A Dual-Mode Spectrophotometric and Fluorescent Probe Based on Lignin-Derived Carbon Dots for the Detection of Atorvastatin Calcium in a Bulk Powder and a Commercial Product

被引:0
|
作者
Aldakhil, Fatemah [1 ]
Alarfaj, Nawal A. [1 ]
Al-Tamimi, Salma A. [1 ]
El-Tohamy, Maha F. [1 ]
机构
[1] King Saud Univ, Coll Sci, Dept Chem, POB 22452, Riyadh 11495, Saudi Arabia
关键词
Atorvastatin; Carbon quantum dots; Green chemistry; Fluorescent; Dual-mode probe; QUANTUM DOTS;
D O I
10.1007/s10895-024-03745-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recently, dual-mode techniques have garnered considerable attention and have been shown to be effective approaches for biomedical analysis and environmental monitoring. A novel and simple dual-mode spectrophotometric and fluorometric probe based on lignin-derived carbon dots (LCDs) was developed to detect atorvastatin calcium (ATS) in a bulk powder and its commercial product. The synthesized LCDs exhibit exceptional fluorescence characteristics and are highly soluble in water while maintaining reasonable stability. The average particle size of the LCDs was 3.42 +/- 1.03 nm. The characterization of the produced LCDs indicated a structure resembling graphene oxide with the presence of several functional groups. The developed LCDs show a good fluorescence quantum yield of 32.2%. The fluorescence of the LCDs is quenched by ATS at an emission wavelength of 315 nm after excitation at 275 nm through dynamic and static quenching mechanisms. The optimal reaction conditions for the dual-mode reaction were a pH of 9 and 0.05 mL of the LCDs, which were measured after 3 min at 30 degrees C by spectrophotometry, followed by 7 min at 20 degrees C by fluorometric methods. According to the spectrophotometric results, the response of ATS was linear in the range of 4.0-100.0 mu g/mL, while according to the fluorometric results, the dynamic range was 3.0-50.0 mu g/mL. The limits of detection (LODs) and the limits of quantification (LOQs) were 0.97 mu g/mL and 2.95 mu g/mL for the fluorometric method, respectively. The nanoprobe effectively analyzed ATS in medication samples and yielded good results.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A dual-mode fluorescent probe based on carbon dots for detecting solution polarity
    Duan, Tingting
    Lu, Yanhong
    Ma, Ting
    Wang, Jing
    Xie, Tong
    Fan, Qi
    Wang, Zhengliang
    Wang, Qin
    Rong, Meizhu
    Yang, Peizhi
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 294
  • [2] Fluorescent and colorimetric dual-mode detection of Cu2+ based on carbon dots
    You, Yijun
    Li, Dan
    Chen, Zhuangzhuang
    Zhang, Xiangnan
    Hu, Yuxuan
    Ouyang, Shigen
    Li, Na
    MICROCHIMICA ACTA, 2024, 191 (09)
  • [3] Dual-mode nanoprobe for selective detection of arsenite based on yellow fluorescent carbon dots
    Jiang, Lei
    Yuan, Lin
    Xiang, Yingying
    Song, Fei
    Jiang, Wenjun
    Ji, Xiuling
    Tu, Yujiao
    DYES AND PIGMENTS, 2023, 215
  • [4] Carbon dots as a fluorescent ink and dual-mode probe for the efficient detection of doxycycline and Hg(II) ions
    Korah, Binila K.
    John, Neenamol
    John, Bony K.
    Mathew, Sneha
    Bijimol, D.
    Mathew, Beena
    JOURNAL OF MATERIALS RESEARCH, 2022, 37 (18) : 3060 - 3070
  • [5] Carbon dots as a fluorescent ink and dual-mode probe for the efficient detection of doxycycline and Hg(II) ions
    Binila K. Korah
    Neenamol John
    Bony K. John
    Sneha Mathew
    D. Bijimol
    Beena Mathew
    Journal of Materials Research, 2022, 37 : 3060 - 3070
  • [6] Sensitive and Selective Detection of Antibiotic D-Penicillamine Based on a Dual-Mode Probe of Fluorescent Carbon Dots and Gold Nanoparticles
    Ge, Hongwei
    Zhang, Kui
    Yu, Huan
    Yue, Ji
    Yu, Long
    Chen, Xinfeng
    Hou, Tianxin
    Alamry, Khalid A.
    Marwani, Hadi M.
    Wang, Suhua
    JOURNAL OF FLUORESCENCE, 2018, 28 (06) : 1405 - 1412
  • [7] Sensitive and Selective Detection of Antibiotic D-Penicillamine Based on a Dual-Mode Probe of Fluorescent Carbon Dots and Gold Nanoparticles
    Hongwei Ge
    Kui Zhang
    Huan Yu
    Ji Yue
    Long Yu
    Xinfeng Chen
    Tianxin Hou
    Khalid A. Alamry
    Hadi M. Marwani
    Suhua Wang
    Journal of Fluorescence, 2018, 28 : 1405 - 1412
  • [8] Yellow-green fluorescent carbon dots as fluorescent/colorimetric dual-mode probe for the detection of pH value and its application in fluorescent painting
    Yang, Yao
    Zhang, Shengrui
    Chinese Journal of Analysis Laboratory, 2022, 41 (09) : 1021 - 1024
  • [9] A dual-mode fluorescent probe based on perylene for the detection of Sn2+
    Ye, Xin-Lu
    Li, Ping
    Liu, Yu-Long
    Liang, Xiao-Min
    Yang, Liu
    INORGANIC CHEMISTRY COMMUNICATIONS, 2021, 130
  • [10] Fluorescent/Colorimetric Dual-Mode Discriminating Gln and Val Enantiomers Based on Carbon Dots
    Liao, Xuan
    Wu, Bingyan
    Li, Haixia
    Zhang, Mengtao
    Cai, Muzi
    Lang, Bozhi
    Wu, Zhizhen
    Wang, Fangling
    Sun, Jianong
    Zhou, Panpan
    Chen, Hongli
    Di, Duolong
    Ren, Cuiling
    Zhang, Haixia
    ANALYTICAL CHEMISTRY, 2023, 95 (39) : 14573 - 14581