Isometric muscle torque in Chilean children and adolescents evaluated by manual maintenance dynamometry: a reliability study

被引:0
|
作者
Jorquera-Caceres, Ivonne [1 ,2 ]
Vega-Arriagada, Danayra [1 ]
Nunez-Gonzalez, Dannae [1 ]
Guzman-Munoz, Eduardo [1 ,2 ,3 ]
Castillo-Retamal, Marcelo [4 ]
Yuing-Farias, Tuillang [1 ,2 ]
de la Rosa, Francisco Jose Berral [5 ]
Mendez-Rebolledo, Guillermo [1 ,2 ,3 ]
机构
[1] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Santiago, Chile
[2] Univ Santo Tomas, Fac Salud, Nucleo Invest Kinesiol NIK, Santiago, Chile
[3] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Lab Invest Somatosensorial & Motora, Talca, Chile
[4] Univ Catolica Maule, Fac Ciencias Educ, Dept Ciencias Act Fis, Talca, Chile
[5] Univ Pablo Olavide, Grp Invest CTS 595, Seville, Spain
来源
ANDES PEDIATRICA | 2024年 / 95卷 / 03期
关键词
Adolescent; Child; Muscle Strength; Muscle Strength Dynamometer; HAND-HELD DYNAMOMETRY; BREAK TESTS; LOCOMOTOR CAPACITY; STRENGTH; INDIVIDUALS; EXTREMITY; MATURITY; VALUES;
D O I
10.32641/andespediatr.v95i3.4956
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The measurement of isometric muscle torque with hand-held dynamometry is a technique little studied in the pediatric setting for the evaluation of maximal isometric muscle strength. Objective: to determine the reliability of hand-held dynamometry to obtain the maximal isometric torque of upper and lower limb muscle groups in Chilean children and adolescents. Patients and Methods: Crosssectional study. Seventy-two participants aged between 7 and 15 years were selected from a school in Talca. Maximal isometric torque was recorded in 15 muscle groups of upper and lower limbs through hand-held dynamometry. Intra- and inter -rater evaluation was used, applying the intraclass correlation coefficient (ICC) to determine the reliability of the tests and Bland -Altman plots to evaluate concordance. Results: The results demonstrated good to excellent inter -rater reliability (ICC = 0.850.98) and intra-rater reliability (ICC = 0.87-0.98). Only two groups, hip extensors and abductors, showed good inter -rater reliability (ICC = 0.85 and ICC = 0.88, respectively); and one group, the ankle dorsiflexors, showed good intra-rater reliability (ICC = 0.87). 100% of the tests presented at least 95.8% inter- and intra-rater agreement on the Bland -Altman plots. Conclusion: The evaluation of isometric muscle torque using hand-held dynamometry is a reliable procedure for use in different growth periods.
引用
收藏
页码:252 / 262
页数:11
相关论文
共 50 条
  • [1] Hand-Held Dynamometry Isometric Torque Reference Values for Children and Adolescents
    Hebert, Luc J.
    Maltais, Desiree B.
    Lepage, Celine
    Saulnier, Joanne
    Crete, Melanie
    PEDIATRIC PHYSICAL THERAPY, 2015, 27 (04) : 414 - 423
  • [2] Isometric muscle strength in children and adolescents using Handheld dynamometry: reliability and normative data for the Brazilian population
    Tezo Daloia, Ligia Maria
    Leonardi-Figueiredo, Marisa Maia
    Martinez, Edson Zangiacomi
    Mattiello-Sverzut, Ana Claudia
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2018, 22 (06) : 474 - 483
  • [3] Commentary on "Hand-Held Dynamometry Isometric Torque Reference Values for Children and Adolescents"
    Masaracchio, Michael
    Comet, Sheryl
    PEDIATRIC PHYSICAL THERAPY, 2015, 27 (04) : 424 - 424
  • [4] INTRARATER RELIABILITY OF MANUAL MUSCLE TESTING AND DYNAMOMETRY
    HARROLD, JA
    KRISHNAN, RS
    SEAR, ML
    WADSWORTH, CT
    PHYSICAL THERAPY, 1984, 64 (05): : 736 - 736
  • [5] Isometric Muscle Strength in Youth Assessed by Hand-held Dynamometry: A Feasibility, Reliability, and Validity Study
    Hebert, Luc J.
    Maltais, Desiree B.
    Lepage, Celine
    Saulnier, Joanne
    Crete, Melanie
    Perron, Marc
    PEDIATRIC PHYSICAL THERAPY, 2011, 23 (03) : 289 - 299
  • [6] Commentary on "Isometric Muscle Strength in Youth Assessed by Hand-held Dynamometry: A Feasibility, Reliability, and Validity Study"
    Nervik, Deborah
    Nicols, Jennifer Parent
    PEDIATRIC PHYSICAL THERAPY, 2011, 23 (03) : 300 - 300
  • [7] Validity and Reliability of Handheld Dynamometry to Assess Isometric Hamstrings and Quadriceps Strength at Varying Muscle Lengths
    Baron, Margaux
    Divernois, Gilles
    Grandjean, Benoit
    Guex, Kenny
    JOURNAL OF SPORT REHABILITATION, 2024, 33 (04) : 267 - 274
  • [8] Evaluation of Hand Muscle Strength Using Manual Dynamometry: A Reliability and Validity Study of the Activ5 Instrument
    Pino-Ortega, Jose
    Carvajal-Espinoza, Rafael
    Becerra-Patino, Boryi A.
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [9] Assessing the Reliability of Handheld Dynamometry and Ultrasonography to Measure Quadriceps Strength and Muscle Thickness in Children, Adolescents, and Young Adults
    Rock, Kelly
    Nelson, Christa
    Addison, Odessa
    Marchese, Victoria
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2021, 41 (05) : 540 - 554
  • [10] Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke
    Mentiplay, Benjamin F.
    Tan, Dawn
    Williams, Gavin
    Adair, Brooke
    Pua, Yong-Hao
    Bower, Kelly J.
    Clark, Ross A.
    JOURNAL OF BIOMECHANICS, 2018, 75 : 171 - 175