Is central line type an independent risk factor of central line-associated bloodstream infection in a neonatal intensive care unit population? Experiences at a pediatric hospital in South Texas

被引:0
|
作者
Durant, Danielle J. [1 ,2 ]
Fallwell, Nancy [3 ]
Martinez, Lesley [3 ]
Guerrazzi-Young, Claudia [4 ]
机构
[1] Texas A&M Univ, Coll Nursing & Hlth Sci, Corpus Christi, TX 78412 USA
[2] Westat Corp, Behav Hlth & Hlth Policy Practice, Rockville, MD 20850 USA
[3] Driscoll Childrens Hosp, Infect Prevent & Control Dept, Corpus Christi, TX USA
[4] Belmont Univ, Jack C Massey Coll Business, Nashville, TN USA
关键词
PROPENSITY SCORE; CATHETER;
D O I
10.1017/ash.2023.534
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Central line-associated bloodstream infection (CLABSI) causes significant harm in neonatal intensive care unit (NICU) patients. However, data regarding risk factors and prevention strategies for CLABSI in NICU patients is limited. Objective: To examine risk factors for CLABSI in a NICU population, with particular interest in central line type and site placement. Design: Retrospective case-control study. Setting: NICU (Level IV, 67 bed) at a pediatric hospital in South Texas. Participants: All central line insertions and subsequent CLABSI cases were extracted from the EHR for NICU admissions occurring from January 1, 2018, to November 3, 2022 (N = 1,356), along with potential CLABSI risk factors. Methods: Central line insertions resulting in CLABSI (N = 35) were compared to instances without CLABSI (N = 1,321) using bivariate and multivariate analysis, with propensity score matching. Results: Multivariate risk factors include implantable device (odds ratio [OR] = 14.5, P < .001), neck site placement (OR = 7.2, P < .001), and device dwell time (OR = 5.6, P = .001), as well as years 2021 (OR = 5.1, P = .017) and 2022 (OR = 5.9, P = .011). This indicates the odds of contracting CLABSI are 14.5 times higher when an implantable central line is used compared to the reference category (PICC devices). When cases are paired with matched controls, likelihood of CLABSI is 7.1% higher in patients with an implantable device than in similar patients with other central lines (p = 0.034). Conclusions: Implantable central lines are an independent risk factor for CLABSI in NICU patients at this facility.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Risk factors for central line-associated bloodstream infection in a pediatric cardiac intensive care unit
    Costello, John M.
    Graham, Dionne A.
    Morrow, Debra Forbes
    Potter-Bynoe, Gail
    Sandora, Thomas J.
    Laussen, Peter C.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2009, 10 (04) : 453 - 459
  • [2] Central Line-Associated Bloodstream Infection in Neonatal Intensive Care Units
    Blanchard, Ana C.
    Fortin, Elise
    Rocher, Isabelle
    Moore, Dorothy L.
    Frenette, Charles
    Tremblay, Claude
    Quach, Caroline
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2013, 34 (11): : 1167 - 1173
  • [3] Incidence of central line-associated bloodstream infection in an intensive care unit
    Espiau, M.
    Pujol, M.
    Campins-Marti, M.
    Planes, A. M.
    Pena, Y.
    Balcells, J.
    Roqueta, J.
    [J]. ANALES DE PEDIATRIA, 2011, 75 (03): : 188 - 193
  • [4] Risk factors for central line-associated bloodstream infection in a pediatric cardiac intensive care unit.
    Costello, John M.
    Graham, Dionne A.
    Morrow, Debra F.
    Poner-Bynoe, Gail
    Sandora, Thomas J.
    Laussen, Peter C.
    [J]. CRITICAL CARE MEDICINE, 2007, 35 (12) : A262 - A262
  • [5] Risk Factors for Central Line-Associated Bloodstream Infection in Pediatric Intensive Care Units
    Wylie, Matthew C.
    Graham, Dionne A.
    Potter-Bynoe, Gail
    Kleinman, Monica E.
    Randolph, Adrienne G.
    Costello, John M.
    Sandora, Thomas J.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2010, 31 (10): : 1049 - 1056
  • [6] Epidemiology of Central Line-Associated Bloodstream Infections in the Pediatric Intensive Care Unit
    Niedner, Matthew F.
    Huskins, W. Charles
    Colantuoni, Elizabeth
    Muschelli, John
    Harris, J. Mitchell, II
    Rice, Tom B.
    Brilli, Richard J.
    Miller, Marlene R.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2011, 32 (12): : 1200 - 1208
  • [7] Central Line-Associated Bloodstream Infection Risk Factors in a Pediatric Population
    Trembath, Hannah E.
    Caruso, Deanna M.
    McLean, Sean E.
    Akinkuotu, Adesola C.
    Hayes Dixon, Andrea A.
    Phillips, Michael R.
    [J]. AMERICAN SURGEON, 2024, 90 (01) : 69 - 74
  • [8] Central Line-Associated Bloodstream Infection: Not Just an Intensive Care Unit Problem
    Whited, Alyssa
    Lowe, Janell M.
    [J]. CLINICAL JOURNAL OF ONCOLOGY NURSING, 2013, 17 (01) : 21 - 24
  • [9] Risk factors for recurrent central line-associated bloodstream infections in a pediatric intensive care unit
    Isguder, Rana
    Devrim, Ilker
    Ceylan, Gokhan
    Kara, Ahu
    Gulfidan, Gamze
    Agin, Hasan
    [J]. TURKISH JOURNAL OF MEDICAL SCIENCES, 2017, 47 (04) : 1128 - 1136
  • [10] Central line-associated bloodstream infection in infants admitted to a level lll neonatal intensive care unit
    Nielsen, Camilla Littau
    Zachariassen, Gitte
    Holm, Kristina Garne
    [J]. DANISH MEDICAL JOURNAL, 2022, 69 (05):