Safety and feasibility of atrial fibrillation ablation after left atrial appendage closure: A single-center experience of the left atrial appendage closure first strategy

被引:1
|
作者
Chatani, Ryuki [1 ]
Kubo, Shunsuke [1 ]
Tasaka, Hiroshi [1 ]
Sakata, Atsushi [1 ]
Yoshino, Mitsuru [1 ]
Maruo, Takeshi [1 ]
Kadota, Kazushige [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiovasc Med, 1-1-1 Miwa, Kurashiki, Okayama 7108602, Japan
关键词
antithrombotic regimen; atrial fibrillation; catheter ablation; left atrial appendage closure; peri-device leak; EXPERT CONSENSUS STATEMENT; CATHETER ABLATION; OCCLUSION; PREVENTION; WATCHMAN; WARFARIN; STROKE;
D O I
10.1002/joa3.13073
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients with atrial fibrillation (AF) who are not suitable for long-term anticoagulant therapy undergo percutaneous left atrial appendage closure (LAAC). The safety and feasibility of left atrial catheter ablation (CA) procedures after LAAC remain unclear. This study aimed to clarify the feasibility and safety of CA after LAAC, including in the early phase within 180 days. Methods: Characteristics and clinical outcomes of 46 patients with AF who had undergone both CA and LAAC within 2 years (mean age, 72 years; 29 men) were compared between those who had undergone CA-first (31 patients) and LAAC-first (15 patients). Results: The mean CHA(2)DS(2)-VASc and HAS-BLED scores were 4.8 and 3.3 points, respectively. The LAAC-first strategy was often used in patients with prior major bleeding and LAA thrombosis or sludge. In the LAAC-first group, the mean duration between both procedures was 212 days, and all LAAC-first patients, including seven patients in the early phase, could undergo CA without LAAC device-related complications; moreover, no cardiovascular adverse events were reported after both procedures (mean periods: 420 days). After CA post-LAAC, no device-related adverse events (device-related thrombosis, new peri-device leak appearance, peri-device leak increase, or device dislodgement) were observed, whereas, after LAAC post-CA, 3 new peri-device leak appearance events and 1 peri-device leak increase event were observed, especially patients who underwent LAAC in the early phase post-CA. Conclusion: Based on single-center experience, left atrial CA in the presence of an LAAC device implanted including the early phase was safe and feasible.
引用
收藏
页码:879 / 890
页数:12
相关论文
共 50 条
  • [1] Editorial to "Safety and feasibility of atrial fibrillation ablation after left atrial appendage closure: A single-center experience of the left atrial appendage closure-first strategy"
    Kondo, Yusuke
    Ryuzaki, Satoko
    Kobayashi, Yoshio
    JOURNAL OF ARRHYTHMIA, 2024, 40 (04) : 891 - 892
  • [2] Left Atrial Appendage Closure in Atrial Fibrillation
    Fauchier, Laurent
    Cinaud, Alexandre
    Brigadeau, Francois
    Lepillier, Antoine
    Pierre, Bertrand
    Gras, Daniel
    Mansourati, Jacques
    Deharo, Jean Claude
    Montalescot, Gilles
    Defaye, Pascal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) : 2806 - 2807
  • [3] Ablation for Atrial Fibrillation in Combination With Left Atrial Appendage Closure: First Results of a Feasibility Study
    Swaans, Martin J.
    Post, Martijn C.
    Rensing, Benno J. W. M.
    Boersma, Lucas V. A.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2012, 1 (05): : e002212
  • [4] Left atrial appendage closure after cryoballoon ablation in patients with atrial fibrillation
    Liu, Jun
    Xia, Yu
    Zhang, Hao
    Li, Xiaofeng
    Zhang, Shu
    Fang, Pihua
    HERZ, 2021, 46 (SUPPL 1) : 82 - 88
  • [5] Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
    Swaans, Martin J.
    Alipour, Arash
    Rensing, Benno J. W. M.
    Post, Martijn C.
    Boersma, Lucas V. A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (72):
  • [6] Safety and feasibility of combined atrial fibrillation ablation and left atrial appendage occlusion after left atrial appendage electrical isolation
    Kenneth Kita
    Steven Carlson
    Mary Huntsinger
    Han Tun
    Jina Sohn
    Rahul N. Doshi
    Journal of Interventional Cardiac Electrophysiology, 2020, 57 : 43 - 55
  • [7] Left Atrial Appendage Closure for Atrial Fibrillation Reply
    Reddy, Vivek Y.
    Holmes, David
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 313 (10): : 1057 - 1058
  • [8] Safety and feasibility of combined atrial fibrillation ablation and left atrial appendage occlusion after left atrial appendage electrical isolation
    Kita, Kenneth
    Carlson, Steven
    Huntsinger, Mary
    Tun, Han
    Sohn, Jina
    Doshi, Rahul N.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (01) : 43 - 55
  • [9] Left Atrial Appendage Closure Device in Atrial Fibrillation
    Giudici, Michael C.
    Bhave, Prashant D.
    CARDIOLOGY CLINICS, 2017, 35 (02) : 297 - +
  • [10] Safety of Amulet Left Atrial Appendage Occluder and Watchman Device for Left Atrial Appendage Closure in Patients With Atrial Fibrillation
    Sawaya, Fadi
    Abi-Saleh, Bernard
    Hoteit, Abbas
    Jdaidany, Jennifer
    Moumneh, Mohamad B.
    Harbieh, Bernard
    Khoury, Maurice
    Aramouni, Salim
    Abdulhai, Farah
    Refaat, Marwan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)