Syndesmotic fixation in Weber B ankle fractures: A systematic review

被引:0
|
作者
Lim, Brandon [1 ]
Shaalan, Mohamed [2 ]
O'hEireamhoin, Sven [2 ]
Lyons, Frank [2 ]
机构
[1] Trinity Coll Dublin, Sch Med, Dublin, Ireland
[2] Mater Misericordiae Univ Hosp, Dept Trauma & Orthopaed Surg, Dublin, Ireland
来源
PLOS ONE | 2024年 / 19卷 / 06期
关键词
FUNCTIONAL OUTCOMES;
D O I
10.1371/journal.pone.0304148
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Weber Type B fractures often arise from external rotation with the foot supinated or pronated. Altered tibiofibular joint kinematics in Weber B fractures are responsible for syndesmotic damage seen in Weber B fractures. Weber B fractures are managed using open reduction and internal fixation if displaced. The syndesmosis is injured in up to 40% of cases resulting in an unstable injury with a syndesmotic diastasis. This systematic review aimed to evaluate the current literature on syndesmotic fixation in Weber B fractures, assess the outcomes and complications of syndesmotic fixation and assess the necessity of syndesmotic fixation in Weber B fractures. A search was carried out on the EMBASE, PubMed and CINAHL databases and eight studies assessing the outcomes of syndesmotic fixations versus no syndesmotic fixation with 292 Weber B ankle fractures were included in this systematic review. Results showed significant heterogeneity so a narrative review was conducted. Results of these studies showed that functional, radiological, and quality-of-life outcomes and incidences of post-traumatic osteoarthritis in patients with syndesmotic screws were similar to those of patients not managed with syndesmotic screws. Only one favoured syndesmotic fixation in all cases of diastasis. As such, syndesmotic fixation with screws may not be necessary in the management of Weber B fractures. Screws are also associated with breakage, loosening, local irritation and infections. Suture button devices and antiglide fixation techniques appear to be valid alternatives to syndesmotic screws. It was found that there was no need for routine hardware removal unless the hardware was causing significant side effects for the patient.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Removal of Syndesmotic Screw After Fixation in Ankle Fractures: A Systematic Review
    Desouky, Omar
    Elseby, Amr
    Ghalab, Ahmed H.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [2] Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury
    R. Mohammed
    S. Syed
    S. Metikala
    S. A. Ali
    Indian Journal of Orthopaedics, 2011, 45 : 454 - 458
  • [3] Evaluation of the syndesmotic only fixation for Weber-C ankle fractures with syndesmotic injury: A comment
    Sanjay Meena
    Indian Journal of Orthopaedics, 2012, 46 : 253 - 253
  • [4] Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury
    Mohammed, R.
    Syed, S.
    Metikala, S.
    Ali, S. A.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (05) : 454 - 458
  • [5] Syndesmotic instability in Weber B ankle fractures: A clinical evaluation
    Stark, Erik
    Tornetta, Paul, III
    Creevy, William R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (09) : 643 - 646
  • [6] Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury: A comment
    Meena, Sanjay
    INDIAN JOURNAL OF ORTHOPAEDICS, 2012, 46 (02) : 253 - 253
  • [7] Tightrope fixation of syndesmotic injuries in Weber C ankle fractures: a multicentre case series
    Anand A.
    Wei R.
    Patel A.
    Vedi V.
    Allardice G.
    Anand B.S.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (4) : 461 - 467
  • [8] Should syndesmotic screws be removed after surgical fixation of unstable ankle fractures? A SYSTEMATIC REVIEW
    Dingemans, S. A.
    Rammelt, S.
    White, T. O.
    Goslings, J. C.
    Schepers, T.
    BONE & JOINT JOURNAL, 2016, 98B (11): : 1497 - 1504
  • [9] In Vivo Syndesmotic Overcompression After Fixation of Ankle Fractures With a Syndesmotic Injury
    Cherney, Steven M.
    Haynes, Jacob A.
    Spraggs-Hughes, Amanda G.
    McAndrew, Christopher M.
    Ricci, William M.
    Gardner, Michael J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (09) : 414 - 419
  • [10] Evaluation of the syndesmotic screw in low Weber C ankle fractures
    Kennedy, JG
    Soffe, KE
    Dalla Vedova, P
    Stephens, MM
    O'Brien, T
    Walsh, MG
    McManus, F
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (05) : 359 - 366