fs-laser preparation of half grid specimens for atom probe tomography and transmission electron microscopy

被引:5
|
作者
Tkadletz, Michael [1 ]
Schiester, Maximilian [2 ]
Waldl, Helene [3 ]
Schusser, Georg [4 ]
Krause, Michael [5 ]
Schalk, Nina [1 ,3 ]
机构
[1] Univ Leoben, Dept Mat Sci, Franz Josef Str 18, A-8700 Leoben, Austria
[2] Mat Ctr Leoben Forsch GmbH, Roseggerstr 12, A-8700 Leoben, Austria
[3] Univ Leoben, Christian Doppler Lab Adv Coated Cutting Tools, Franz Josef Str 18, A-8700 Leoben, Austria
[4] Fraunhofer Inst Microstruct Mat & Syst IMWS, Walter Hulse Str 1, D-06120 Halle, Germany
[5] Univ Appl Sci Merseburg, Eberhard Leibnitz Str 2, D-06217 Merseburg, Germany
来源
关键词
APT; TEM; Lift-out; Femtosecond laser ablation; Coatings;
D O I
10.1016/j.mtcomm.2024.108672
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For atom probe tomography (APT) and transmission electron microscopy (TEM) half grids are commonly applied as specimen carriers, serving as mount for focused ion beam (FIB) processed lift-outs. This technical note presents an alternative way to fabricate half grids directly from the material to be investigated using femtosecond (fs)-laser ablation. After cutting similar to 200 mu m thin in-plane and cross-plane slices from a TiN coated cemented carbide substrate using a precision cutting saw, two different half grid geometries, one suitable for APT and the other for TEM, were cut via fs-laser processing. Freestanding posts for APT were further sharpened and the areas intended for TEM were thinned top-down using the fs-laser system followed by final annular FIB milling of the APT and thinning of the TEM specimens. For proof of concept, the TiN APT half grid specimens in in- and cross-plane direction were successfully measured in voltage and laser-assisted mode, utilizing a local electrode atom probe, while electron transparency of the in- and cross-plane TEM half grid specimens was proven using a scanning electron microscope equipped with a scanning transmission electron microscopy (STEM) detector. The herein presented method is simple, fast and omits the necessity of a lift-out, reducing the complexity of FIB operations. Additionally, a frequently considered weak point of APT lift-out specimens, the Pt weld between specimen and half grid or microtip coupon is avoided, whilst a wide range of materials can be processed and consumables consumption is reduced. Thus, this work clearly demonstrates the great potential of fs-laser processing for APT and TEM specimen preparation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Laser ablation sample preparation for atom probe tomography and transmission electron microscopy
    White, N.
    Eder, K.
    Byrnes, J.
    Cairney, J. M.
    McCarroll, I. E.
    ULTRAMICROSCOPY, 2021, 220
  • [2] Efficient preparation of microtip arrays for atom probe tomography using fs-laser processing
    Tkadletz, Michael
    Waldl, Helene
    Schiester, Maximilian
    Lechner, Alexandra
    Schusser, Georg
    Krause, Michael
    Schalk, Nina
    ULTRAMICROSCOPY, 2023, 246
  • [3] Specimen preparation for correlating transmission electron microscopy and atom probe tomography of mesoscale features
    Hartshorne, Matthew I.
    Isheim, Dieter
    Seidman, David N.
    Taheri, Mitra L.
    ULTRAMICROSCOPY, 2014, 147 : 25 - 32
  • [4] Preparation of nanowire specimens for laser-assisted atom probe tomography
    Blumtritt, H.
    Isheim, D.
    Senz, S.
    Seidman, D. N.
    Moutanabbir, O.
    NANOTECHNOLOGY, 2014, 25 (43)
  • [5] On spinodal decomposition in alnico - A transmission electron microscopy and atom probe tomography study
    Zhou, Lin
    Guo, Wei
    Poplawsky, J. D.
    Ke, Liqin
    Tang, Wei
    Anderson, I. E.
    Kramer, M. J.
    ACTA MATERIALIA, 2018, 153 : 15 - 22
  • [6] Grain Boundary Plane Measurement Using Transmission Electron Microscopy Automated Crystallographic Orientation Mapping for Atom Probe Tomography Specimens
    Hartshorne, Matthew
    Leff, Asher
    Vetterick, Gregory
    Hopkins, Emily M.
    Taheri, Mitra L.
    MICROSCOPY AND MICROANALYSIS, 2023, 29 (03) : 1018 - 1025
  • [7] PREPARATION OF GAAS SPECIMENS FOR TRANSMISSION ELECTRON MICROSCOPY
    BIEDERMANN, E
    BRACK, K
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1966, 113 (10) : 1088 - +
  • [8] Atom probe tomography and transmission electron microscopy investigation of chromium nitrides in FeCr alloys
    Danoix, Raphaeele
    Legras, Laurent
    Hannoyer, Beatrice
    Dulcy, Jacky
    Danoix, Frederic
    SOLID-SOLID PHASE TRANSFORMATIONS IN INORGANIC MATERIALS 2005, VOL 1, 2005, : 351 - 356
  • [9] Quantitative comparison of energy-filtering transmission electron microscopy and atom probe tomography
    Stender, Patrick
    Heil, Tobias
    Kohl, Helmut
    Schmitz, Guido
    ULTRAMICROSCOPY, 2009, 109 (05) : 612 - 618
  • [10] Time resolved EUV pump-probe microscopy of fs-LASER induced nanostructure formation
    Freiberger, R.
    Hauck, J.
    Reininghaus, M.
    Wortmann, D.
    Juschkin, L.
    EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE II, 2011, 8076