Taylor dispersion analysis for measurement of diffusivity and size of gadolinium-based contrast agents

被引:2
|
作者
Somnin, Chutintorn [1 ]
Leclercq, Laurent [1 ]
Chamieh, Joseph [1 ]
Le Menedeu, Mael [2 ,3 ]
Medina, Christelle [2 ]
Rousseaux, Olivier [2 ]
Tripier, Raphael [3 ]
Iglesias, Carlos Platas [4 ,5 ]
Corret, Herve [1 ]
机构
[1] Univ Montpellier, CNRS, IBMM, ENSCM, Montpellier, France
[2] CDG, GUERBET Res &Innovat, BP57400, F-95943 Roissy, France
[3] Univ Brest, UMR CNRS CEMCA 6521, F-29238 Brest, France
[4] Univ A Coruna, Facultaded Ciencias, La Coruna 15008, Spain
[5] Univ A Coruna, CICA, La Coruna 15008, Spain
关键词
Taylor dispersion analysis; Diffusion coefficient; Hydrodynamic diameter; Gadolinium-based contrast agents; Magnetic resonance imaging agents; INTRAVENOUS-INJECTION; PHARMACOKINETICS; ELECTROPHORESIS; TOLERABILITY; COEFFICIENT; COMPLEXES; MOLECULES; SOLUTE;
D O I
10.1016/j.ejps.2024.106831
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Gadolinium-based contrast agents (GBCA) are complexes of a Gadolinium metal center and a linear or macrocyclic polyamino-carboxylic acid chelating agent. These agents are employed to enhance the visibility of deep abnormalities through MRI techniques. Knowing the precise dimensions of various GBCA is key parameter for understanding their in-vivo and pharmaco-kinetic behaviors, their diffusivity, as well as their relaxivity. However, conventional size characterization techniques fall short when dealing with these tiny molecules (<= 1 nm). In this work, we propose to determine the size and diffusivity of gadolinium-based contrast agents using Taylor dispersion analysis (TDA). TDA provided a reliable measurement of the hydrodynamic diameter and the diffusion coefficient. The obtained results were compared to DOSY NMR (Diffusion-ordered Nuclear Magnetic Resonance Spectroscopy) and DFT (Density Functional Theory).
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Study of Interactions Between Gadolinium-Based Contrast Agents and Collagen by Taylor Dispersion Analysis and Frontal Analysis Continuous Capillary Electrophoresis
    Somnin, Chutintorn
    Chamieh, Joseph
    Leclercq, Laurent
    Medina, Christelle
    Rousseaux, Olivier
    Cottet, Herve
    PHARMACEUTICALS, 2024, 17 (12)
  • [2] Gadolinium-based Imaging Contrast Agents
    Milic, Natasa
    Preradovic, Nikolina
    Milosevic, Natasa
    Cirilovic, Viktorija Vucaj
    Till, Viktor
    CURRENT MEDICAL IMAGING REVIEWS, 2014, 10 (02) : 140 - 150
  • [3] Gadolinium-based contrast agents and Infertility
    Cildag, Mehmet B.
    ANDROLOGIA, 2018, 50 (09)
  • [4] Extracellular gadolinium-based contrast agents
    Soler-Fernandez, R.
    Mendez-Diaz, C.
    Rodriguez-Garcia, E.
    RADIOLOGIA, 2024, 66 : S51 - S64
  • [5] Alternatives to Gadolinium-Based Contrast Agents
    Tweedle, Michael F.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (01) : 35 - 41
  • [6] Gadolinium-based contrast agents in children
    Michael N. Rozenfeld
    Daniel J. Podberesky
    Pediatric Radiology, 2018, 48 : 1188 - 1196
  • [7] Toxicity of gadolinium-based contrast agents
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 2007, 49 (1262): : 45 - 45
  • [8] Lifecycle of Gadolinium-Based Contrast Agents
    Liu, Michael
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1295 - 1299
  • [9] Gadolinium-based contrast agents and nephrotoxicity
    Morcos, Sameh K.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (05) : 812 - 812
  • [10] Gadolinium-based contrast agents in children
    Rozenfeld, Michael N.
    Podberesky, Daniel J.
    PEDIATRIC RADIOLOGY, 2018, 48 (09) : 1188 - 1196