Effect of Gentamicin Sulfate and Polymeric Polyethylene Glycol Coating on the Degradation and Cytotoxicity of Iron-Based Biomaterials

被引:0
|
作者
Petrakova, Martina [1 ]
Gorejova, Radka [1 ]
Shepa, Jana [1 ]
Macko, Jan [1 ]
Kupkova, Miriam [2 ]
Micusik, Matej [3 ]
Balaz, Matej [4 ]
Hajduckova, Vanda [5 ]
Hudecova, Patricia [5 ]
Kozar, Martin [6 ]
Siskova, Barbora [6 ]
Saha, Petr [7 ]
Orinakova, Renata [1 ,7 ]
机构
[1] P J Safarik Univ Kosice, Dept Phys Chem, Kosice 04101, Slovakia
[2] Slovak Acad Sci, Inst Mat Res, Kosice 04001, Slovakia
[3] Slovak Acad Sci, Inst Polymers, Bratislava 84541, Slovakia
[4] Slovak Acad Sci, Inst Geotech, Kosice 04001, Slovakia
[5] Univ Vet Med & Pharm Kosice, Dept Microbiol & Immunol, Kosice 04181, Slovakia
[6] Univ Vet Med & Pharm Kosice, Small Anim Clin, Kosice 04001, Slovakia
[7] Tomas Bata Univ Zlin, Univ Inst, Ctr Polymer Syst, Zlin 76001, Czech Republic
来源
ACS OMEGA | 2024年 / 9卷 / 25期
关键词
COMPOSITE BONE-CEMENT; ANTIBACTERIAL EFFICACY; ORTHOPEDIC IMPLANTS; CORROSION; DELIVERY; METALS; SCAFFOLDS;
D O I
10.1021/acsomega.4c01002
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The work is focused on the degradation, cytotoxicity, and antibacterial properties, of iron-based biomaterials with a bioactive coating layer. The foam and the compact iron samples were coated with a polyethylene glycol (PEG) polymer layer without and with gentamicin sulfate (PEG + Ge). The corrosion properties of coated and uncoated samples were studied using the degradation testing in Hanks' solution at 37 degrees C. The electrochemical and static immersion corrosion tests revealed that the PEG-coated samples corroded faster than samples with the bioactive PEG + Ge coating and uncoated samples. The foam samples corroded faster compared with the compact samples. To determine the cytotoxicity, cell viability was monitored in the presence of porous foam and compact iron samples. The antibacterial activity of the samples with PEG and PEG + Ge against Escherichia coli CCM 3954 and Staphylococcus aureus CCM 4223 strains was also tested. Tested PEG + Ge samples showed significant antibacterial activity against both bacterial strains. Therefore, the biodegradable iron-based materials with a bioactive coating could be a suitable successor to the metal materials studied thus far as well as the materials used in the field of medicine.
引用
收藏
页码:27113 / 27126
页数:14
相关论文
共 20 条
  • [1] Effect of Gentamicin-Loaded Calcium Phosphate Coating and Polymeric Coating on the Degradation Properties of Biodegradable Iron-Based Biomaterials
    Petrakova, Martina
    Gorejova, Radka
    Shepa, Jana
    Macko, Jan
    Kupkova, Miriam
    Petrus, Ondrej
    Balaz, Matej
    Sopcak, Tibor
    Micusik, Matej
    Kozar, Martin
    Hajduckova, Vanda
    Orinakova, Renata
    ACS OMEGA, 2024, 9 (49): : 48299 - 48314
  • [2] Antibacterial polymeric coating based on polypyrrole and polyethylene glycol on a new alloy TiAlZr
    Ungureanu, Camelia
    Pirvu, Cristian
    Mindroiu, Mihaela
    Demetrescu, Ioana
    PROGRESS IN ORGANIC COATINGS, 2012, 75 (04) : 349 - 355
  • [3] EFFECT OF POLYETHYLENE GLYCOL COATING ON BIODISTRIBUTION OF ICG-LOADED POLYMERIC NANOCAPSULES IN MICE
    Bahmani, Baharak
    Gupta, Sharad
    Anvari, Bahman
    LASERS IN SURGERY AND MEDICINE, 2011, 43 : 908 - 908
  • [4] Polyethylene Glycol-Phase Fischer-Tropsch Synthesis over an Iron-Based Nanocatalyst
    Cheng Xiaofan
    Wu Baoshan
    Xiang Hongwei
    Li Yongwang
    CHINESE JOURNAL OF CATALYSIS, 2010, 31 (05) : 579 - 585
  • [5] Effect of copper on zerovalent iron-based oxidation for the degradation of trichloroethylene
    Choi, Kyunghoon
    Lee, Woojin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [6] Gaseous toluene heterogeneous oxidative degradation by iron-based hypercrosslinked polymeric resin LXQ-10
    Du, Zhaohui
    Yuan, Ying
    Zhou, Changsong
    Li, Wenrui
    Wang, Hao
    Wu, Hao
    Zhang, Zhen
    Yang, Hongmin
    FUEL, 2023, 344
  • [7] Study of the Corrosion Mechanism of Iron-Based Amorphous Composite Coating with Alumina in Sulfate-Reducing Bacteria Solution
    Chu, Zhenhua
    Shi, Haonan
    Xu, Fa
    Xu, Jingxiang
    Zheng, Xingwei
    Wang, Fang
    Zhang, Zheng
    Hu, Qingsong
    COATINGS, 2022, 12 (11)
  • [8] Effect of gas nitriding on microhardness and microstructure of laser cladding iron-based alloy coating
    Yang, Gaolin
    Pan, Lingyu
    Deng, Jiake
    Yong, Zhao
    Zhang, Qunli
    Yao, Jianhua
    JOURNAL OF LASER APPLICATIONS, 2025, 37 (02)
  • [9] Effect of aluminoxane on molecular weight and molecular weight distribution of polyethylene prepared by an iron-based catalyst
    Wang, Q
    Li, LD
    POLYMER INTERNATIONAL, 2004, 53 (10) : 1473 - 1478
  • [10] Effect of niobium on the microstructure and wear resistance of iron-based alloy coating produced by plasma cladding
    Zhang, Limin
    Sun, Dongbai
    Yu, Hongying
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2008, 490 (1-2): : 57 - 61