Influence of Voxel Size on CBCT Images for Dental Implants Planning

被引:4
|
作者
Kehrwald, Ricardo [1 ]
de Castro, Hebert Sampaio [1 ]
Salmeron, Samira [1 ]
Matheus, Ricardo Alves [2 ]
Santaella, Gustavo Machado [3 ]
Queiroz, Polyane Mazucatto [4 ,5 ]
机构
[1] Inga Ctr Univ Maringa, Dept Dent, Area Implantol, Maringa, Parana, Brazil
[2] Univ Estadual Londrina, Dept Oral Med, Div Oral Radiol, Londrina, Parana, Brazil
[3] Univ Louisville, Dept Diag & Oral Hlth, Div Oral Radiol, Louisville, KY USA
[4] Inga Ctr Univ Maringa, Dept Dent, Div Oral Radiol, Area Oral Radiol, Maringa, Parana, Brazil
[5] Inga Univ Ctr, Dept Dent, Area Implantol, 6114 Rod PR 317, BR-87035510 Maringa, Parana, Brazil
关键词
cone beam computed tomography; dental implants; diagnosis; dimensional measurement accuracy; implant planning; jaw edentulous; mandible; BEAM COMPUTED-TOMOGRAPHY; LINEAR MEASUREMENTS; ROOT FRACTURES; ACCURACY; VIEW;
D O I
10.1055/s-0041-1736388
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective This study was developed to evaluate the influence of voxel size on bone measurements for implant planning. Materials and Methods The research was performed by using edentulous synthetic human mandibles with different levels of bone resorption. For each mandible, height and bone thickness were measured with a digital caliper. The PaX-i3d device was used to acquire the volumes of the five mandibles, with 50kVp, 4mA, and a voxel size of 0.08 mm. After the acquisition, the images were reconstructed in the software CS three-dimensional Imaging, with four different sizes of voxels: 0.1, 0.2, 0.3, and 0.4mm. All volumes were analyzed by a single evaluator who performed measurements to obtain bone height and thickness, using the reference points that were considered in obtaining the gold standard. The data were analyzed by ANOVA with a significance level of 5%. Results There was no significant difference in the measurements obtained with different voxel sizes, both for bone height measurements and bone thickness. There was no statistically significant difference in measurements in thickness in comparison to the gold standard. Conclusion When necessary, to measure height and bone thickness, it is possible to recommend voxel images of larger size (0.40 mm) without compromising the quality of the patient's clinical planning.
引用
收藏
页码:381 / 385
页数:5
相关论文
共 50 条
  • [1] Planning of dental implant size with digital panoramic radiographs, CBCT-generated panoramic images, and CBCT cross-sectional images
    Correa, Leticia Ruhland
    Spin-Neto, Rubens
    Stavropoulos, Andreas
    Schropp, Lars
    Dias da Silveira, Heloisa Emilia
    Wenzel, Ann
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (06) : 690 - 695
  • [2] Automatic simulated dental implants method with implant parameter estimation based on CBCT images
    Wang, Kai
    Liu, Jiaying
    Yang, Shuai
    Guo, Jing
    Ke, Yongzhen
    ENGINEERING COMPUTATIONS, 2023, 40 (9/10) : 2363 - 2385
  • [3] CBCT-based volume of simulated root resorption - influence of FOV and voxel size
    Da Silveira, P. F.
    Fontana, M. P.
    Oliveira, H. W.
    Vizzotto, M. B.
    Montagner, F.
    Silveira, H. L.
    Silveira, H. E.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (10) : 959 - 965
  • [4] Influence of Low-Dose Protocols of CBCT on Dental Implant Planning
    de Castro, Hebert Sampaio
    Kehrwald, Ricardo
    Matheus, Ricardo Alves
    Gomes, Amanda Farias
    Queiroz, Polyane Mazucatto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : 307 - 312
  • [5] INFLUENCE OF VOXEL SIZE ON EVALUATION OF TRABECULAR BONE MICROSTRUCTURE ON HUMAN MANDIBLES: A CBCT STUDY
    Bilgili, Ersen
    JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES, 2022, 6 (03): : 791 - 797
  • [6] Accuracy of CBCT images in the volumetric assessment of residual root canal filling material: Effect of voxel size
    Yilmaz, F.
    Sonmez, G.
    Kamburoglu, K.
    Koc, C.
    Ocak, M.
    Celik, H. H.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (08) : 1091 - 1098
  • [7] When should you use CBCT for dental implants?
    不详
    British Dental Journal, 2021, 231 (5) : 312 - 312
  • [8] When should you use CBCT for dental implants?
    不详
    BRITISH DENTAL JOURNAL, 2021, 231 (05) : 312 - 312
  • [9] Influence of CBCT-derived panoramic curve variability in the measurements for dental implant planning
    Adames, Cyntia
    Gaeta-Araujo, Hugo
    Franco, Ademir
    Soares, Mariana Quirino Silveira
    Junqueira, Jose Luiz Cintra
    Oenning, Anne Caroline
    ORAL RADIOLOGY, 2024, 40 (01) : 30 - 36
  • [10] Influence of CBCT-derived panoramic curve variability in the measurements for dental implant planning
    Cyntia Adames
    Hugo Gaêta-Araujo
    Ademir Franco
    Mariana Quirino Silveira Soares
    José Luiz Cintra Junqueira
    Anne Caroline Oenning
    Oral Radiology, 2024, 40 : 30 - 36