An Off-Chip Capacitance Biosensor Based on Improved Cole-Cole Model for the Detection of Trimethylamine N-Oxide in Early Cardiovascular Disease

被引:0
|
作者
Lin, Wei-Cheng [1 ,2 ]
Lo, Chi-Jen [3 ,4 ]
Cheng, Mei-Ling [4 ,5 ]
Zeng, Ren-Jie [1 ]
Hsieh, Yun-Yu [1 ]
Hou, Peng-Ru [1 ]
Yeh, Chun-Wei [1 ]
Hsieh, Chun-Ting [1 ]
Chang, Ming-Chiu [1 ]
Liao, Chien-Hung [2 ]
机构
[1] Chang Gung Univ, Dept Elect Engn, Taoyuan 333, Taiwan
[2] Chang Gung Mem Hosp, Dept Trauma & Emergency, Taoyuan 333, Taiwan
[3] Chang Gung Univ, Hlth Aging Res Ctr, Metabol Core Lab, Taoyuan 333, Taiwan
[4] Chang Gung Mem Hosp, Clin Metabol Core Lab, Taoyuan 333, Taiwan
[5] Chang Gung Univ, Coll Med, Hlth Aging Res Ctr, Dept Biomed Sci,Metabol Core Lab, Taoyuan 333, Taiwan
关键词
Sensors; Electrodes; Capacitance; Biosensors; Enzymes; Ions; Catalysis; Biosensor; capacitance; metabolism; trimethylamine N-oxide (TMAO); HUMAN PLASMA; CHOLINE; BETAINE; MICROBIOME; MS/MS;
D O I
10.1109/JSEN.2024.3368409
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, we demonstrated an off-chip capacitance array biosensor with the limit of detection 1 mu m of trimethylamine N-oxide (TMAO) to diagnose chronic metabolism disease in urine. Based on the improved Cole-Cole model, the parameters of R _catalyzed and C _catalyzed and R-p _catalyzed can predict the catalytic resistance of enzyme and redox effects of the analyte and identify the ac properties of ion strength due to enzymatic catalysis. With the investigation of the off-chip capacitance biosensor electrical field change with respect to pixel geometry and associated driving and sensing electrode width in a pixel, the proposed off-chip biosensor with readout system-on-chip (SoC) exhibits the high sensitivity of 21 ADC counts/ mu m (or 25 mV/ mu m ), response time of 0.1 s, repetition of 98.9%, and drift over time of 0.5 mV. The proposed off-chip biosensor can distinguish TMAO in phosphate buffered saline (PBS) solution from the tiny capacitance change of TMAO induced by enzyme TorA with a difference of 2.15%, and the measurements have been successfully verified with traditional cyclic-voltammetry (CV) method, which shows a difference of only 0.024%. The off-chip biosensor is designed to specifically detect TMAO by excluding the redox reactions of TMAO-specific enzyme TorA with creatine and creatinine in urine. This exclusion ensures that the biosensor focuses solely on TMAO, enhancing its specificity for accurate and reliable TMAO detection.
引用
收藏
页码:11515 / 11526
页数:12
相关论文
共 7 条
  • [1] Rapid and Direct Detection of Trimethylamine N-oxide Using an Off-Chip Capacitance Biosensor with Readout SoC for Early-Stage Thrombosis and Cardiovascular Disease
    Lin, Wei-Cheng
    Hsieh, Yun-Yu
    Ho, Peng-Ru
    Zeng, Ren-Jie
    Hsieh, Chun-Ting
    Chang, Ming-Chiu
    Yeh, Chun-Wei
    Lo, Chi-Jen
    Cheng, Mei-Ling
    Liao, Chien-Hung
    ACS SENSORS, 2024, 9 (02) : 638 - 645
  • [2] Pixel array-based urine biosensor for detection of trimethylamine N-oxide and glucose for early detection of diabetic kidney disease
    Yu, Mei-Ching
    Lo, Chi-Jen
    Lin, Wei-Cheng
    Yen, Wei-Lun
    Hsieh, Yun-Yu
    Chen, Bing-Hong
    Lo, Fu-Sung
    ANALYTICA CHIMICA ACTA, 2025, 1353
  • [3] Design and Optimization of a Two-Component TorRST-Based Biosensor for Detection and Degradation of Trimethylamine N-Oxide
    Zhang, Jian
    Xu, Jianping
    Yin, Jinyan
    Wang, Xiaotong
    Qi, Qingsheng
    Wang, Qian
    ACS SYNTHETIC BIOLOGY, 2025, 14 (02): : 553 - 563
  • [4] Longitudinal Plasma Measures of Trimethylamine N-Oxide and Risk of Atherosclerotic Cardiovascular Disease Events in Community-Based Older Adults
    Lee, Yujin
    Nemet, Ina
    Wang, Zeneng
    Lai, Heidi T. M.
    Otto, Marcia C. de Oliveira
    Lemaitre, Rozenn N.
    Fretts, Amanda M.
    Sotoodehnia, Nona
    Budoff, Matthew
    DiDonato, Joseph A.
    McKnight, Barbara
    Tang, W. H. Wilson
    Psaty, Bruce M.
    Siscovick, David S.
    Hazen, Stanley L.
    Mozaffarian, Dariush
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (17):
  • [5] Gut Microbiota-Dependent Trimethylamine N-Oxide Pathway Associated with Cardiovascular Risk in Children with Early-Stage Chronic Kidney Disease
    Hsu, Chien-Ning
    Lu, Pei-Chen
    Lo, Mao-Hung
    Lin, I-Chun
    Chang-Chien, Guo-Ping
    Lin, Sufan
    Tain, You-Lin
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2018, 19 (12)
  • [6] Serum gut microbe-dependent trimethylamine N-oxide improves the prediction of future cardiovascular disease in a community-based general population
    Zheng, Liqiang
    Zheng, Jia
    Xie, Yanxia
    Li, Zhao
    Guo, Xiaofan
    Sun, Guozhe
    Sun, Zhaoqing
    Xing, Fuguo
    Sun, Yingxian
    ATHEROSCLEROSIS, 2019, 280 : 126 - 131
  • [7] Investigation of electrocatalysis for tiered-tower micro-electro-mechanical-system-based biosensors: application in the early detection of the thrombosis factor trimethylamine N-oxide
    Lin, Wei-Cheng
    Chou, Shang-Chun
    Yen, Wei-Lun
    Hsieh, Yun-Yu
    Hsieh, Chun-Ting
    NANOSCALE, 2024, 16 (42) : 19897 - 19910