Reinforcement of a Subcutaneous Pocket for Implantable Cardioverter Defibrillator Insertion Using Acellular Dermal Matrix: A Case Report

被引:0
|
作者
Choi, Jun Ho [1 ]
Lee, Ho Jun [1 ]
Kim, Kwang Seog [1 ]
Park, Hyung Wook [2 ]
Choi, Insu [3 ]
Hwang, Jae Ha [1 ]
Lee, Sam Yong [1 ]
机构
[1] Chonnam Natl Univ, Chonnam Natl Univ Hosp, Med Sch, Dept Plast & Reconstruct Surg, Gwangju 61469, South Korea
[2] Chonnam Natl Univ, Chonnam Natl Univ Hosp, Med Sch, Dept Internal Med,Div Cardiovasc Med, Gwangju 61469, South Korea
[3] Chonnam Natl Univ, Med Sch, Chonnam Natl Univ Hosp, Dept Pediat, Gwangju 61469, South Korea
关键词
acellular dermal matrix; child; defibrillators; implantable; reinforcement; subcutaneous pocket; CHILDREN;
D O I
10.3390/jcm13092614
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pediatric patients who undergo implant insertion into the chest wall face a high risk of implant exposure to the external environment. Five months after an 8-year-old boy underwent implantable cardioverter-defibrillator (ICD) implantation in a subcutaneous pocket in the left anterolateral chest wall to manage long QT syndrome, ICD replacement became necessary owing to exposure risk from distal and lateral thinning of the ICD pocket. Pocket rupture and exposure would increase the risk of infection; therefore, we performed ICD removal and primary pocket closure. Two weeks later, a new suprafascial pocket was created, an acellular dermal matrix (ADM) was attached to the inner wall to prevent ICD protrusion, and a new ICD was inserted. One year postoperatively, the ADM was engrafted, and no complications were observed. A thin subcutaneous layer increases the risk of ICD implantation complications. Inner wall strengthening with an ADM can help prevent pocket rupture.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Pocket infection as a complication of a subcutaneous implantable cardioverter-defibrillator
    Calvagna, Giuseppe Mario
    Ceresa, Fabrizio
    Patane, Salvatore
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (02) : 616 - 618
  • [2] Intermuscular pocket for subcutaneous implantable cardioverter defibrillator: Single-center experience
    Ferrari, Paola
    Giofre, Fabrizio
    De Filippo, Paolo
    JOURNAL OF ARRHYTHMIA, 2016, 32 (03) : 223 - 226
  • [3] Revision of subcutaneous implantable cardioverter defibrillator to intermuscular pocket to prevent inappropriate shocks
    Madjarov, Jeko M.
    Madzharov, Svetozar
    Abedinov, Filip
    Chappuis, Stefanie
    Fedor, John M.
    CLINICAL CASE REPORTS, 2020, 8 (06): : 1081 - 1085
  • [4] Inappropriate Shocks With Subcutaneous Implantable Cardioverter-Defibrillator in a Young Patient: A Case Report
    Khan, Zahid
    Sethumadhavan, Dinesh
    Rayner, Tom
    Kyaw, Sithu
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [5] CASE REPORT: SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR SYSTEM S-ICD
    Scipione, P.
    Luzi, M.
    Bedendi, N.
    Andraghetti, A.
    Capucci, A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S150 - S150
  • [6] First case of subcutaneous implantable cardioverter-defibrillator extrusion
    Santarpia, Giuseppe
    Polimeni, Alberto
    De Rosa, Salvatore
    Sabatino, Jolanda
    Curcio, Antonio
    Indolfi, Ciro
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 192 : 19 - 20
  • [7] Inappropriate Shock Due to Air Entrapment in the Pocket of a Subcutaneous Implantable Cardioverter-defibrillator
    Linhart, Markus
    Maria Tolosana, Jose
    Chipa, Fredy
    Trucco, Emilce
    Mont, Lluis
    REVISTA ESPANOLA DE CARDIOLOGIA, 2019, 72 (01): : 79 - 81
  • [8] A case of pioneering subcutaneous implantable cardioverter defibrillator intervention in Timothy syndrome
    Zhang, Zixi
    Wu, Keke
    Wu, Zhihong
    Xiao, Yunbin
    Wang, Yefeng
    Lin, Qiuzhen
    Wang, Cancan
    Zhu, Qingyi
    Xiao, Yichao
    Liu, Qiming
    BMC PEDIATRICS, 2024, 24 (01)
  • [9] Antithrombotic therapy and the risk of pocket hematoma after subcutaneous implantable cardioverter-defibrillator implantation
    Pepplinkhuizen, S.
    Kors, N.
    De Veld, J. A.
    Dijkshoorn, L. A.
    Bijsterveld, N. R.
    De Weger, A.
    Smeding, L.
    Wilde, A. A. M.
    Nordkamp, L. R. A. Olde
    Knops, R. E.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [10] Antithrombotic therapy and the risk of pocket hematoma after subcutaneous implantable cardioverter-defibrillator implantation
    Pepplinkhuizen, S.
    Kors, N.
    de Veld, J. A.
    Dijkshoorn, L. A.
    Bijsterveld, N. R.
    de Weger, A.
    Smeding, L.
    Wilde, A. A. M.
    Nordkamp, L. R. A. Olde
    Knops, R. E.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2025,