Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant

被引:0
|
作者
Chebil, Sabrine [1 ]
Ruiz-Garcia, A. [2 ]
Farhat, Soumaya [1 ]
Bali, Mahmoud [1 ]
机构
[1] Univ Gabes, Higher Inst Water Sci & Tech, Gabes 6072, Tunisia
[2] Univ Las Palmas Gran Canaria, Dept Elect Engn & Automat, Campus Univ Tafira, E-35017 Las Palmas Gran Canaria, Spain
关键词
brackish water; desalination; reverse osmosis; fouling; standardization; permeability; RO MEMBRANE; SEAWATER DESALINATION; GROUNDWATER TREATMENT; MASS-TRANSFER; GYPSUM; OPERATION; AUTOPSY; NANOFILTRATION; OPTIMIZATION; PRETREATMENT;
D O I
10.3390/w16131892
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water scarcity in Tunisia's semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L-1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42- and Cl- ions increased, with Cl- showing an 88% increase and SO42- showing an 87% increase. The produced water's salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Structural and chemical characterization of long-term reverse osmosis membrane fouling in a full scale desalination plant
    Melian-Martel, N.
    Sadhwani, J. J.
    Malamis, S.
    Ochsenkuehn-Petropoulou, M.
    [J]. DESALINATION, 2012, 305 : 44 - 53
  • [2] Enhanced exergy analysis of a full-scale brackish water reverse osmosis desalination plant
    Fellaou, S.
    Ruiz-Garcia, A.
    Gourich, B.
    [J]. DESALINATION, 2021, 506 (506)
  • [3] Evaluation of thin film nanocomposite reverse osmosis membranes for long-term brackish water desalination performance
    Cay-Durgun, Pinar
    McCloskey, Cailen
    Konecny, John
    Khosravi, Afsaneh
    Lind, Mary Laura
    [J]. DESALINATION, 2017, 404 : 304 - 312
  • [4] Analysis of long-term performance of full-scale reverse osmosis desalination plant using artificial neural network and tree model
    Choi, Yongjun
    Lee, Younggeun
    Shin, Kwanghee
    Park, Youngkyu
    Lee, Sangho
    [J]. ENVIRONMENTAL ENGINEERING RESEARCH, 2020, 25 (05) : 763 - 770
  • [5] Performance Analysis of a Full-Scale Desalination Plant with Reverse Osmosis Membranes for Irrigation
    Leon, Federico
    Ramos, Alejandro
    [J]. MEMBRANES, 2021, 11 (10)
  • [6] Full-Scale Seawater Reverse Osmosis Desalination Plant Simulator
    Elnour, Mariam
    Meskin, Nader
    Khan, Khlaed M.
    Jain, Raj
    Zaidi, Syed
    Siddiqui, Hammadur
    [J]. IFAC PAPERSONLINE, 2020, 53 (02): : 16561 - 16568
  • [7] Long-term performance decline in a brackish water reverse osmosis desalination plant. Predictive model for the water permeability coefficient
    Ruiz-Garcia, A.
    Nuez, I.
    [J]. DESALINATION, 2016, 397 : 101 - 107
  • [8] Retrofitting assessment of a full-scale brackish water reverse osmosis desalination plant with a feed capacity of 600 m3/d
    Ruiz-Garcia, A.
    Dimitriou, E.
    Nuez, I.
    [J]. DESALINATION AND WATER TREATMENT, 2019, 144 : 72 - 78
  • [9] Performance Evaluation of Reverse Osmosis Brackish Water Desalination Plant with Different Recycled Ratios of Retentate
    Alsarayreh, A. A.
    Al-Obaidi, M. A.
    Al-Liroub, A. M.
    Patel, R.
    Mujtaba, I. M.
    [J]. 29TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PT A, 2019, 46 : 181 - 186
  • [10] Performance evaluation of reverse osmosis brackish water desalination plant with different recycled ratios of retentate
    Alsarayreh, Alanood A.
    Al-Obaidi, M. A.
    Al-Hroub, A. M.
    Patel, R.
    Mujtaba, I. M.
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2020, 135