The axial tensile performance of DSCW-RC joints with lap-spliced bars

被引:0
|
作者
Wang, Ying [1 ]
Wei, Jinrui [1 ]
Zuo, Junbo [1 ]
Fang, Chenxi [1 ]
Lai, Zhichao [1 ]
Guan, Minsheng [2 ]
Yu, Changbin [3 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 518060, Peoples R China
[2] Shenzhen Univ, Key Lab Coastal Urban Resilient Infrastructures MO, Shenzhen 518060, Peoples R China
[3] China Railway 18th Bur Grp Corp Ltd, Tianjin 300222, Peoples R China
基金
中国国家自然科学基金;
关键词
Lap -spliced connection; Axial tension test; Force transmission mechanism; COMPOSITE SC WALLS; SHEAR BEHAVIOR; CONCRETE; STRENGTH; DESIGN;
D O I
10.1016/j.istruc.2024.106205
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Joints formed between double-skin concrete shear walls (DSCWs) and reinforced concrete (RC) foundations commonly utilize lap-spliced bars to transfer forces. However, the behavior and design of these critical connections have not been thoroughly investigated. This study experimentally analyzes a steel-reinforced DSCW-toRC foundation anchorage joint under monotonic uniaxial tension loading. Seven 1:3 scale specimens were tested to examine the effects of varying lap-spliced bar diameter, steel plate thickness, and stud bolt spacing. Crack propagation, load-displacement response, and reinforcement strain were measured. The results characterize two potential failure modes: ductile steel yielding and brittle stud shearing. Steel strains developed linearly up to yielding, demonstrating uniform transmission of tensile loads. Increased plate thickness and decreased stud spacing enhanced capacity. To mitigate sudden shear failures, the number and strength of studs must exceed the expected tensile demand. New design recommendations are proposed, including minimum stud bolt shear strength and the use of confining tie bars. This study provides an improved understanding of the behavior of DSCW-to-RC foundation lap-spliced connections, enabling resistance to axial demands while avoiding brittle failure modes. The experimental data will inform future analytical models and design provisions for these critical structural joints.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] The shear performance of DSCW-RC joints with lap-spliced steel bars
    Wei, Jinrui
    Wang, Ying
    Wu, Youdong
    Huang, Yong
    Yang, Yuxing
    [J]. Structures, 2024, 69
  • [2] Seismic performance investigation of RC piers with lap-spliced longitudinal bars as to aspect ratio
    Cho, Chang Beck
    Kim, Gwang Mok
    Kwahk, Im Jong
    Chung, Young Soo
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2014, 18 (06) : 1768 - 1779
  • [3] Seismic performance investigation of RC piers with lap-spliced longitudinal bars as to aspect ratio
    Chang Beck Cho
    Gwang Mok Kim
    Im Jong Kwahk
    Young Soo Chung
    [J]. KSCE Journal of Civil Engineering, 2014, 18 : 1768 - 1779
  • [4] Bond strength of lap-spliced bars
    Canbay, E
    Frosch, RJ
    [J]. ACI STRUCTURAL JOURNAL, 2005, 102 (04) : 605 - 614
  • [5] Design of lap-spliced bars: Is simplification possible?
    Department of Civil Engineering, Middle East Technical University, Ankara, Turkey
    不详
    [J]. ACI Struct J, 2006, 3 (444-451):
  • [6] Behavior of Lap-Spliced Plain Steel Bars
    Hassan, M. Nazmul
    Feldman, Lisa R.
    [J]. ACI STRUCTURAL JOURNAL, 2012, 109 (02) : 235 - 243
  • [7] Design of lap-spliced bars: Is simplification possible?
    Canbay, E
    Frosch, RJ
    [J]. ACI STRUCTURAL JOURNAL, 2006, 103 (03) : 444 - 451
  • [8] Seismic retrofitting of damaged RC columns with lap-spliced bars using FRP sheets
    Anagnostou, Evgenia
    Rousakis, Theodoros C.
    Karabinis, Athanasios I.
    [J]. COMPOSITES PART B-ENGINEERING, 2019, 166 : 598 - 612
  • [9] Behavior of Lap-Spliced Plain Steel Bars Discussion
    Prince, M. John Robert
    Singh, Bhupinder
    [J]. ACI STRUCTURAL JOURNAL, 2013, 110 (01) : 157 - 157
  • [10] Stress along tensile lap-spliced fibre reinforced polymer reinforcing bars in concrete
    Aly, Ragi
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 2007, 34 (09) : 1149 - 1158