Ciprofloxacin Electrochemical Sensor Using Copper-Iron Mixed Metal Oxides Nanoparticles/Reduced Graphene Oxide Composite

被引:7
|
作者
Chuiprasert, Jedsada [1 ]
Srinives, Sira [2 ]
Boontanon, Narin [3 ]
Polprasert, Chongrak [4 ]
Ramungul, Nudjarin [5 ]
Karawek, Apisit [2 ]
Boontanon, Suwanna Kitpati [1 ,6 ]
机构
[1] Mahidol Univ, Fac Engn, Dept Civil & Environm Engn, Grad Program Environm & Water Resources Engn, Nakhon Pathom 73170, Thailand
[2] Mahidol Univ, Fac Engn, Dept Chem Engn, Nanocomposite Engn Lab NanoCEN, Nakhon Pathom 73170, Thailand
[3] Mahidol Univ, Fac Environm & Resource Studies, Nakhon Pathom 73170, Thailand
[4] Thammasat Univ, Fac Engn, Dept Civil Engn, Khlong Nueng 12120, Pathum Thani, Thailand
[5] Natl Met & Mat Technol Ctr, Natl Sci & Technol Dev Agcy, Khlong Luang 12120, Pathum Thani, Thailand
[6] Kyoto Univ, Grad Sch Global Environm Studies, Sakyo Ku, Kyoto 6068501, Japan
来源
ACS OMEGA | 2024年 / 9卷 / 22期
关键词
VOLTAMMETRIC DETERMINATION; ANTIBIOTICS; PERFORMANCE; HYBRID; NANOCOMPOSITES; ENHANCEMENT; ADSORPTION; OXIDATION;
D O I
10.1021/acsomega.3c06705
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The harmful effects of antibiotic proliferation on the environment and its persistent nature are urgent global problems. Ciprofloxacin (CIP) is a fluoroquinolone-class antibiotic agent used widely to treat pathogen-related diseases in humans and animals. Its excretion into surface water causes antibiotic resistance in microbes, resulting in difficult-to-treat or untreatable infectious diseases. This study developed a simple and efficient electrochemical sensor to detect CIP. Hydrothermal chemistry was utilized to synthesize an electrophotocatalytic composite of copper-iron mixed metal oxides (CIMMO) on reduced graphene oxide (rGO) (CIMMO/rGO). The composite was employed in an electrochemical sensor and exhibited outstanding performance in detecting CIP. The sensor was operated in differential pulse voltammetry (DPV) mode under light source illumination. The sensor yielded a linear response in the concentration range of 0.75 x 10-9-1.0 x 10-7 mol L-1 CIP and showed a limit of detection (LOD) of 4.74 x 10(-10) mol L-1. The excellent sensing performance of the composite is attributable to the synergic effects between CIMMO nanoparticles and rGO, which facilitate photoinduced electron-hole separation and assist in the indirect electrochemical reactions/interactions with CIP.
引用
收藏
页码:23172 / 23183
页数:12
相关论文
共 50 条
  • [1] A sensitive electrochemical sensor using an iron oxide/graphene composite for the simultaneous detection of heavy metal ions
    Lee, Sohee
    Oh, Jiseop
    Kim, Dongwon
    Piao, Yuanzhe
    TALANTA, 2016, 160 : 528 - 536
  • [2] Electrochemical sensor based on Sb nanoparticles/reduced graphene oxide for heavy metal determination
    Silva, Martin K. L.
    Cesarino, Ivana
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (13) : 3109 - 3123
  • [3] Reduced graphene oxide/zinc oxide composite as an electrochemical sensor for acetylcholine detection
    Pitiphattharabun, Siraprapa
    Auewattanapun, Krittin
    Htet, Thura Lin
    Thu, Myo Myo
    Panomsuwan, Gasidit
    Techapiesancharoenkij, Ratchatee
    Ohta, Jun
    Jongprateep, Oratai
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [4] Determination of glucose by molecularly imprinted electrochemical sensor based on reduced graphene oxide-copper nanoparticles
    Peng, Youyuan
    Zhang, Qing
    Chinese Journal of Analysis Laboratory, 2022, 41 (11) : 1297 - 1301
  • [5] Electrochemical properties and electrocatalytic activity of conducting polymer/copper nanoparticles supported on reduced graphene oxide composite
    Ehsani, Ali
    Jaleh, Babak
    Nasrollahzadeh, Mahmoud
    JOURNAL OF POWER SOURCES, 2014, 257 : 300 - 307
  • [6] Electrochemical Sensor Based on Graphene Oxide/Iron Nanoparticles for the Analysis of Quercetin
    Akyildirim, Onur
    Medetalibeyoglu, Hilal
    Manap, Sevda
    Beytur, Murat
    Tokali, Feyzi Sinan
    Yola, Mehmet Lutfi
    Atar, Necip
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (09): : 7743 - 7753
  • [7] Electrochemical H2O2 Sensor Based on Graphene Oxide-Iron Oxide Nanoparticles Composite
    Bas, Salih Zeki
    Ozmen, Mustafa
    Yildiz, Salih
    PROCEEDINGS OF THE 2017 IEEE 7TH INTERNATIONAL CONFERENCE NANOMATERIALS: APPLICATION & PROPERTIES (NAP), 2017,
  • [8] An electrochemical sensor based on reduced graphene oxide and copper sulfide hollow nanospheres
    Wang, Suiping
    Han, Zheng
    Li, Yafei
    Peng, Renfu
    Feng, Bo
    RSC ADVANCES, 2015, 5 (130): : 107318 - 107325
  • [9] An electrochemical sensor based on reduced graphene oxide/gold nanoparticles modified electrode for determination of iron in coastal waters
    Zhu, Yun
    Pan, Dawei
    Hu, Xueping
    Han, Haitao
    Lin, Mingyue
    Wang, Chenchen
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 1 - 7
  • [10] Graphitic Carbon Nitride/Copper-Iron Oxide Composite for Effective Fenton Degradation of Ciprofloxacin at Near-Neutral pH
    Ding, Qiqi
    Khan, Wasim U.
    Lam, Frank L. Y.
    Zhang, Yongqing
    Zhao, Shuaifei
    Yip, Alex C. K.
    Hu, Xijun
    CHEMISTRYSELECT, 2020, 5 (27): : 8198 - 8206