Effect of High Intensity Wind Loads on Steel Poles Transmission Lines

被引:0
|
作者
Shehata, Ahmed [1 ]
Ahmed, Abdelrahman [1 ]
El Damatty, Ashraf [1 ,2 ]
机构
[1] Western Univ, London, ON, Canada
[2] Western Univ, WindEEE Res Inst, London, ON, Canada
关键词
Transmission lines; Steel poles; High intensity wind; Downbursts; Tornadoes; ASCE 74 (2020); PRESTRESSED CONCRETE POLES; FAILURE ANALYSIS; DOWNBURSTS; BEHAVIOR; TOWERS; DESIGN;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The vulnerability of transmission lines to high intensity wind (HIW) loads, such as downbursts and tornadoes, has been realized through several transmission lines failures around the world. Transmission poles are commonly used in urban and suburban high-voltage transmission lines. However, transmission poles can be more vulnerable to HIW loads than lattice transmission towers due to their limited redundancy. The study aims to investigate the sensitivity of steel poles transmission lines to downbursts and tornadoes. The critical load cases are determined by equating the peak straining actions due to HIW loads, to those obtained due to the synoptic wind and ice loads cases. HIW loads cases are calculated using the new provisions recently incorporated in ASCE 74 (2020) guidelines. The results of this study provide the magnitude of HIW loads beyond which the considered transmission poles are not safe, if they were designed to withstand only synoptic wind and ice loads cases without a margin of safety.
引用
收藏
页码:253 / 267
页数:15
相关论文
共 50 条
  • [1] Effect of High Intensity Wind Loads on Steel Poles Transmission Lines
    Shehata, Ahmed
    Ahmed, Abdelrahman
    El Damatty, Ashraf
    PROCEEDINGS OF THE CANADIAN SOCIETY OF CIVIL ENGINEERING ANNUAL CONFERENCE 2022, VOL 4, CSCE 2022, 2024, 367 : 253 - 267
  • [2] Nonlinear Performance of Steel Tube Tower in Ultra-High Voltage Transmission Lines under Wind Loads
    Li, Ruiqi
    Qi, Liangjie
    Dong, Yao-Rong
    Wang, Hui
    BUILDINGS, 2024, 14 (01)
  • [3] General Characteristics of Steel Poles used to support Transmission and Distribution Lines
    Torres, Andres
    2015 IEEE THIRTY FIFTH CENTRAL AMERICAN AND PANAMA CONVENTION (CONCAPAN XXXV), 2015,
  • [4] Reliability of power transmission lines subjected to extreme wind and ice loads
    Leira, BJ
    Holmås, T
    Hoiseth, KV
    Dahlslett, F
    Rolfseng, L
    Kulbotten, H
    STRUCTURAL SAFETY AND RELIABILITY, VOLS. 1-3, 1998, : 1449 - 1452
  • [5] Aerodynamic damping in cables of overhead transmission lines subjected to wind loads
    Carvalho, Hermes
    Correia, Jose
    de Jesus, Abilio
    Calcada, Rui
    WIND ENGINEERING, 2018, 42 (04) : 268 - 275
  • [6] Along-line wind loads and distribution patterns of transmission lines
    Shen G.-H.
    Bao Y.-N.
    Guo Y.
    Song G.
    Wang Y.-W.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2020, 54 (09): : 1658 - 1665
  • [7] Influence of Wind Loads on Transmission Lines Under Typical Ice Shapes
    Zhang Z.
    Zhou T.
    Jiang X.
    Hu J.
    Dianwang Jishu/Power System Technology, 2023, 47 (12): : 5247 - 5255
  • [8] LAWS OF DISTRIBUTION OF GLAZE AND WIND LOADS ON AERIAL TRANSMISSION LINES.
    Golikov, B.F.
    Soviet meteorology and hydrology, 1986, (09): : 79 - 83
  • [9] Passenger Transmission and Productiveness of Transit Lines with High Loads
    Bunker, Jonathan
    TRANSPORTATION RESEARCH RECORD, 2012, (2274) : 144 - 153
  • [10] Comparative Analysis of Transmission Poles Executed in Mild Steel and High Strength Steel
    Sousa, Joao
    Henriques, Jorge
    Barros, Rui
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHANICS AND CIVIL ENGINEERING, 2014, 7 : 88 - 93