J
    Sheldon, L
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (05): : 497 - 505
  • [8] Comparison of PM2.5 and PM10 monitors
    RON WILLIAMS
    JACK SUGGS
    CHARLES RODES
    PHIL LAWLESS
    ROY ZWEIDINGER
    RICHARD KWOK
    JOHN CREASON
    LINDA SHELDON
    [J]. Journal of Exposure Science & Environmental Epidemiology, 2000, 10 : 497 - 505
  • [9] PM10 and PM2.5:: an international perspective
    Sloss, LL
    Smith, IM
    [J]. FUEL PROCESSING TECHNOLOGY, 2000, 65 : 127 - 141
  • [10] Monitoring trace elements by nuclear techniques in PM10 and PM2.5
    Freitas, MC
    Almeida, SM
    Reis, MA
    Oliveira, OR
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 430 - 434