fs-laser preparation of half grid specimens for atom probe tomography and transmission electron microscopy

被引:1
|
作者
Tkadletz, Michael [1 ]
Schiester, Maximilian [2 ]
Waldl, Helene [3 ]
Schusser, Georg [4 ]
Krause, Michael [5 ]
Schalk, Nina [1 ,3 ]
机构
[1] Univ Leoben, Dept Mat Sci, Franz Josef Str 18, A-8700 Leoben, Austria
[2] Mat Ctr Leoben Forsch GmbH, Roseggerstr 12, A-8700 Leoben, Austria
[3] Univ Leoben, Christian Doppler Lab Adv Coated Cutting Tools, Franz Josef Str 18, A-8700 Leoben, Austria
[4] Fraunhofer Inst Microstruct Mat & Syst IMWS, Walter Hulse Str 1, D-06120 Halle, Germany
[5] Univ Appl Sci Merseburg, Eberhard Leibnitz Str 2, D-06217 Merseburg, Germany
来源
关键词
APT; TEM; Lift-out; Femtosecond laser ablation; Coatings;
D O I
10.1016/j.mtcomm.2024.108672
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For atom probe tomography (APT) and transmission electron microscopy (TEM) half grids are commonly applied as specimen carriers, serving as mount for focused ion beam (FIB) processed lift-outs. This technical note presents an alternative way to fabricate half grids directly from the material to be investigated using femtosecond (fs)-laser ablation. After cutting similar to 200 mu m thin in-plane and cross-plane slices from a TiN coated cemented carbide substrate using a precision cutting saw, two different half grid geometries, one suitable for APT and the other for TEM, were cut via fs-laser processing. Freestanding posts for APT were further sharpened and the areas intended for TEM were thinned top-down using the fs-laser system followed by final annular FIB milling of the APT and thinning of the TEM specimens. For proof of concept, the TiN APT half grid specimens in in- and cross-plane direction were successfully measured in voltage and laser-assisted mode, utilizing a local electrode atom probe, while electron transparency of the in- and cross-plane TEM half grid specimens was proven using a scanning electron microscope equipped with a scanning transmission electron microscopy (STEM) detector. The herein presented method is simple, fast and omits the necessity of a lift-out, reducing the complexity of FIB operations. Additionally, a frequently considered weak point of APT lift-out specimens, the Pt weld between specimen and half grid or microtip coupon is avoided, whilst a wide range of materials can be processed and consumables consumption is reduced. Thus, this work clearly demonstrates the great potential of fs-laser processing for APT and TEM specimen preparation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Laser ablation sample preparation for atom probe tomography and transmission electron microscopy
    White, N.
    Eder, K.
    Byrnes, J.
    Cairney, J. M.
    McCarroll, I. E.
    [J]. ULTRAMICROSCOPY, 2021, 220
  • [2] Efficient preparation of microtip arrays for atom probe tomography using fs-laser processing
    Tkadletz, Michael
    Waldl, Helene
    Schiester, Maximilian
    Lechner, Alexandra
    Schusser, Georg
    Krause, Michael
    Schalk, Nina
    [J]. ULTRAMICROSCOPY, 2023, 246
  • [3] Specimen preparation for correlating transmission electron microscopy and atom probe tomography of mesoscale features
    Hartshorne, Matthew I.
    Isheim, Dieter
    Seidman, David N.
    Taheri, Mitra L.
    [J]. ULTRAMICROSCOPY, 2014, 147 : 25 - 32
  • [4] Preparation of nanowire specimens for laser-assisted atom probe tomography
    Blumtritt, H.
    Isheim, D.
    Senz, S.
    Seidman, D. N.
    Moutanabbir, O.
    [J]. NANOTECHNOLOGY, 2014, 25 (43)
  • [5] On spinodal decomposition in alnico - A transmission electron microscopy and atom probe tomography study
    Zhou, Lin
    Guo, Wei
    Poplawsky, J. D.
    Ke, Liqin
    Tang, Wei
    Anderson, I. E.
    Kramer, M. J.
    [J]. ACTA MATERIALIA, 2018, 153 : 15 - 22
  • [6] Grain Boundary Plane Measurement Using Transmission Electron Microscopy Automated Crystallographic Orientation Mapping for Atom Probe Tomography Specimens
    Hartshorne, Matthew
    Leff, Asher
    Vetterick, Gregory
    Hopkins, Emily M.
    Taheri, Mitra L.
    [J]. MICROSCOPY AND MICROANALYSIS, 2023, 29 (03) : 1018 - 1025
  • [7] PREPARATION OF GAAS SPECIMENS FOR TRANSMISSION ELECTRON MICROSCOPY
    BIEDERMANN, E
    BRACK, K
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1966, 113 (10) : 1088 - +
  • [8] Atom probe tomography and transmission electron microscopy investigation of chromium nitrides in FeCr alloys
    Danoix, Raphaeele
    Legras, Laurent
    Hannoyer, Beatrice
    Dulcy, Jacky
    Danoix, Frederic
    [J]. SOLID-SOLID PHASE TRANSFORMATIONS IN INORGANIC MATERIALS 2005, VOL 1, 2005, : 351 - 356
  • [9] Quantitative comparison of energy-filtering transmission electron microscopy and atom probe tomography
    Stender, Patrick
    Heil, Tobias
    Kohl, Helmut
    Schmitz, Guido
    [J]. ULTRAMICROSCOPY, 2009, 109 (05) : 612 - 618
  • [10] Time resolved EUV pump-probe microscopy of fs-LASER induced nanostructure formation
    Freiberger, R.
    Hauck, J.
    Reininghaus, M.
    Wortmann, D.
    Juschkin, L.
    [J]. EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE II, 2011, 8076